Uniflame GAD1200B Owner'S Manual Download Page 2

LP Gas Outdoor Fireplace Model No. GAD1200B

  This appliance is for outdoor use only, and shall NOT be used in a 

building, garage or any other enclosed area.

  Do NOT operate, light or use this appliance within ten (10) feet (3.05 m) 

of walls, structures or buildings.

  For residential use only. This outdoor fireplace is NOT for commercial use.
  This outdoor fireplace is safety certified for use in the United States and/

or Canada only. Do not modify for use in any other location. Modification 
will result in a safety hazard.

  Do NOT use this outdoor fireplace for indoor heating. TOXIC carbon 

monoxide fumes can accumulate and cause asphyxiation. 

  Apartment Dwellers: Check with management to learn the requirements 

and fire codes for using an LP gas outdoor fireplace in your apartment 
complex. If allowed, use outside on the ground floor with a ten (10) foot 
(3.05 m) clearance from any structure. Do not use on or under balconies.

  This outdoor fireplace is for use with liquid propane (LP) gas only. The 

conversion to or attempted use of natural gas in this outdoor fireplace is 
dangerous and will void your warranty.

   LP gas is flammable and hazardous if handled improperly.  Become 

aware of the characteristics before using any LP gas product.  

  a.  LP gas is explosive under pressure, heavier than air, and settles and 

pools in low areas. 

  b.  LP gas in its natural state has no odor.  For your safety, an odorant is 

added that smells like rotten cabbage.  

  c. Contact with LP gas can cause freeze burns to skin.

   LP gas tank needed to operate. Only tanks marked “propane” may be 

used.  

a.  The LP gas supply tank must be constructed and marked in 

accordance with the 

Specifications for LP gas LP gas tanks of the 

U.S. Department of Transportation (DOT) or the National Standard 
of Canada, CAN/CSA-B339, LP gas tanks, Spheres and Tubes for the 
Transportation of Dangerous Goods; and Commission.  

b. LP gas tank must be arranged for vapor withdrawal.
c.  The LP gas tank must have a listed overfilling prevention device (OPD) 

and a QCCI or Type I (CGA810) LP gas tank connection.

d. The LP gas tank must have a tank collar to protect the tank valve.
e.  Never use an LP gas tank with a damaged body, valve, collar or footing.  
f.  Dented or rusted LP gas tanks may be hazardous and should be 

checked by your LP gas supplier prior to use.

g.  The LP gas tank should not be dropped or handled roughly. 
h.  Tanks must be stored outdoors, out of the reach of children and must 

not be stored in a building, garage or any other enclosed area. Your 
LP gas tank must never be stored where temperatures can reach over 
125°F. 

  i.  Do not insert any tool or foreign object into the valve outlet or safety 

relief valve. You may damage the valve and cause a leak. Leaking 
propane may result in explosion, fire, severe personal injury or death.

j.  Never keep a filled LP gas tank in a hot car or car trunk. Heat will cause 

the gas pressure to increase, which may open the relief valve and allow 
gas to escape.

k.  Place dust cap on valve outlet whenever the LP gas tank is not in use. 

Only install the type of dust cap on the LP gas tank valve outlet that is 
provided with the LP gas tank valve. Other types of caps or plugs may 
result in leakage of propane.

l. Do not store a spare LP gas tank under or near this appliance.
m.  Never fill the tank beyond 80 percent full.

  Your outdoor fireplace has been checked at all factory connections 

for leaks.  Recheck all connections as described in the “Operating 
Instructions” section of this manual, as movement in shipping can loosen 
connections.  

  Check for leaks even if your unit was assembled for you by someone 

else.

  Do not operate if gas leak is present. Gas leaks may cause a fire or 

explosion.

  You must follow all leak-checking procedures before operating. To 

prevent fire or explosion hazard when testing for a leak:

a.  Always perform leak test before lighting the outdoor fireplace and 

each time the tank is connected for use.

b.  No smoking.  Do not use or permit sources of ignition in the area while 

conducting a leak test. 

c.  Conduct the leak test outdoors in a well-ventilated area.  
d.  Do not use matches, lighters or a flame to check for leaks.  
e.  Do not use outdoor fireplace until any and all leaks are corrected.   

If you are unable to stop a leak, disconnect the LP gas supply.  Call a 
gas appliance serviceman or your local LP gas supplier.

  Do not store or use gasoline or other flammable liquids or vapors within 

25 feet (7.62 m) of this appliance.

  Do not use in an explosive atmosphere. Keep outdoor fireplace area 

clear and free from combustible materials, gasoline and other flammable 
vapors and liquids.  

  This outdoor fireplace is NOT to be operated by children.
  This outdoor fireplace is NOT to be used in or on boats or recreational 

vehicles.

  Do NOT connect to a remote gas supply.
  Never attempt to attach this outdoor fireplace to the self-contained LP 

gas system of a camper trailer, motor home or house.  

  Always use in accordance with all applicable local, state and national 

codes. Contact your local fire department for details on outdoor burning.

  When using this outdoor fireplace, exercise the same precautions you 

would with any open fire.

  The use of alcohol, prescription or non-prescription drugs may impair 

the consumer’s ability to properly assemble or safely operate this 
outdoor fireplace.

