SECTION 1
GENERAL
AND SPECIFICATIONS
1-1 INTRODUCTION
The AC Power Source ACP series use state of the art PAM (Power Amplitude Modulation)
technology to provide a pure and stable alternating current (A.C.) power to the loader at very
low cost never achieved before. The model offers maximum rated power with Variable Voltage
Variable Frequency for any output voltage 0 to 300VAC with single phase, at any frequency
from 40 to 999Hz. It is not only suitable for commercial applications (47-63Hz), but also for
avionics, marine and military applications at 400Hz.
The output voltage is a complete semiconductor variable type (booster amplification control
type). The output frequency of 50Hz, 60Hz and 400Hz, which is used very frequently, is set with
Frequency Selector Switch. Any frequency from 40 to 999Hz is to be selected using Push
Wheel Digital Switch.
The cooling system for this model is a compulsory air-cooling type using cooling fin. The
output voltage is down or the over load LED is lit when the cooling fin is over heated or the
output is overloaded.
☞
OPTION
: The variable frequency range from 1,000Hz to 3,000Hz is provided as a option.
The desired frequency is to be set using the Volume Switch on front panel after
Selector Switch is on SET, Digital Switch is on 999 and X1 & X10 is on X10.
1-2 APPLIED STANDARDS
●
ANSI (American National Standards Institute)
●
IEEE (Institute of Electrical and Electronic Engineers)
●
K.S. (Korean Standards)
1-3 ENVIRONMENTAL CONDITIONS
●
Operating Temperature : 0 ~ 40
℃
●
Installation Place : Indoor
●
Relative Humidity : Less than 90 % (Non-Condensing)
●
Altitude : Less than 1,000 Meters above the sea level