7) EXTENSION CABLE SELECTION
The machines are factory fitted with a 9-foot length of cable having three conductors 1.5 mm²
LIVE, NEUTRAL and EARTH. If it becomes necessary to fit an extension cable from the power source, care
must be taken in using a cable of adequate capacity. Failure to do so will result in a loss of traction by the
magnet and a reduction of power from the motor.
If the replacement of the supply cord is necessary, this must be done by the manufacturer or an approved
agent in order to avoid a safety hazard.
Assuming a normal AC supply of the correct voltage, it is recommended that the following extension lengths
shall not be exceeded:
For 120v supply: 11 ½ feet of 3 core x 16AWG
ALWAYS DISCONNECT THE MACHINE FROM THE POWER SOURCE BEFORE CHANGING CUTTERS.
8) MOUNTING OF CUTTERS
▪
The machine has been made to accept cutters having
¾”
dia. Weldon shanks.
The following procedure is to be used when mounting cutters:
▪
Lay the machine on its side with feed handles uppermost, ensuring arbor is wound down to its lowest
point to enable access to socket screws.
▪
Take appropriate pilot and place through the hole in cutter shank. Insert shank of cutter into bore of
arbor, ensuring alignment of two drive flats with socket screws.
▪
Tighten both screws using hexagon key.