  Do NOT use this outdoor fireplace without reading the entire “Owner’s 

Manual”. 

  Do NOT burn solid fuels such as: wood, charcoal briquets, lump charcoal, 

manufactured logs, driftwood, trash, leaves, paper, cardboard, plywood, 
painted or stained or pressure treated wood in this outdoor fireplace.

  It is essential to keep the outdoor fireplace’s valve compartment, 

burners, and circulating air passages clean.  Inspect outdoor fireplace 
before each use.

  Do NOT use this outdoor fireplace until it is COMPLETELY assembled and 

all parts are securely fastened and tightened.

  Do NOT use this outdoor fireplace near automobiles, trucks, vans or 

recreational vehicles. 

  Do NOT use this outdoor fireplace under any overhead or near any 

unprotected combustible constructions. Avoid using near or under 
overhanging trees and shrubs.

  Always use this outdoor fireplace on a hard, level, non-combustible 

surface such a concrete, rock or stone. An asphalt or blacktop surface 
may not be acceptable for this purpose. 

  Do NOT use this outdoor fireplace for cooking.
  Do NOT use this outdoor fireplace if any part has been under water. 

Immediately call a qualified service technician to inspect the appliance 
and to replace any part or control system and any gas control which has 
been under water.

  Do NOT wear flammable or loose clothing when operating this outdoor 

fireplace.

  Do NOT use in windy conditions.
  Never lean over this outdoor fireplace when lighting or when in use.
  Do NOT use this outdoor fireplace unless burner is securely in place.
  Keep all electrical cords away from outdoor fireplace during use.
  Certain areas of this outdoor fireplace when in use will become too 

hot to touch. To avoid burns, do not touch hot surfaces until the unit 
has cooled (about 45 minutes) unless you are wearing protective gear 
(insulated pot holder or heat resistant gloves or mittens).

 DANGER:  Failure to follow the dangers, warning and cautions in this manual may result in serious bodily injury or death, or in a fire or an explosion 

causing damage to property.

 WARNING: 

DANGERS and WARNINGS:  FOR YOUR SAFETY

Summary of Contents for GAD1200B

Page 1: ...CLOSURE Do Not Use For Cooking WARNING FOR YOUR SAFETY If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life...

Page 2: ...someone else Do not operate if gas leak is present Gas leaks may cause a fire or explosion You must follow all leak checking procedures before operating To prevent fire or explosion hazard when testin...

Page 3: ...sembly provided The replacement regulator and hose assembly shall be that specified by the manufacturer Use only Blue Rhino Global Sourcing Inc factory authorized parts The use of any part that is NOT...

Page 4: ...EFT OOR 20 OOR 3UPPORT EG 21 2IGHT OOR 22 Right Front Leg 23 OOR NOB 24 ASE 25 0 AS 4ANK 4RAY 26 OOT 27 OVER NOT SHOWN 0RE ASSEMBLED Exploded View Tools Required for Assembly Included LLEN 7RENCH PC T...

Page 5: ...RDWARE s 7HEN APPLICABLE TIGHTEN ALL HARDWARE CONNECTIONS BY HAND FIRST NCE THE STEP IS COMPLETED GO BACK AND FULLY TIGHTEN ALL HARDWARE s OLLOW ALL STEPS IN ORDER TO PROPERLY ASSEMBLE YOUR PRODUCT 4O...

Page 6: ...ach Side Panels Right Front Leg and Middle Support Leg A x 12 B x 2 5 Attach Side Panels Left Front Leg and Middle Support Leg A x 12 B x 2 8 Attach Door Support Leg and Feet A x 4 B x 2 7 Attach Base...

Page 7: ...lace of purchase PAGE NO 7 11 Attach Doors C x 2 10 Attach Base Support Bar A x 2 9 Attach Tank Guard x 3 12 Place Wood Grid and Lava Rocks O 4 DUMP LAVA ROCKS OUT OF PACKAGE AREFULLY PLACE LAVA ROCKS...

Page 8: ...by turning valve clockwise 0LACE PRECISION FILLED 0 GAS TANK UPRIGHT INTO HOLE IN THE BASE OF THE OUTDOOR FIREPLACE SO IT IS ARRANGED FOR VAPOR WITHDRAWAL Secure LP Gas Tank 4URN WING NUT CLOCKWISE U...

Page 9: ...THIS UNIT 3TORE IN A COOL AND DRY LOCATION AWAY FROM CHILDREN AND PETS Checking for Leaks WARNING Before using this outdoor fireplace make sure you have read understand and are following all informati...

Page 10: ...TIES DUE TO ACCIDENT ABUSE MISUSE ALTERATION MISAPPLICATION IMPROPER INSTALLATION OR IMPROPER MAINTENANCE OR SERVICE BY YOU OR ANY THIRD PARTY OR FAILURE TO PERFORM NORMAL AND ROUTINE MAINTENANCE ON T...

Page 11: ...RI AND BURNER TUBE URNER PORTS CLOGGED OR BLOCKED LEAN BURNER PORTS Sudden drop in gas flow or reduced flame height UT OF GAS 2EPLACE OR REFILL 0 GAS TANK XCESS FLOW SAFETY DEVICE MAY HAVE BEEN ACTIVA...

Page 12: ...LP Gas Outdoor Fireplace Model No GAD1200B...

Reviews: