5
L - Burner in operation signal
This symbol indicates that the burn
-
er is in operation / it also indicates
the burner modulation via the flame
level.
The symbol lights up when the boil
-
er receives a request for heating or
domestic hot water production.
F - Operation in heating mode
The symbol lights up when the
boiler receives a request in heating
mode. If a request for domestic hot
water production is received at the
same time, the light switches off.
G - Operation in hot water
production mode
This symbol lights up when there
is a request for domestic hot water.
I - Block signal
The symbol lights up when the
burner safety device has inter
-
vened, due to:
- No gas
- Failed ignition
In the first case, in which the burner
will not light, one must check if the
gas valve is open.
M - Fault signal
The symbol lights up on the display
monitor when the boiler detects an
operation anomaly or it is blocked
due to a permanent fault. The code
that identifies the cause is displayed
in place of the degrees centigrade
by pressing the unblock button (D).
D - Unblock button
By acting on this button one can:
- restart the boiler after the burner
safety device has intervened, ac
-
tivating the symbol on the display
- display the error code when the
boiler operation is block due to
a permanent fault, activating the
symbol on the display
Thermometer
If, on the display, the symbol
(
) is lit up, the temperature in
-
dicated is that relating to the water
for the heating circuit
If, on the display, the symbol
(
) is lit up, the temperature in
-
dicated is that relating to the water
for the domestic hot water circuit.
A - Pressure gauge
Displays the water pressure inside
the heating circuit; this pressure
value must not be below 0.8/1 bar
(when cold).
If the pressure drops below 0.8/1
bar, one must restore the correct
value by acting on the system fill
-
ing valve. This operation must be
carried out when the boiler is cold.
ENGLISH
6.2 - CHECKS BEFORE COMMISSIONING
1 Make sure the gas shut-off valve upstream of
the boiler is open.
2
Check that any shut-off valves for mainte
-
nance, on the flow and return are open.
3
Check that the shut-off valve, for maintenance,
on the domestic cold water inlet is open.
4
Check that the safety valves outlet has been
connected to the drains.
5
Check that the boiler is powered electrically; the
display
(E)
on the control panel must be lit up.
6 Check the water pressure on the boiler pres
-
sure gauge
(A)
; for optimum operation, the
pressure should be between 0.8 and 1 bar
(with pump stopped).
Should the pressure be lower than 0.7 bar with
the system cold, restore pressure by opening
the system filling tap (see par. 6.4).
Summary of Contents for KON
Page 14: ...2 1 2 KON Unical AG S p A 4 3 15 f 2...
Page 15: ...3 P O K K C K O 5 Unical AG S p A...
Page 17: ...5 P O K K C K O L F G I M D D A 0 8 1 0 8 1 6 2 1 2 3 4 5 E 6 A 0 8 1 0 7 6 4...
Page 19: ...7 P O K K C K O 6 4 service D D 4 6 0 8 1 0 6 Unical 3 Unical Unical Unical AG S p A 2002 96...
Page 38: ......
Page 39: ......