![UNI ACP Series Technical And Operational Manual Download Page 4](http://html2.mh-extra.com/html/uni/acp-series/acp-series_technical-and-operational-manual_3658627004.webp)
1-4 FEATURES & SPECIFICATIONS
●
Features
- CPU Control
- Amplifier Mod. Type
- Digital Control
- RS-232C Interface
-
0.01% Frequency Stability
-
0.5% Less Load Regulation
-
1% Less Harmonic Distortion
●
Specifications
Spec. / Model
ACP-200 ACP-500 ACP-1K
ACP-2K
ACP-3K
ACP-5K
ACP-10K
Output Capacity
200VA
500VA
1KVA
2KVA
3KVA
5KVA
10KVA
Circuit Type
Multi Inverter Power Amplifier Mod. Type
Output Frequency
40-999Hz(Option : 1000~3000Hz,0.1Hz Step)
Frequency Stability
Less than
±
0.01%
Output Voltage
0-300V (Option : 0~500V), 1Phase or 3Phase
Load Regulator
Less than
±
0.5%
Current Limit
L : 1.3A
H : 0.66A
L : 3.33A
H : 1.66A
L : 6.67A
H : 3.33A
L : 13.3A
H : 6.67A
L : 20A
H : 10A
L : 33.3A
H : 16.6A
L : 66.6A
H : 33.3A
Output Waveform
True Sine Wave
Frequency Meter
LED Digital Display / Resolution : 0.1Hz
Volt/Ampere Meter
TRUE RMS LED Digital Display
Harmonic Distortion
Less than
±
1% at 40Hz to 999Hz
Input Voltage /
Frequency
110V/220V/380V, 1Phase or 3Phase(
±
10%), 50/60Hz
Dimension
(W
×
H
×
Dmm)
44*42*18 44*42*25
47*70*60
50*72*80 50*90*100
60*100*120
Insulation Voltage
AC 1500V (Within 1 Minute)
Insulation
Resistance
DC 500V
Protector
Electronic Circuit / Overload, Short Circuit
Temperature
0 ~ 40
℃
Humidity
0 ~ 90%