Mode l UT71C/D/E: OPERATING MANUAL
K. 4~20 mA loop curre n t
Range
(4~20mA)%
Resol u t i o n
0.01%
Acc ur a c y
(1%+50)
Overloa d Prote c t i o n
0.5A, 250V, fast type fuse, 5×20mm
Remar k s:
When the readings obtained is:
l
< 4mA, the primary display shows LO
l
4mA, the primary display shows 0% ….
20mA, the primary display shows 100%
l
> 20mA, the primary display shows HI
L. Powe r Measure m e n t (UT71E only)
Range
2500W
Resolu t i o n
0.1W
Ac cu r a c y
(2%+50)
Curren t Overl oa d Prote c t i o n
10A, 250V, fast type fuse, 5×20mm
Vol ta g e Overload Prote c t i o n
1000V
Remar k s:
l
Power factor input range: 0.00~1.00
l
Voltage input impedance: around 10M .
l
Voltage input range: AC50~250V
** END **