FLOW ADJUSTMENT of INTEG 80
The flow is set by adjusting the opening slot ”B”. (outlet area)
This is done by rotating the baffle ”A” that rides on a threaded rod, M16 x 2.
1. Rotate the baffle ”A” clockwise until it stops. Now the slot ”B” is closed. (pos=0)
2. Open by rotating counter-clockwise
. 360° =
1
"Turn"
.
3. Lock baffle in position with the M16 counter-nut ”C”
.
U
se locktite 243 or 577 on the nut.
For example: 720° (2 Turns) leaves slot
”B” open by
4,0
mm wich equals a flow of
3
000 lit/min at
10
Bar inlet pressure