background image

10

Operation  of  the  appliance  must  be  verified 

with an ignition test in compliance with the 

manufacturer installation instructions.

In any case, the functionality of the following 

parts must be checked:

- connection to flue gas exhaust system;

- external vents;

- electric and hydraulic connections.

• Before lighting the stove, carefully read the 

use and maintenance manual.

• Remove all equipment inserted in the tank 

when packaged and make sure it is clear of 

any foreign bodies.

• Check that the crucible is well inserted in its 

seat.

• Unroll the room temperature probe placed 

at the back of the stove, moving it to 

approximately 20 cm from any hot parts.

• Close the combustion chamber door. Never 

open the door when the pellet stove is 

operating.

• Connect the stove to a socket using the 

supplied cable.

Stove ignition

• Before lighting the stove, make sure that 

the brazier is clear of pellets and clean from 

residues of previous combustion. Otherwise 

empty and clean it.

•  Fill the tank up to 3/4 with good quality pellets, 

compliant with that described in the standard 

UNI EN 14961-2;

• Press the ignition switch at the back of the 

stove; the display will read “OFF”;

Ignition

• Press the key 

 for 2 seconds. After a few 

seconds, the flue gas extractor fan and the 

ignition resistance switch on and the text 

“FAN ACC” appears; the igniter LED lights 

up. 

-  After about 1 minute, the text “LOAD WOOD” 

appears, the stove loads the pellets and 

continues lighting the resistance;

-  When the proper temperature is reached, the 

display will read “FIRE ON”: this means that 

the stove has passed to the last ignition phase 

at the end of which it will be fully operational; 

the igniter LED switches off.

- After a few minutes, the display will read 

“ON1-2-3-4-5” according to the set output, 

alternated with the room temperature.

- When the set temperature is reached, the 

display will read: “ECO”, alternated with the 

room temperature.

- The temperature LED switches on when the 

set temperature is reached.

Stove extinction

To switch off the stove, press the key 

 on 

the control panel until the display reads “OFF”.

Even after extinction of the stove, the flue gas 

extractor fan will continue running for a preset 

amount of time to guarantee quick exhaust of 

the flue gas from the combustion chamber.

Summary of Contents for .it 10.5

Page 1: ...it INSTALLATION AND MAINTENANCE INSTRUCTIONS 7 8 5 10 5...

Page 2: ...ntre Continuing to use the appliance in these conditions can cause fires or electrocutions If the supplementary air vent is not used only for ducted models check that the fan speed is at zero deactiva...

Page 3: ...intenance Failure to comply with the instructions in the manuals Use which does not comply with safety directives Installation which does not comply with standards in force in the country Installation...

Page 4: ...f the roof or in contact with the outside for example for open lofts must be covered with bricks and in any case well insulated Be built in such a way so that rain snow or foreign objects do not enter...

Page 5: ...guarantee regular combustion and proper environmental well being Make sure that the room where the stove is installed is sufficiently aerated The outdoor air inlet must communicate with the stove and...

Page 6: ...exhaust pipe Pellet tank capacity Autonomy Rated electric absorption at ignition Weight Dimensions LxWxH it 7 kW kW kg h mm Litres kg h W kg mm 6 97 2 84 6 42 2 64 1 4 0 6 92 70 92 06 80 20 13 22 9 1...

Page 7: ...connected to an earthed socket if the supplied cable is not long enough to reach the closest socket use a suitable extension cord Safety distances for fire protection The stove must be installed whil...

Page 8: ...d outside is 4 Pa Fig 9 distances from walls Instructions to install the flame protection Fig 12 lifting the flame protection Fig 13 flame protection rotation Fig 14 removing the flame protection Fig...

Page 9: ...riods of time the tank must be emptied from any residual fuel Parameter Diameter D Length L Water content M Ashes A 32 Mechanical durability DU Fine particles 3 15 mm Additives Lower Calorific Value Q...

Page 10: ...with that described in the standard UNI EN 14961 2 Press the ignition switch at the back of the stove the display will read OFF Ignition Press the key for 2 seconds After a few seconds the flue gas ex...

Page 11: ...ified by the technician the flue gas is modulated as follows flue gas exhaust motor set at maximum speed pellet loading gearmotor at minimum speed tangential heat exchange fan at maximum speed This pr...

Page 12: ...s It reserves the right to modify its products as deemed necessary or useful without jeopardising their essential features 46033 casteldario mantova Italy tel 39 0376 57001 telefax 39 0376 660556 info...