Troubleshooting

Problem

Possible Cause

Prevention/Cure

Burner will not light using ignitor

Battery needs to be changed.

Replace the AA battery. (Follow assembly step for inserting 
battery.

Wires or electrode covered with cooking residue.

Clean wire and/or electrode with rubbing alcohol.

Electrode and burners are wet.

Wipe dry with cloth.

Electrode cracked or broken - sparks at crack.

Replace electrode.

Wire loose or disconnected.

Reconnect wire or replace electrode/wire assembly.

Wire is shorting (sparking) between ignitor and electrode.

Replace ignitor wire/electrode assembly.

Bad ignitor.

Replace ignitor.

Burner will not light with match

No gas flow.

Check if LP gas tank is empty. If empty, replace or refill. If LP 
gas tank is not empty, refer to “Sudden drop in gas flow or 
reduced flame height”. 

Coupling nut and regulator not fully connected.

Turning the coupling nut about one-half to three quarters 
additional turn until solid stop. Tighten by hand only-do not use 
tools.

Obstruction of gas flow.

Clear burner tubes. Check for bent or kinked hose.

Disengagement of burner to valve.

Reengage burner and valve.

Spider webs or insect nest in venturi.

Clean venturi.

Burner ports clogged or blocked.

Clean burner ports.

Sudden drop in gas flow or reduced flame height

Out of gas.

Replace or refill LP gas tank.

Excess flow; safety device may have been activated.

Turn control knobs to “OFF”. Wait 30 seconds and light grill. If 
flames are still too low, reset the excessive flow safety device 
by turning control knobs “OFF” and LP gas tank valve to 
“CLOSED”. Disconnect regulator. Turn control knobs to “HIGH”. 
Wait 1 minute. Turn control knobs to “OFF”. Reconnect regulator 
and leak check connections. Slowly turn LP gas tank valve 
to “OPEN”. Wait 30 seconds and then light grill per lighting 
instructions.

Irregular flame pattern, flame does not run the full length 
of burner.

Burner ports are clogged or blocked.

Clean burner ports.

Flame is yellow or orange.

New burner may have residual manufacturing oils.

Burn grill for 15 minutes with the lid closed

Spider webs or insect nest in venturi

Clean venturi.

Food residue, grease or seasoning salt on burner.

Clean burner.

Poor alignment of valve to burner venturi.

Assure burner venturi is properly engaged with valve.

Flame blow out

High or gusting winds.

Do not use grill in high winds.

Low on LP Gas.

Replace or refill LP gas tank.

Excess flow valve tripped.

Refer to “Sudden drop in gas flow or reduced flame height”.

Flare-up

Grease buildup.

Clean grill.

Excess fat in meat.

Trim fat from meat before grilling.

Excessive cooking temperature.

Adjust (lower) temperature accordingly.

Persistent grease fire.

Grease trapped by food buildup around burner system.

Turn control knobs to “OFF”. Turn LP gas tank valve to 
“CLOSED”. Leave lid in closed position and let fire burn out. 
After grill cools, remove and clean all parts.

Flashback (fire in burner tube(s)).

Burner and/or burner tubes are blocked.

Clean burner and/or burner tubes.

Inside of lid is peeling (like paint peeling).

The lid is stainless steel, not painted.

Baked on grease buildup has turned to carbon and is flaking off. 
Clean thoroughly.

For more assistance please visit us online at www.bluerhino.com or call 1.800.762.1142.

Summary of Contents for GBC920W1

Page 1: ...al to him or her to read and save for future reference WARNING FOR YOUR SAFETY For Outdoor Use Only outside any enclosure Table of Contents Important Safeguards Page 2 Exploded View Hardware 3 Assembl...

Page 2: ...any and all leaks are corrected If you are unable to stop a leak disconnect the LP gas supply Call a gas appliance serviceman or your local LP gas supplier Do not store or use gasoline or other flamm...

Page 3: ...141 13 Side Burner Grid 55 09 145 14 Side Burner 55 09 143 15 Left Side Shelf Front 55 09 131 16 Left Main Burner Control Knob Bezel 55 09 134 17 Right Main Burner Control Knob Bezel 55 09 135 18 Side...

Page 4: ...cable tighten all hardware connections by hand first Once the step is completed go back and fully tighten all hardware Follow all steps in order to properly assemble your product To complete assembly...

Page 5: ...to place of purchase For great recipes and tips visit recipes uniflame com page no 5 Attach Front Panel B x 4 6 Attach Rear Cart Frame Support and Cart Support Wire B B x 6 8 Attach LP Gas Tank Retai...

Page 6: ...ssembly Instructions continued 10 Attach Grill Body Assembly B x 4 F x 4 G x 4 11 Attach Side Burner Control Knob Bezel and Right Side Shelf Front A x 2 12 Attach Side Burner Assembly C x 2 9 Attach T...

Page 7: ...ase For great recipes and tips visit recipes uniflame com page no 13 Assemble Left Side Shelf C x 2 14 Attach Left Side Shelf B x 1 C x 4 15 Attach Right Side Shelf and Attach Ignitor Wire B x 1 C x 4...

Page 8: ...Outdoor LP Gas Barbecue Grill Model No GBC920W1 Assembly Instructions continued 18 Placement of Lighting Rod 19 Insert Heat Plate and Cooking Grid 20 Insert Warming Rack 17 Attach Control Knobs...

Page 9: ...e is facing the gas line connection Secure LP Gas Tank Secure tank by sliding tank retainer wire over shoulder of LP gas tank Connect LP Gas Tank Before connecting be sure that there is no debris caug...

Page 10: ...by turning the LP gas tank valve to CLOSED Burn off remaining gas in lines by waiting 15 seconds then turn all burner controls to the OFF position A poof sound is normal as the last of the LP gas is b...

Page 11: ...disconnected 2 DO NOT clean any grill part in a self cleaning oven The extreme heat will damage the finish Notices 1 This grill should be thoroughly cleaned and inspected on a regular basis 2 Abrasive...

Page 12: ...roper installation or improper maintenance or service by you or any third party or failure to perform normal and routine maintenance on the product as set out in this owner s manual In addition the Li...

Page 13: ...e still too low reset the excessive flow safety device by turning control knobs OFF and LP gas tank valve to CLOSED Disconnect regulator Turn control knobs to HIGH Wait 1 minute Turn control knobs to...

Page 14: ...Outdoor LP Gas Barbecue Grill Model No GBC920W1...

Page 15: ...Parrilla de gas propano para exteriores modelo no GBC920W1...

Page 16: ...ado Desconecte el regulador Gire las perillas de control a la posici n HIGH alto Espere 1 minuto Gire las perillas de control a la posici n OFF Apagado Vuelva a conectar el regulador y verifique las c...

Page 17: ...n o reemplazo de las piezas que resulten defectuosas en condiciones de servicio y uso normal y las que un examen indique a satisfacci n del fabricante que est n defectuosas Antes de devolver cualquie...

Page 18: ...lado del quemador vea Figura 8 Importante Use siempre la vara de encendido que se incluye cuando desee encender los quemadores con una cerilla 9 D espu s de encender el quemador observe su llama y ase...

Page 19: ...utos para dejar que la zona quede despejada de gas antes de volver a encenderlo Apagado 1 C ierre el gas girando la v lvula del tanque de propano a la posici n CLOSED Cerrado 2 G ire todas las perilla...

Page 20: ...ula del tanque quede orientada hacia la conex on de la l nea de gas Asegurar el tanque de propano Asegure el tanque pasando el alambre de retenci n del tanque por sobre el hombro del tanque de propano...

Page 21: ...riores modelo no GBC920W1 Instrucciones de armado continuaci n 18 Colocaci n de la vara de encendido 19 Coloque la placa de calentamiento y la parrilla de cocci n 20 Coloque la rejilla de calentamient...

Page 22: ...sugerencias visite recipes uniflame com p gina 13 Arme la repisa izquierda C x 2 14 Fije la repisa izquierda B x 1 C x 4 15 Fije la repisa derecha y conecte el cable del encendedor B x 1 C x 4 16 Fij...

Page 23: ...aci n 10 Fije la carcasa de la parrilla B x 4 F x 4 G x 4 11 Fije el soporte de la perilla de control del quemador lateral y el panel frontal de la repisa derecha A x 2 12 Fije el conjunto del quemado...

Page 24: ...ner excelentes recetas y sugerencias visite recipes uniflame com p gina 5 Fije el panel frontal B x 4 6 Fije el apoyo trasero del marco y la vara de soporte B del carro B x 6 7 Fije las varas de sopor...

Page 25: ...e a mano en un principio las conexiones de ferreter a Una vez que ha terminado el paso apriete completamente todos los elementos de ferreter a S iga todos los pasos en el orden indicado para armar deb...

Page 26: ...5 Panel frontal de la repisa izquierda 55 09 131 16 Soporte de la perilla del quemador principal izquierdo 55 09 134 17 Soporte de la perilla del quemador principal derecho 55 09 135 18 Soporte de la...

Page 27: ...a hasta que todas la fugas hayan sido reparadas Si no puede parar una fuga desconecte el tanque de propano Llame a un t cnico o a su proveedor de propano local N o guarde o use gasolina u otros l quid...

Page 28: ...onal de Gas Combustible ANSI Z223 1 NFPA 54 C digo de Instalaci n de Propano y Gas Natural CAN CGA B149 1 o el C digo de Manipulaci n y Almacenaje de Propano B149 2 Proposici n 65 de California La com...

Reviews: