1 = GREY PHASE
2 = BROWN PHASE
3 = BLACK PHASE
IN ALL CASES THE GREEN/YELLOW WIRE MUST BE CONNECTED TO THE EARTH OF THE
INSTALLATION
►
Electrical connection
- None of the switches on the machine must be left on.
- Check that the values of the voltage, frequency and power shown on the technical information plate of the
appliance match those of the mains.
♦
Electrical connections
IMPORTANT: The machine must be connected to a line fitted with a general cut-off.
The machine is delivered with a cable of 5 numbered wires.
Set the general cut-off to 0 before the intervention.
Check that the wiring of the machine matches the available mains voltage, in accordance with the connection
diagrams below. If necessary, modify by working on the jumpers on the terminal block located on the left-hand
side of the machine.
IMPORTANT:
Connection to 230 V with 5-strand cable, it is necessary to couple the wires at the end of the cable correctly.
Single-phase 230V connection: blue and black wires together, brown and grey wires together. Watch the
amperage (32 A)
Connection in 230V 3-phase: brown and grey wires together. Important: there is no neutral so the blue wire
must be connected to a phase
♦