6
Revised 15/12/21
01865 767676
www.unicol.com
AVMW – STEP 1
The rear of the unit is inaccessible once wall fitted
so it is important to cable up first. (Do not fit screen).
When using a PZX1 or PZX3 for 33-70” screens,
remove rear covers and follow AVMT Steps 2, 3 & 4.
When using a PZX9 for 71 - 100” screens, remove
rear covers and follow AVMT Steps 2 & 4, but
replace AVMT Step 3 with the above.
AVMW – STEP 2
Using the 4 x M10 x 25 hex head screws loosely
fix one of the wall brackets to the top plate and the
other wall bracket to the bottom plate.
There is a small amount of adjustment in the slots,
which can be used when levelling unit to wall.
AVMW – STEP 3
Decide the height on the wall where the bottom of
the unit should be. Mark and drill. Use appropriate
anchors and fix the bottom wall bracket.
NOTE:
The wall has to be capable of supporting 5
times the load of the combined display and unit.
Therefore, it may be necessary to reinforce the floor
and wall before starting this installation.
AVMW – WALL FIXED
Additional
converter
plate
AVMW – STEP 4
With the help of another person place the PowaLift
Module into the sockets. Whilst supporting the unit
mark the wall for the top wall bracket fixing holes
ensuring the unit is level. Lift unit out from floor
plate, drill and fit suitable anchors. Refit unit to
base and fix wall plate to wall (fixings not supplied).
Tighten all screws in top and base.
Follow Steps 5,7 & 8 of AVMT instructions to
complete installation.