Unic STELLA EPIC 3 User Manual Download Page 13

13

Customer

the person who purchased the machine
and/or who manages and uses it (e. g.
company, entrepreneur, firm).

Electrocution

an accidental discharge of electric current
on a human body.

C.3

Machine and manufacturer's
identification data

An example of the marking or data plate on the machine is
given below:

The data plate gives the product identification and technical
data. The meaning of the various information given on it is
listed below:

STELLA EPIC

commercial description

serial number

Volts (V)

power supply voltage (monophase
and/or triphase)

Hz

power supply frequency

Amp (A)

electrical intensity

W

max power input

Steam pressure
(MPa)

boiler pressure

Temperature (

)

boiler temperature

Water pressure (MPa)

water network pressure

Water pressure max
(MPa)

max water network pressure

CE

CE marking

UNIC, Z.I. 4ème rue -
B.P. 425, 06515
CARROS Cedex
France

manufacturer

The data plate is located on the front of the equipment.

IMPORTANT

When installing the machine, make sure the
electrical connection is carried out in compliance
with that specified on the data plate.

NOTE!
Refer to the data given on the machine's data plate
for relations with the Manufacturer (e.g. when
ordering spare parts, etc.).

C.4

Additional indications

The drawings and diagrams given in the manual are not in
scale. They supplement the written information with an outline,
but are not intended to be a detailed representation of the
machine supplied.
The numerical values given on the appliance installation
diagrams refer to measurements in millimeters and/or inches.

C.5

Responsibility

The Manufacturer declines any liability for damage and
malfunctioning caused by:

• non-compliance with the instructions contained in this

manual;

• repairs not carried out in a workmanlike fashion, and

replacements with parts different from those specified in
the spare parts catalogue (the fitting and use of non-original
spare parts and accessories can negatively affect machine
operation

and

invalidates

the

original

manufacturer

warranty);

• operations carried out by non-specialised personnel;
• unauthorized modifications or operations;
• missing, lack or inadequate maintenance;
• improper machine use;
• unforeseeable extraordinary events;
• use of the machine by uninformed and / or untrained

personnel;

• non-application of the current provisions in the country of

use, concerning safety, hygiene and health in the workplace.

The Manufacturer declines any liability for damage caused by
arbitrary modifications and conversions carried out by the user
or the Customer.
The employer, workplace manager or service technician are
responsible for identifying and choosing adequate and suitable
personal protection equipment to be worn by operators, in
compliance with regulations in force in the country of use.
The Manufacturer declines any liability for inaccuracies con-
tained in the manual, if due to printing or translation errors.
Any supplements to the installation, use and maintenance
manual the Customer receives from the Manufacturer will form
an integral part of the manual and therefore must be kept
together with it.

C.6

Copyright

This manual is intended solely for consultation by the operator
and can only be given to third parties with the permission of
UNIC SAS.

C.7

Keeping the manual

The manual must be carefully kept for the entire life of the
machine, until scrapping. The manual must stay with the
machine in case of transfer, sale, hire, granting of use or
leasing.

C.8

Recipients of the manual

This manual is intended for:

• the employer of machine users and the workplace manager
• operators for normal machine use
• specialised technicians - Customer Care service (see

service manual).

UNIC SAS
Z.I. 4ème rue - B.P. 425
06515 CARROS Cedex (France)

-  N°

Volts        V~

V 3N~

Hz

W

A

Amp      A
Water supply      MPa Max
Steam pressure      MPa Temperature      °C
Water Pressure      MPa. Water Pressure max      MPa

-  N°

Volts        V~

V 3N~

Hz

W

A

Amp      A
Water supply      MPa Max
Steam pressure      MPa Temperature      °C
Water Pressure      MPa. Water Pressure max      MPa

-  N°

Volts        V~

V 3N~

Hz

W

A

Amp      A
Water supply      MPa Max
Steam pressure      MPa Temperature      °C
Water Pressure      MPa. Water Pressure max      MPa

Summary of Contents for STELLA EPIC 3

Page 1: ...STELLA EPIC EN User manual Original instructions SE9020 2021 01...

Page 2: ...2 Installation diagram EPIC 2 790 730 5 3 mini 790 310 350 410 395 270 300 50 mini 50mini AVANT FRONT EI DO CWI x a m 5 9 1 515 0 0 7 682 50 mini 699 3 1 5 3 0 1...

Page 3: ...3 Installation diagram EPIC 3 x a m 5 9 1 515 0 0 7 682 50 mini 699 3 1 5 3 0 1 980 920 53 mini 980 310 350 410 300 470 270 50 mini 50 mini AVANT FRONT EI CWI DO...

Page 4: ...4 DO Drain outlet EI Electricity inlet CWI Cold water inlet G 3 8...

Page 5: ...ine is used so that it is always at hand for consultation in case of doubts or whenever required If after reading this manual there are still doubts regarding machine use do not hesitate to contact th...

Page 6: ...opyright 13 C 7 Keeping the manual 13 C 8 Recipients of the manual 13 D NORMAL USE 14 D 1 Characteristics of personnel enabled to operate on the machine 14 D 2 Characteristics of personnel trained for...

Page 7: ...hine Keep all packaging and detergents away from children Cleaning and user maintenance shall not be made by children without supervision For suitable personal protection equipment refer to chapter A...

Page 8: ...required PPE Failure to use the personal protection equipment by operators specialized personnel or users can involve exposure to chemical risk and cause possible damage to health depending on the mod...

Page 9: ...me where repair work has been carried out or new devices fitted water meters etc let the water flow until it is clean and clear The dynamic water pressure minimum and maximum must be between 1 bar 0 1...

Page 10: ...ent Put the appliance in safe conditions before starting any maintenance operation Disconnect the appliance from the power supply and carefully unplug the power supply cable if present Depending on th...

Page 11: ...ing do not oil lubricate repair and adjust moving parts do not remove the safety devices do not use water to extinguish fires placed on electrical parts Danger Meaning caution hot surface danger of el...

Page 12: ...ns carried out with the electrical panel powered Crushing or injury The specialised personnel may not correctly fix the control panel when accessing the technical compartment The panel could close sud...

Page 13: ...operation and invalidates the original manufacturer warranty operations carried out by non specialised personnel unauthorized modifications or operations missing lack or inadequate maintenance imprope...

Page 14: ...ck motor breakdowns worn electrical cable sheathing etc the operator for normal machine use must E TECHNICAL CHARACTERISTICS E 1 Data table ELECTRIC SUPPLY POWER Watt I single phase A I three phases n...

Page 15: ...e containing a summary of the information relating to the whole of the machine in real time Direct controls for a Level 0 user 2 Cleaning icon to access all available operations of cleaning and flushi...

Page 16: ...G 1 Cleaning groups G 1 1 Before use or after several hours of inactivity Drain for each unit and water outlet 0 5 liter of water for each steam outlet steam for 1 minute IMPORTANT Before preparing a...

Page 17: ...hol for the stainless steel parts and a nonabrasive cleaning agent for the painted parts Simply take care not to scratch the painted parts Keyboards cleaning IMPORTANT Never clean keyboard with liquid...

Page 18: ...only I 3 Use I 3 1 Automatic mode To reach the programmed T One impulse on the touch makes the Steamair flow until the liquid reaches the preset temperature You can stop it manually by pushing again...

Page 19: ......

Page 20: ...Z I 4e RUE BP 425 06515 CARROS CEDEX 1 FRANCE Tel 33 04 92 08 62 60 Fax 33 04 93 29 24 23 www unic sa com...

Reviews: