Uniflame nsg3902d Owner'S Manual Download Page 6

Outdoor LP Gas Barbecue Grill Model No. NSG3902D

Contact 1-800-762-1142 for assistance. Do not return to place of purchase.

page no.

Direct Cooking

1. Light burners per lighting instructions.

2. Set burners to desired level and allow temperature to be reached.

3. Place food directly over burners.

4. With lid open or closed, cook untill desired internal temperatures are acheived.

Indirect Cooking

Ideal for roasts and larger cuts of meat.

1. Remove cooking grid.

2. Place metal tray in center, on heat plates.

3. Replace cooking grid.

4. Light burners.

5.  Turn center burner off. Set ouside burners to desired level and allow temperature to 

be reached.

6. Place food on cooking grid, directly over metal tray.

7. With lid closed, cook until desired internal temperatures are achieved.

Tips For Better Cook Outs and Longer Product Life

1. Spray or coat cooking surfaces with vegetable oil before cooking to avoid sticking.

2. Place vegetables or delicate foods into aluminum foil pouches.

3.  Use a quality grill brush after each event to keep cooking surfaces clean and rust free.

4. Empty grease pan after every use.

CAUTION: Do not cover grill until it is completely cool to the touch.

Operating Side Burner

NOTE:   Side burner can be used while main burners are operating.

Never use side burner as a grill.

Lighting

1.  Open lid. 

Attempting to light the 

burner with the lid closed may 
cause an explosion!

  

2.  Make sure there are no 

obstructions of airflow to the gas 
unit. Spiders and insects can nest 
within and clog the burner / venturi 
tube at the orifice.  

A clogged 

burner tube can lead to a fire 
beneath the appliance.

3.  Control knob must be in the OFF 

position.

4. Turn on gas at LP gas tank.

5.  Push and turn control knob counterclockwise to HIGH.

6.  Press the electronic igniter button and hold for 5 seconds to light burner.

7.  If ignition does not occur in 5 seconds, turn burner control knob OFF, wait 5 minutes, 

and repeat lighting procedure.  

8.  If igniter does not light burner, use a lit match secured with the lighting rod provided 

to light burners manually. Position the lit match near side of the burner. 

Important:

 Always use the lighting rod provided when lighting burners with a match.

9.  After lighting, please observe the burner flame, make sure all burner ports are lit and 

flame height matches illustration. 

CAUTION: If burner flame goes out during operation, immediately 
turn the gas “OFF” and open lid to let the gas clear for about 5 
minutes before re-lighting. 

Turning Off

1.  Turn control knob clockwise to the OFF position.

2. Turn gas off at LP gas tank.

Cooking

1. Light burner.

2. Set burner to desired temperature

3. Place pan on center of grid.

4. Cook and adjust temperature as needed.

Operating Instructions

Checking for Leaks

Burner Connections

Make sure the regulator valve and hose 
connections are securely fastened to the 
burner and the tank.  

If your unit was assembled for you, visually 
check the connection between the burner 
pipe and orifice.  Make sure the burner 
pipe fits over the orifice.  

WARNING: Failure to inspect 
this connection or follow these 
instructions could cause a fire 
or an explosion which can cause 
death, serious bodily injury, or 
damage to property.  

Please refer to diagram for proper 
installation.  

If the burner pipe does not rest flush to 
the orifice, please contact 1.800.762.1142 
for assistance.

Tank/Gas Line Connection

Make 2-3 oz. of leak solution by mixing one 
part liquid dishwashing soap with three parts 
water.  

Make sure control knobs are off.  

 Turn LP gas tank ON at valve.

  Spoon leak check solution at all “x” locations

 If any bubbles appear turn LP gas tank OFF, 
reconnect and re-test. If you continue to see 
bubbles after several attempts, disconnect LP 
gas source and contact 1.800.762.1142 for 
assistance.

If no bubbles appear after one minute turn tank OFF, wipe away solution and proceed.

Operating Main Burners

Lighting

1.  Open lid. 

Attempting to light the 

burner with the lid closed may 
cause an explosion!

  

2.  Make sure there are no 

obstructions of airflow to the gas 
unit. Spiders and insects can nest 
within and clog the burner / venturi 
tube at the orifice.  

A clogged 

burner tube can lead to a fire 
beneath the appliance.

3.  All control knobs must be in the 

OFF position.

