17
Figure 5-1 LED Indicators
6
Configuration Commands
UB482 supports abbreviated ASCII format. All commands are composed of a log
heading and configuration parameters.
Common instructions are shown in the following table:
Table 6-1 Common Instructions
Command
Description
freset
Reset to factory settings.
Note
: the factory set baud rate is 115200 bps.
version
Query the hardware version, firmware version of receivers
config
Current configuration of each port of the receiver
mask BDS
Mask (disable) tracking of Beidou satellite system. BDS, GPS, GLONASS and
Galileo can be disabled separately
unmask BDS
Unmask (enable) tracking of Beidou satellite system. BDS, GPS, GLONASS
and Galileo can be enabled separately.
By default, all satellite systems are tacked.
config com1
115200
Set the baud rate of com1 to 115200. Baud rates of com1, com2 and com3
can be set to any of the following: 9600, 19200, 38400, 57600, 115200,
230400,460800
unlog
Disable all output to the current port
saveconfig
Save configuration to NVM (nonvolatile memory)
mode base
time 60 1.5 2.5
Derive an average coordinate after 60 seconds
—
a “better than
1.5 meter
horizontal and less than 2.5-meter
height accuracy”
is achieved within 60
seconds.