background image

10

9

To track center point: 

1. Press the SET button to open the main menu.
2. Press the left/right button to select the      option. 
3. Press the SET button to enter the cursor submenu.
4. Press the up/down button to select the      option. 
5. Press the SET button to confirm.
6. The center point marker is turned on. 
7. Press the back button to exit the current menu.

To track high/low temperatures: 

1. Press the SET button to open the main menu.
2. Press the left/right button to select the      option. 
3. Press the SET button to enter the cursor submenu.
4. Press the up/down button to select the      option. 
5. Press the SET button to confirm.
6. The high/low temperature indicators are turned on and the corresponding 
    temperatures are displayed beside them.
7. Press the back button to exit the current menu.

6.3 Color Palette Selection

1. Press the SET button to open the main menu. 
2. Press the left/right button to select the      option. 
3. Press the SET button to enter the color palette submenu.
4. Press the up/down button to select the desired color from Iron Red, Rainbow, 
   Grayscale, Red-White, and Blue-White.
5. Press the back button to exit the current menu.

6.4 High/Low Temperature Alarm

To enable high/low temperature alarm:

1. Press the SET button to open the main menu.
2. Press the left/right button to select the       option. 
3. Press the SET button to enter the high/low temperature alarm submenu.
4. Press the up/down button to select HI (High) or LO (Low).
5. Press the SET button to confirm.
6. Press the back button to exit the current menu.

Note: 

High temperature alarm and low temperature alarm can be enabled 

simultaneously or separately.

UTi165A User Manual

UTi165A User Manual

Summary of Contents for UTi165A

Page 1: ...UTi165A Professional Thermal Imager P N 110401108897X ...

Page 2: ...rantees that the product is free from any defect in material and workmanship within one year from the purchase date This warranty does not apply to damages caused by accident negligence misuse modification contamination or improper handling The dealer shall not be entitled to give any other warranty on behalf of Uni Trend If you need warranty service within the warranty period please contact your ...

Page 3: ... if it is damaged or modified to avoid inaccurate measurement results Please use the correct emissivity to obtain accurate temperature readouts To ensure the accuracy of the product please warm it up for 10 minutes before measuring if it has not been used for a long time When being charged the internal temperature of the product will rise which will lead to inaccurate temperature measurement So it...

Page 4: ...n Up button SET button 3 Display Display size 2 8 Display resolution 320 vertical x 240 horizontal pixels 1 2 3 4 5 6 7 8 9 10 11 12 13 Description Temperature unit option Cursor option Color palette option High Low temperature alarm option Settings option Minimum temperature Maximum temperature Description Minimum temperature point Maximum temperature point Center point Center point temperature D...

Page 5: ... Press the up down button to select C or F 5 Press the back button to exit the current menu Main menu Submenu Temperature unit option Cursor option Color palette option High Low temperature alarm option Settings option 6 Operating Instructions 6 1 Temperature Unit Selection 5 Menu Introduction 6 2 Center Point and High Low Temperature Tracking UTi165A User Manual UTi165A User Manual ...

Page 6: ...de them 7 Press the back button to exit the current menu 6 3 Color Palette Selection 1 Press the SET button to open the main menu 2 Press the left right button to select the option 3 Press the SET button to enter the color palette submenu 4 Press the up down button to select the desired color from Iron Red Rainbow Grayscale Red White and Blue White 5 Press the back button to exit the current menu ...

Page 7: ...u 2 Press the SET button to enter the Date Time submenu 3 Press the left right button to select the parameter to be adjusted 4 Press the SET button to enter the parameter adjustment state 5 Press the up down button to increase or decrease the value 6 Press the SET button to save the settings and return to set other parameters 7 Press the back button to exit the current menu 6 5 3 Emissivity To set...

Page 8: ...ress the back button to exit the current menu 6 5 6 Temperature Bar To turn on off temperature bar 1 Select the Temp Bar option up down button in the settings menu 2 Press the SET button to enter the Temp Bar submenu 3 Press the up down button to select On or Off 4 Press the SET button to confirm 5 Press the back button to exit the current menu 6 5 7 Alarm Temperatures To set alarm temperatures 1 ...

Page 9: ...to confirm 5 Press the back button to exit the current menu 6 5 10 Format SD Card To format SD card 1 Select the Format SD option up down button in the settings menu 2 Press the SET button to enter the Format SD submenu 3 Press the up down button to select Yes 4 Press the SET button to confirm 5 Press the back button to exit the current menu 6 5 11 Auto Save To turn on off auto save 1 Select the A...

Page 10: ...w grayscale red white blue white 8μm 14μm 56 H 42 V 11mrad 50mK 9Hz BMP General parameters PC software Data transmission Product size L x W x H Display type Display resolution Battery Auto power off Battery life Charging time Charging voltage current Image storage Drop test IP rating Certification Storage temperature Operating temperature Operating humidity Altitude Standard accessories Yes Type C...

Page 11: ...al Emissivity 0 85 0 96 0 75 0 14 0 96 0 09 0 06 0 95 0 98 0 96 0 93 Material Black paper Polycarbonate Concrete Copper oxide Cast iron Rust Gypsum Paint Rubber Soil Emissivity 0 86 0 8 0 97 0 78 0 81 0 8 0 75 0 9 0 95 0 93 Note This manual can be downloaded from the official website of Uni Trend refer to UNI T Documents Download Operation Guide Emissivity of common objects ...