Uni-Trend BTM-16K User Manual Download Page 4

2. Structure

Item 





Description 

USB (Type-C) interface 

SD card slot 

Interface cover 
LED light 

Infrared camera lens 

Visual light camera lens 
Trigger 

LCD display 
Power button 

Item 

10 

11 

12 
13 
14 
15 
16 
17 
18 


10 

11 

12 

Description 

13 

14 

15 

16 

17 

Flashlight button 
Left button 

Down button 

Up button 
Replay button 
Right button 

Back button 
SET button 
Tripod mounting hole 

3.Display

Display size: 2.8" 

Display resolution: 320 (vertical) x 240 (horizontal) pixels 

Item 


Description 
Center point temperature 

Maximum temperature 

Self-calibration 

Minimum temperature point 
Main menu 

10 

Item  Description 

High temperature alert sign 

Maximum temperature point 

Temperature bar 

Battery status 

10 

Date and time 

Summary of Contents for BTM-16K

Page 1: ...P N 110401109196X BTM 16K Professional Thermal lmager User Manual ...

Page 2: ... and Liability Uni Trend guarantees that the product is free from any defect in material and workmanship within one year from the purchase date This warranty does not apply to damage caused by accident negligence misuse modification contamination or improper handling The dealer shall not be entitled to give any other warranty on behalf of Uni Trend If you need warranty service within the warranty ...

Page 3: ...t environment for 10 to 30 minutes before measuring The product tests the surface temperature of the object If temperature compensation is needed please adjust in the Settings menu The product has a self calibration function If the reading jumps quickly please read the temperature after it gets steady After measuring extremely high or low temperature objects please leave the product for 10 minutes...

Page 4: ...hlight button Left button Down button Up button Replay button Right button Back button SET button Tripod mounting hole 3 Display Display size 2 8 Display resolution 320 vertical x 240 horizontal pixels 2 3 4 Item 1 2 3 4 5 5 Description Center point temperature Maximum temperature Self calibration Minimum temperature point Main menu 10 9 8 7 6 Item Description 6 High temperature alert sign 7 Maxim...

Page 5: ...on 3 Press the SET button to enter the Measurement menu 4 Press the up down button to select Center Spot center point measurement or Hilo Spot maximum and minimum temperature measurement 5 Press the SET button to turn on off Center Spot or Hilo Spot 6 Press the back button to exit 7 5 2 Palette 1 Press the SET button to open the main menu 2 Press the left right button to select the option 3 Press ...

Page 6: ...ss the SET button to turn off the point Press the back button to exit 5 4 Image Mode 1 Press the SET button to open the main menu 2 Press the left right button to select the II option 3 Press the SET button to enter the Image Mode menu 4 Press the up down button to select the desired mode from Thermal infrared image Digital visual light image and Fusion image blending 5 Press the SET button to app...

Page 7: ...e 2020 03 16 15 39 Time for111 1t To set date and time Date and Time 2020 03 16 03 41 PM T1mr fo1rn 1t 1 Press the up down button to select the Date and Time option in the settings menu 2 Press the SET button to enter the Date and Time submenu 3 Press the left right button to select the parameter to be adjusted 4 Press the SET button to enter the parameter adjustment state 5 Press the up down butt...

Page 8: ...p down button to increase or decrease the value 6 Press the SET button to save the current setting 7 Press the back button to exit Note For emissivity values of common materials please refer to the Common Emissivity 13 5 5 6 Display Brightness To set display brightness Display brightness Low 1 Press the up down button to select the Display Brightness option in the Settings menu 2 Press the SET but...

Page 9: ...back button to exit Note Do not remove or insert the SD card in saving pictures It is recommended to save no more than 1000 pictures so as not to affect the response speed of the product When the number of pictures exceeds 1 000 please clean up the SD card in time 15 5 5 10 System Settings System settings 0 Device information C Factory reset Iii Format sdcard To enter System Settings submenu 1 Pre...

Page 10: ......

Page 11: ...are refer to UNI T Documents Download Operation Guide 2 Connect the USB cable to the PC 3 Set the USB mode to USB Disk to browse pictures and analyze data through the PC software set the USB mode to USB Camera to realize real time image projection through the PC software 4 Regarding the usage of the PC software retrieve the Software User Manual from the Help option of the operation interface Note ...

Page 12: ...attery life 6 hours Center point temperature high Charging time 5 hours temperature tracking default Charging voltage current 5V 2A 7 Specifications Sensor Temperature range Measurement resolution Accuracy Optimal measuring distance Response time IR resolution Pixel size Color palette Infrared spectral band Field of view FOV Spatial resolution IFOV Thermal sensitivity NETO Frame rate Temperature m...

Page 13: ...missivity Wood 0 85 Black paper 0 86 Water 0 96 Polycarbonate 0 8 Brick 0 75 Concrete 0 97 Stainless steel 0 14 Copper oxide 0 78 Tape 0 96 Cast iron 0 81 Aluminum plate 0 09 Rust 0 8 Copper plate 0 06 Gypsum 0 75 Black aluminum 0 95 Paint 0 9 Human skin 0 98 Rubber 0 95 Asphalt 0 96 Soil 0 93 PVC 0 93 Note This manual can be downloaded from the official website of Uni Trend refer to UNI T Documen...

Reviews: