![Unify OpenScape Cordless IP V2 Administrator Documentation Download Page 15](http://html2.mh-extra.com/html/unify/openscape-cordless-ip-v2/openscape-cordless-ip-v2_administrator-documentation_3779400015.webp)
P31003C1020M1000276A9, 01/2018
OpenScape Cordless IP V2, Administrator Documentation
15
Operation hints
Resetting base stations to factory settings via power procedure
3.1.4 DECT manager (with DECT)
3.2 Resetting base stations to factory settings via power procedure
The following describes the procedure to reset base stations to factory settings via power procedure. You can use
it, if it is not possible to reset the device
• via the web configurator ( p. 85), for instance because you have forgotten the password for the web
configurator or you are experiencing problems accessing the LAN
• via the key procedure ( p. 12), for instance because the devices are mounted in places that are difficult to
access.
Resetting the device to factory settings is performed by interrupting the boot process.
Remove the power supply from the device (unplug the LAN cable).
Replug the LAN cable . . . the reboot starts. If the boot process is not interrupted, the standard reboot is per-
formed.
Interrupt the boot procedure after 30 sec. at the earliest and 40 sec. at the latest.
LED 1 (left)
LED 2 (right)
Description
0.5 s 0.5 s 0.5 s 0.5 s
0.5 s
0.5 s
0.5 s
0.5 s
Not synchronised, DECT ready
Synchronised, DECT ready
Synchronised, system traffic,
no DECT traffic
Synchronised, DECT traffic
Synchronised, DECT overload
The following procedure only applies to base stations. For DECT manager/Integrator you need to use
one of the above procedures.
Once
The device is reset as Integrator/DECT manager with a dynamic IP settings.
Three times
The device is reset as base station.
Five times
The device is reset as Integrator/DECT manager with fixed IP settings.
This procedure resets all the settings you have made for the device. The procedure deletes the saved
data from the base stations and handsets. The base station's assignment to the DECT manager is
cancelled. Ongoing calls are cancelled. In the case of an Integrator/DECT manager the whole
configuration is reset.
To enable the restoration of your system configuration after a reset, you should regularly save the
configuration data to a file ( p. 84).