background image

Natural Gas Conversion Kit for

GBC1059WE-C / Gilmour

GBC1069WB-C / Jackson

GBC1076WE-C / Memphis

Manufactured in China for: Blue Rhino Global Sourcing, Inc
Winston-Salem, NC USA • 1.800.762.1142, www.bluerhino.com

© 2010 Blue Rhino Global Sourcing, Inc. All Rights Reserved
UniFlame

®

 is a Registered Trademark of Blue Rhino Global Sourcing, Inc.. All Rights Reserved. 

 VFK1000W-C-OM-104 EF

WARNING

FOR YOUR SAFETY:

1.  Improper installation, adjustment, alteration, 

service or maintenance can cause injury or 
property damage.  

2.  Read the installation, operation and 

maintenance instructions thoroughly before 
installing or servicing this equipment.  

3.  Fuel system must be installed by a 

qualified and licensed personnel. Improper 
installations present hazards, which can 
lead to personal injury or property damage. 
Please contact your local Natural Gas 
supplier for these services.

4.  Failure to follow these instructions could 

result in fire or explosion, which could cause 
property damage, personal injury or death. 

WARNING

FOR YOUR SAFETY:

For Outdoor Use Only 

(outside any enclosure)

Table of Contents

Important Safeguards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 2
Exploded View & Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3
Conversion Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3
Installling Natural Gas Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11

Connect Natural Gas line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
Disconnect Natural Gas Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11

Operating Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11

Checking for Leaks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
Operating Main Burners  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
Operating Infrared Sear Burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
Operating Side Burner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
Operating Infrared Back Burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11

Cleaning and Care  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
Limited Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
The use and installation of this product must conform to local codes. In absence 
of local codes, use the 

National Fuel Gas Code, ANSI Z223.1/NFPA 54, Natural Gas 

and Propane Installation Code, CSA B149.1, 

or

 Propane Storage and Handling Code, 

B149.2.  

CONVERSION INSTRUCTIONS

Made from 70% Bagasse

(Environmentally Friendly Sugar

Cane Pulp By-product)

This Natural Gas Conversion Kit can be used ONLY 

with the grills listed above.

Save these instructions for future reference.   
If you are assembling this unit for someone else,  
give this manual to him or her to read and save  
for future reference.  

Installation should be done by a qualified service 

person.

Use only Blue Rhino Global Sourcing, Inc. factory authorized 
parts. The use of any other part that is not factory authorized 
can be dangerous and will void your warranty.

Summary of Contents for GBC1059WE-C / Gilmour

Page 1: ...utside any enclosure Table of Contents Important Safeguards Page 2 Exploded View Hardware 3 Conversion Instructions 3 Installling Natural Gas Line 11 Connect Natural Gas line 11 Disconnect Natural Gas...

Page 2: ...spect the hose before each use of the appliance If there is evidence of abrasion wear cuts or leaks the hose must be replaced prior to the appliance being put into operation Use only the regulator and...

Page 3: ...2 1142 toll free Please have your owner s manual and model number available for reference For Easiest Conversion To avoid losing any small components or hardware assemble your product on a hard level...

Page 4: ...76WE C Conversion Instructions 4 Remove Burners and Igniter Wires GBC1059WE C GBC1059WE C B x 4 GBC1069WB C GBC1069WB C A x 2 B x 3 GBC1076WE C GBC1076WE C A x 2 B x 4 3 Remove Lid s GBC1059WE C GBC10...

Page 5: ...turn to place of purchase page no 5 6 Remove Infrared Back Burner Covers GBC1059WE C GBC1076WE C GBC1069WB C GBC1059WE C GBC1076WE C A x 5 C x 5 E x 3 GBC1069WB C A x 5 C x 5 E x 3 5 Remove Main Burne...

Page 6: ...WE C GBC1069WB C GBC1076WE C Conversion Instructions continued 7 Remove the Infrared Back Burner Front Orifice GBC1059WE C GBC1069WB C GBC1076WE C 8 Remove Infrared Back Burner Rear Orifice GBC1059WE...

Page 7: ...e Burner Grid Igniter Wire and Side Burner GBC1059WE C GBC1076WE C GBC1059WE C GBC1076WE C A x 2 11 Remove Side Burner Orifice GBC1059WE C GBC1076WE C 9 Attach Infrared Back Burner Covers GBC1059WE C...

