1. Safety Instructions ---------------------------------------------------------- 4
2. Structure -----------------------------------------------------------------------5
3. Display ------------------------------------------------------------------------- 6
4. Power On/Off ---------------------------------------------------------------- 6
5. Menu Introduction ---------------------------------------------------------- 7
6. Operating Instructions ----------------------------------------------------- 8
7. USB mode ------------------------------------------------------------------ 16
8. Specifications -------------------------------------------------------------- 17
9. Maintenance --------------------------------------------------------------- 19
10.Common Emissivity ------------------------------------------------------ 19
To ensure proper use of this product, please read the instructions carefully
before using.
To ensure measurement accuracy, please use the product in an operating
environment of 0°C~50°C, <85% RH (non-condensing).
When changing to a new environment, please turn on the product and leave
it for 10 to 15 minutes before measuring.
The ambient temperature for measuring must be stable. Do not measure in
places with large airflow such as fans and air outlets.
When the measured object comes from a place with a large temperature
difference from the measurement environment, keep it in the measurement
environment for 10 to 30 minutes before measuring.
The product tests the surface temperature of the object. If temperature
compensation is needed, please adjust in the Settings menu.
The product has a self-calibration function. If the reading jumps quickly, please
read the temperature after it gets steady.
After measuring extremely high or low temperature objects, please leave the
product for 10 minutes before next use.
Do not use the product in places with strong sunlight or electromagnetic
interference.
Please do not use this product in flammable, explosive, steamy, wet or corrosive
environments.
Please stop using the product if it is damaged or modified to avoid inaccurate
measurement results.
Please use the correct emissivity to obtain accurate temperature readouts.
To ensure accuracy of the product, please warm it up for 10 minutes before
measuring if it has not been used for a long time.
When being charged, the internal temperature of the product rises, which will
lead to inaccurate temperature measurement. So, it is not recommended
to take measurements during or right after charging the product.
The inherent temperature drift of the sensor will occasionally cause inaccurate
measurement. In this case, press the down button under the temperature
measurement interface to bring out “Calibrating” and automatically calibrate
the temperature.