6
LEF-Series | Version 1.02
Technical Data
4 Technical Data
4.1 Type plate
Fig. 2: Type plate LEF 50 S
4.2 Installation conditions
Set up dehumidifier
Operate the dehumidifier in a closed area as it creates a
drying chamber. Close any doors, windows or areas
that open to the outside to maximize the dehumidifier's
water removal efficiency. Place the dehumidifier in the
middle of the room, away from walls, heat sources and
furnishings. Prevent the airflow from being obstructed.
Fig. 3: Dimensions for installation conditions
4.3 Principle of operation
The dehumidifier works on the condensation principle.
The room air is sucked through a filter and through a
cooling element, where the water vapors of the air
condense to water droplets. The drops of water then run
into a condensed water tray and further into the water
tank, while the dried cold air is passed through the
condenser of the unit and heated again blown into the
room. The temperature of the blown air is approx. 2-5 °
C above room temperature. This heat gain is generated
by the energy supplied to the compressor and fan, as
well as the heat that is released when condensing the
water vapor.
Due to the constant circulation of the room air through
the device, the relative humidity of the air is gradually
reduced, whereby a quick and gentle drying of the room
is achieved.
LEF 50 S
LEF 70 S
LEF 90 S
Length
550 mm
555 mm
555 mm
Width / Depth
500 mm
480 mm
480 mm
Height
700 mm
820 mm
820 mm
Weight
36 kg
38,5 kg
41 kg
Input
550 W
750 W
960 W
Output
455 W
712 W
850 W
Speed
1200 min¯¹
1350 min¯¹
1350 min¯¹
Efficiency
83 %
95 %
88 %
Protection
class
IP 20
IP 20
IP 20
Current con-
sumption
2.3 A
3.6 A
4.3 A
Voltage
230 V
230 V
230 V
Cable length
4.5 m
4.5 m
4.5 m
Air flow
600 m³/h
700 m³/h
850 m³/h
Ø Aspiration
150 mm
150 mm
150 mm
Air outlet
speed
9.6 m/s
11.8 m/s
12.6 m/s
Ø Rotor
170 mm
170 mm
170 mm
Outlet Size
[mm]
303x285
317x280
317x280
Dehumidifica-
tion Power
(30°C / 80%
RH)
50 l/24std
70 l/24std
90 l/24std
Sound pres-
sure level
42 db(A)
45 db(A)
48 db(A)
Coolantl
R410a
R410a
R410a
Temperature
1 - 36°C
1 - 36°C
1 - 36°C
ATTENTION!
Always place the humidifier in an upright position. If
you are transporting a dehumidifier to the site, let it
stand for 30 minutes before turning it on. This is nec-
essary to stabilize the cooling system and avoid sys-