3.8.2 - RECIRCULATION PUMP
For correct generator operation, a recirculation pump must
be installed in the boiler.
The recirculation pump, supplied in an optional kit, must be
connected is indicated in the figure.
The recirculation pump must assure a return temperature
equal to or greater than 55°C.
It must be controlled exclusively from the boiler control
panel.
If it is not installed, besides limiting the boiler's lifespan, it
will invalidate the warranty.
ATTENTION!
The hardness of the mains water supply con-
ditions the boiler's lifespan.
It is always recommended to treat water with a
hardness greater than 15°f.
Unical has designed a "RECIRCULATION KIT FOR OPERATION
WITH STORAGE TANK" for its customers.
The kit is supplied as an option and is available by indicating
the model of your boiler.
3.8.3 - ASSEMBLY INSTRUCTIONS
Fan assembly
Fit the fan to the smoke chamber.
IMPORTANT!
When the fan is being installed
the smoke chamber gasket must be
perfectly sealed, otherwise the wall of the
gasket would deform, causing serious
damage to the impeller and/or fan motor.
This issue occurs even more quickly the more
the wood loading door is opened.