Page 8: ...WB C GBC1076WE C Conversion Instructions continued 12 Remove LP Gas Regulator Hose Assembly and Attach Natural Gas Hose Assembly GBC1059WE C GBC1076WE C GBC1069WB C 13 Attach Side Burner Igniter Wire...

Page 9: ...ase page no 9 15 Attach Lid s GBC1059WE C GBC1076WE C GBC1069WB C GBC1059WE C GBC1076WE C F x 2 H x 2 GBC1069WB C F x 2 G x 1 H x 3 14 Attach Burners and Igniter Wires GBC1059WE C GBC1059WE C B x 4 GB...

Page 10: ...is present Gas leaks may cause a fire or explosion 2 You must follow all leak checking procedures before operating To prevent fire or explosion hazard when testing for a leak a Always perform leak tes...

Page 11: ...e original retail purchaser of this product and to no other person that if this product is assembled and operated in accordance with the printed instructions accompanying it then for a period of one 1...

Page 12: ...Natural Gas Conversion Instructions VKF1000W C Model No GBC1059WE C GBC1069WB C GBC1076WE C...

Page 13: ...uincaillerie 3 Instructions d assemblage 3 Installer la bouteille de propane 11 Brancher le tuyau de gaz 11 D brancher le tuyau de gaz 11 Fonctionnement 11 Rechercher une fuite potentielle 11 Fonction...

Page 14: ...onnement Utiliser uniquement le r gulateur et le tuyau fournis Le r gulateur et le tuyau de rechange doivent tre ceux sp cifi s par le fabricant Utiliser uniquement des pi ces agr es de l usine Blue R...

Page 15: ...n afin de pouvoir vous y r f rer Remarque Le mod le num ro se trouve au dos du chariot Pour faciliter la conversion Pour viter de perdre des petites pi ces ou la quincaillerie d installation assemblez...

Page 16: ...ions de conversion suite 3 Retirer les couvercles GBC1059WE C GBC1076WE C GBC1069WB C GBC1059WE C GBC1076WE C F x 2 H x 2 GBC1069WB C F x 2 G x 1 H x 3 4 Retirer les br leurs et les fils de l allumeur...

Page 17: ...de vente page 5 6 Retirer les proctecteurs du br leur arri re infrarouge GBC1059WE C GBC1076WE C GBC1069WB C GBC1059WE C GBC1076WE C A x 5 C x 5 E x 3 GBC1069WB C A x 5 C x 5 E x 3 5 Retirer les pi ce...

Page 18: ...WE C Instructions de conversion suite 8 Retirer la pi ce de l orifice arri re du br leur arri re infrarouge GBC1059WE C GBC1069WB C GBC1076WE C 7 Retirer la pi ce de l orifice avant du br leur arri re...

Page 19: ...fil de l allumeur et le br leur lat ral GBC1059WE C GBC1076WE C GBC1059WE C GBC1076WE C A x 2 11 Retirer la pi ce de l orifice du br leur lat ral GBC1059WE C GBC1076WE C 9 Fixer les proctecteurs du br...

Page 20: ...tions de conversion suite 12 Retirer le r gulateur de propane et son tuyau et fixer le tuyau souple d alimentation en gaz naturel GBC1059WE C GBC1076WE C GBC1069WB C 13 Fixer le br leur lat ral le fil...

Page 21: ...page 9 15 Fixer les couvercle s GBC1059WE C GBC1076WE C GBC1069WB C GBC1059WE C GBC1076WE C F x 2 H x 2 GBC1069WB C F x 2 G x 1 H x 3 14 Fixer les br leurs et les fils de l allumeur GBC1059WE C GBC105...

Page 22: ...e d tection de fuite avant d utiliser le barbecue Pour viter tout risque d incendie et d explosion lorsque vous recherchez une fuite a Veiller toujours effectuer une d tection de fuite avant d allumer...

Page 23: ...au 1 800 762 1142 ou consultez notre site www bluerhino com Fonctionnement du br leur arri re infrarouge Consultez le manuel d utilisation de votre barbecue Si vous ne poss dez pas le manuel d utilis...

Page 24: ...Trousse de conversion au gaz naturel VKF1000W C mod les n GBC1059WE C GBC1069WB C GBC1076WE C...