6.

 Controls and indicators 

The content of controls and indicators depends on the device configuration: 

-

 

for configuration of the devices of base and with remote control, a basic set of 

controls and indicators is used (see para. 6.1); 

-

 

for configuration of the device with integrated control, an extended content of the 

controls and indicators is used (see para. 6.2). 

6.1

 

Basic Set of Controls and Indicators 

The basic device configuration includes the following controls and indicators: four 

LEDs indicating PS state and operation mode (see Figure 5) and an audio alarm 
acknowledgement button. 

1. LEDs “AC Present”, “DC Output”, “Charging”, “ALARM” – are designed to 

indicate current operation mode (see Figure 5, Table 3).  

2. Button “Mute” is designed to switch off audio alarm, and light alarm will be 

activated until the cause of alarm actuation is eliminated. 

AC Present

DC Output

Charging

ALARM 

Mute

Power / Charger Unit

 

Figure 5. Location of Controls and Indicators 

Table 3. Purpose of LED Indicators 

LED Indicator 

Purpose 

AC Present (green) 

Flashes, where there is input supply 220 V 

DC Output (green) 

Flashes, where there is output supply 24 V 

Charging (green) 

Flashes while charging SB. 

ALARM (red) 

Flashes in case of abnormal operation mode of the device (abnormal 
operation modes, Table 8). 

Summary of Contents for PCH-205

Page 1: ...Unicont SPb Ltd Power Supply Automatic Battery Charger PCH 205 Technical Documentation 205 1 27062012 St Petersburg 2012...

Page 2: ...3 SPECIFICATIONS 6 4 SAFETY ENGINEERING INSTRUCTIONS 7 5 OPERATION PRINCIPLE 8 6 CONTROLS AND INDICATORS 9 7 INSTALLATION AND CONNECTION 14 8 ALARM SIGNALS OF PCH 205 19 9 TRANSPORTATION AND STORAGE 2...

Page 3: ...aintenance This Manual can also be used as a source of information about to draw up corresponding sections in the operational documentation for the equipment this product may be used as its component...

Page 4: ...H 205 1 ps 2 Operator s manual 1 ps The following devices can be used additionally optionally with this product 1 Control panel of storage batteries BCP 136 2 Alarm unit AU 106 3 Temperature sensor of...

Page 5: ...Unicont SPb Ltd Technical Documentation PCH 205 Page 5 Figure 1 Base Configuration PCH 205 Figure 2 Configuration PCH 205 with Integrated Control Figure 3 Configuration PCH 205 with Remote Control...

Page 6: ...ly from the supply main connection of SB with reverse polarity protection of the battery against deep discharge a deactivated function overheat protection of PS CHD overheat protection of SB when usin...

Page 7: ...engineering Instructions IMPORTANT Do not allow contact of the device with water and water penetration into the device IMPORTANT When cleaning the device surface do not use organic solvents to avoid...

Page 8: ...the SB When restoring supply voltage the switching unit automatically switches the load to supply from the power supply unit and charge of SB is resumed in automatic mode Thus the device allows automa...

Page 9: ...PS state and operation mode see Figure 5 and an audio alarm acknowledgement button 1 LEDs AC Present DC Output Charging ALARM are designed to indicate current operation mode see Figure 5 Table 3 2 But...

Page 10: ...ose of the Buttons Table 4 Table 4 Purpose of Control Buttons Button Purpose SELECT Main menu option select button and Parameter value select button SET Mute Confirmation preservation button of the se...

Page 11: ...the diagram of voltage and charging current curves Figure 4 Failure red Flashes in case of SB discharging or abnormal operation mode of the device see Alarm Table Table 5 6 2 1 Structure of PS Configu...

Page 12: ...played on the right device indicator with buttons and set the required value of charging voltage press button SET to confirm the set value and its record into nonvolatile memory of the device 6 2 3 Ch...

Page 13: ...attery Note By default the PS is shipped set for connection with SB with operating voltage 24 V and has the following preset settings U 28 4 V I 20 A 6 3 Function of Battery Deep Discharge Protection...

Page 14: ...commended to be mounted on the vertical bulkhead IMPORTANT The PS shall be installed at a safe distance from a light port to prevent water penetration into the device when opening the light port IMPOR...

Page 15: ...2 2 2 0 5 11 J9 Connection of a temperature sensor TS 2 2 0 5 12 J14 Connection of storage battery control unit Remote Bat_control 2 0 5 J8 2 2 0 5 4 Remove the device lid 5 Pass connecting wires of t...

Page 16: ...Control by delivering with the digital indicators SB current and voltage values 12 Close the PS lid The following settings refer only to the device configuration with integrated control 13 In 5 secon...

Page 17: ...106 see Figure 9 The control panel of storage batteries BCP 136 is designed for remote control of any PS configurations see para 7 1 2 Connection is carried out with a standard interface RS 422 The c...

Page 18: ...evice is required Except for the main function of current value indication and device control BCP 136 backups audio and light alarm in alarm situations see para 8 Figure 11 External view BCP 136 When...

Page 19: ...hen switching on the PS Flashes Signal Open Connection of SB to the PS with reverse polarity actuates only when the PS is switched on Flashes Signal Open Overvoltage in the PS power circuit Flashes Si...

Page 20: ...port automobile and railway closed transport covered wagons universal containers by air in pressurized and heated bays of airplane by sea in dry service spaces The device shall be transported in accor...

Page 21: ...s You can also send the overage equipment to the manufacturer for its further recycling Proper recycling of the product components will prevent potential negative consequences for human health and the...

Page 22: ...condition or has a damaged body and other causes beyond the manufacturer s control 4 If self made electrical devices were used 5 If there was an attempt to repair the unit by a person who is not an au...

Page 23: ...rial number was manufactured and accepted in accordance with the regulatory requirements of the state standards and applicable technical documentation and is suitable for operation Quality control rep...

Reviews: