VED24 User Manual
16
Operator
Controls
VED24
Front
Operator
Controls
Please Refer to Figure 3.
1.
POWER
LED indicator.
A green LED indicating that DC power is being provided to the unit.
2.
DRIVER
LED indicator.
A green LED indicating when the internal shutter driver circuit input has an active signal
present.
3.
SYNC
LED
indicator.
Indicates the status of Solid State Synchronization output. This green LED is illuminated
when shutter's electronic SYNC sensor is activated. This LED functions only if the shutter
used is equipped with the Solid State Synchronization system.
4.
N.O./N.C
.
Toggle switch.
The N.O./N.C. switch acts to invert the shutter operation. The position of this switch
determines shutter status BEFORE a trigger signal is received by
VED24
. In the N.C.
position the shutter will be triggered open by an input pulse signal. In the N.O. position the
shutter will be triggered closed.
5.
PULSE INPUT
BNC.
Allows control of the shutter’s exposure and frequency from a TTL signal source. The pulse
duration determines the shutter exposure interval. The frequency of the signal presented to this
input determines the frequency of shutter exposures. This input is active low.
6.
FUNCTION
Switches: Four edge actuated piano-DIP slide switches.
a.
Switch
1
is used to select the LOCAL or REMOTE status of the controller. The LOCAL
(up) control disables COM PORT (USB) communication; the BNC PULSE INPUT and
N.O./N.C. switch are enabled. The REMOTE (down) enables the COM PORT (USB)
communication; the BNC PULSE INPUT and N.O./N.C. switch are disabled.
b.
Switch
2
is used to select the voltage level provided to the internal shutter driver.
Standard +10.7VDC is provided in the (up) position, +18VDC is provided in the (down)
position. The chart in Table #2 indicates the voltage level for the particular shutter used.
c.
Switch
3
allows the user to select between bi-stable (up) and uni-stable (down) modes.
The chart in Table #2 indicates the voltage level for the particular shutter used.
d.
Switch
4
allows selection of the PULSE SET as indicated in Table #3. Pulse set #1 is
selected with this switch in the (up) position. Pulse set #2 is selected with this switch in
the (down) position. See Table #3
for a summary of the timing selections available.
7.
PULSE DURATION
Rotary Switch:
Rotation of the 8-position octal rotary switch (labeled 0 to 7) selects the duration of the drive
pulses to the shutter. These timing selection values are determined by the setting of
FUNCTION SWITCHES #3 and #4. See Table #3 for a listing of timing selections
available. This will allow a total of 16 timing selections for bi-stable shutters and 16
selections for uni-stable shutters. A total of 32 timing selections are available.
Summary of Contents for VincentAssociates VED24
Page 1: ...User Manual VED24 Shutter Driver 14 0071 Version 1 40 2020 1 800 828 6972 ...
Page 16: ...VED24 User Manual 15 Figure 2 PS24 24VDC Power Supply Overall Dimensional Layout ...
Page 18: ...VED24 User Manual 17 Figure 3 VED24 Front Panel Layout ...
Page 20: ...VED24 User Manual 19 Figure 4 VED24 Rear Panel Layout ...