4. Turn on gas at LP gas tank.

5. Push and turn control knob counterclockwise to HIGH.

6.  Press the electronic igniter button and hold for 5 seconds to light burner.

7.  If ignition does not occur in 5 seconds, turn burner control knob OFF, wait 5 minutes, 

and repeat lighting procedure.  

8.  If igniter does not light burner, use a lit match secured with the lighting rod provided 

to light burners manually. Access the burners through the cooking grid and heat 
plates. Position the lit match near side of the burner. 

Important:

 Always use the lighting rod provided when lighting burners with a match.

9.  After lighting, observe the burner flame, make sure all burner ports are lit and flame 

height matches illustration. 

CAUTION: If burner flame goes out during operation, immediately 
turn the gas “OFF” and open lid to let the gas clear for about 5 
minutes before re-lighting. 

Turning Off

1.  Turn all control knobs clockwise to the OFF position one at a time.

2. Turn gas off at LP tank.

Initial Use

 

Before cooking on this grill for the first time, operate the grill for about 15 minutes with 
the lid closed and the gas turned on “HIGH.” This will “heat clean” the internal parts and 
dissipate odor from the manufacturing processes.

X

X

X

X

X

Main Burners

Gas Valve 
with orifice

Burner 
Venturi

Gas 
Connections

Side Burner

Gas Valve 
with orifice

Gas 
Connections

Burner 
Venturi

1/2"

12.7 mm

6.4mm

0mm

1/4"

0"

Burner

Main burner proper flame height.

Flame

0"

0 mm

3/8"

9.5 mm

3/4"

19 mm

Side burner proper flame height.

Burner

Flame

Summary of Contents for nsg3902d

Page 1: ...on of this product must conform to local codes In absence of local codes use the National Fuel Gas Code ANSI Z223 1 NFPA 54 CAN CGA B149 1 Natural Gas and Propane Installation Code Save these instructions for future reference If you are assembling this unit for someone else give this manual to him or her to read and save for future reference WARNING FOR YOUR SAFETY 1 Improper installation adjustme...

Page 2: ...east 21 inches 53 cm away from the grill at all times DO NOT use this grill or any gas product under any overhead or near any unprotected combustible constructions 26 It is essential to keep the grill s valve compartment burners and circulating air passages clean Inspect grill before each use 27 Do not alter grill in any manner 28 Do not use the grill unless it is COMPLETELY assembled and all part...

Page 3: ... bar to cart by using 2 sets of extra large screws F lock washers L and extra large washers K Note cart is shown upside down Step 3 Attach doors and basket A Install right and left doors by placing bottom pin into hole in cart depress top spring pin and snap top pin into hole in cross bar Note Spring pins are located on top of doors B Hang basket on left door Step 5 Insert bolts Insert 4 bolts G i...

Page 4: ... side shelf using medium screw D lock washer L and medium washer J Note view is from rear Note view is from below and rear Note view is from right side Step 10 Secure side shelves Secure side shelves to grill body using 2 small screws C Note view is from under right side shelf Step 13 Insert cooking grids and warming rack A Insert cooking grids B Place warming rack with legs down onto sides of gri...

Page 5: ...ockwise Step 18 Completed Congratulations your assembly is now complete Read Operating Instructions before proceeding Installing LP Gas Tank To operate you will need 1 precision filled standard grill LP gas tank 20 with external valve threads Insert LP Gas Tank Place precision filled LP gas tank upright into hole in grill body so it is arranged for vapor withdrawal Secure LP Gas Tank Secure tank b...

Page 6: ...ecurely fastened to the burner and the tank If your unit was assembled for you visually check the connection between the burner pipe and orifice Make sure the burner pipe fits over the orifice WARNING Failure to inspect this connection or follow these instructions could cause a fire or an explosion which can cause death serious bodily injury or damage to property Please refer to diagram for proper...

Page 7: ...arranty shall be limited to the repair or replacement of parts which prove defective under normal use and service and which Vendor shall determine in its reasonable discretion upon examination to be defective Before returning any parts you should contact Vendor s Customer Service Department using the contact information listed below If Vendor confirms after examination a defect covered by this Lim...

Page 8: ...flow safety device by turning off knobs and LP cylinder valve Disconnect regulator Turn burner control knobs to HIGH Wait 1 minute Turn burner control knobs off Reconnect regulator and leak check connections Turn LP cylinder valve on slowly wait 30 seconds and then light grill Irregular flame pattern flame does not run the full length of burner Burner ports are clogged or blocked Clean burner port...

Page 9: ...ew G Bolt 8 pcs M6x20 Nickel Plated Hex Head Bolt H Small Washer 1 pc ø4 3 Nickel Plated Washer I Medium Washer 1 pcs ø5 4 Nickel Plated Washer J Large Washer 2 pcs ø6 4 Nickel Plated Washer K Extra Large Washer 6 pcs ø6 4 Nickel Plated Washer L Lock Washer 8 pcs ø6 5 Nickel Plated Lock Washer M AA Battery 1 pc Tools Included N Screwdriver 1 pc Not shown at actual size Exploded View 1 Lid Assembly...

Page 10: ... niquelada ø4 3 I Arandela mediana 1 Arandela niquelada ø5 4 J Arandela grande 2 Arandela niquelada ø6 4 K Arandela extra grande 6 Arandela niquelada ø6 4 L Arandela de cierre 8 Arandela de cierre niquelada ø6 5 M Pila AA 1 Herramientas incluidas N Destornillador 1 Esta pieza no se ve a tamaño real Diagrama de Explosión 1 Conjunto de tapa 2 Conjunto del cuerpo de la parrilla 3 Rejilla de calentami...

Page 11: ...la bombona de propano líquido Desconecte el regulador Gire las perillas de control del quemador a la posición HIGH Espere 1 minuto Gire las perillas de control del quemador a la posición off Vuelva a conectar las conexiones del regulador y del dispositivo de comprobación de fugas Abra lentamente la válvula de la bombona de propano líquido espere 30 segundos y a continuación encienda la parrilla Fa...

Page 12: ...spa Registro del Producto Sírvase registrar su unidad inmediatamente visitando nuestro sitio de internet www BlueRhino com o llamando al 1 800 762 1142 Garantia Limitada Blue Rhino Sourcing LLC el fabricante garantiza al comprador original al detal de esta parrilla que si la unidad se arma y opera de acuerdo con las instrucciones impresas que la acompañan y por un período de un 1 año a partir de l...

Page 13: ...uemador se apaga durante el funcionamiento cierre el gas OFF inmediatamente y abra la tapa durante 5 minutos para dejar que la zona quede despejada de gas antes de volver a encenderlo Instrucciones de Operación Comprobar si Hay Fugas Conexiones del quemador Asegúrese de conectar adecuadamente la válvula del regulador al quemador y la bombona Si alguien armó la unidad para usted verifique visualmen...

Page 14: ...reloj Paso 18 Terminado Felicitaciones el armado ha terminado Lea las instrucciones de operación antes de seguir adelante Instalación de la bombona de propano LP Para operar la unidad necesitará una bombona de 20 libras de gas propano licuado llenada con precisión para parrilla estándar Inserte la bombona de propano Coloque una bombona de gas LP llenada con precisión en posición vertical en la abe...

Page 15: ... mediano D arandela de cierre L y arandela media J Paso 10 Asegure los estantes laterales Asegure los estantes laterales en el cuerpo de la parrilla usando 2 tornillos pequeños C NOTA Vista desde abajo del estante del lado derecho Paso 13 Inserte las parrillas de cocción y la rejilla de calentamiento A Inserte las parrillas de cocción B Coloque la rejilla de calentamiento con las patas hacia abajo...

Page 16: ...TA El carro se muestra boca arriba Paso 3 Instale las puertas y la canasta A Instale las puertas derecha e izquierda colocando el perno de abajo en el hueco en el carro oprima el resorte del perno de arriba y conecte a presión la parte de arriba del perno en la barra de travesaño NOTA Los pernos de resorte se encuentran en la parte de arriba de las puertas B Cuelgue la canasta en la puerta izquier...

Page 17: ...omento NO use esta parrilla debajo de aleros o cerca de construcciones combustibles que no estén debidamente protegidas 26 Es fundamental mantener limpio el compartimiento de la válvula de la parrilla los quemadores y los conductos de aire circulante Inspeccione la parrilla antes de cada uso 27 No altere la parrilla de ninguna forma 28 No utilice la parrilla a menos que esté COMPLETAMENTE montada ...

Page 18: ...xplosión y elementos de ferretería Apéndice A El uso e instalación de este producto ha de realizarse de acuerdo con los códigos locales Si no existen códigos locales use las normas siguientes Código Nacional para Gas y Combustibles ANSI Z223 1 NFPA 54 CAN CGA B149 1 Código de Instalación de Propano y Gas Natural Conserve estas instrucciones para futuras consultas Si está montando esta unidad para ...

Reviews: