1. Make sure engine is off.
2. Connect to the correct polarity.
3. Select “Charge”
7 16V DC
~
264g
76mm*22mm*142mm
CCA:40 2000; BCI 40 2000; CA 40 2000 MCA
40~2000; JIS:26A17~245H52; DIN:40~1400; IEC:
40~1400; EN:40~2000;SAE:40~2000; AH:3~250 AH
~
:
~
:
~
;
:
UT673A
UT675A
175mm*45mm*320mm
285mm*90mm*230mm
95mm*47mm*183mm
413g
Model
Applicable battery
Battery type
Battery capacity
Battery standard
and range
Voltage range
Test method
AH rapid measurement
Overvoltage protection
Prevent counter voltage
A prompt of poor contact
Internal resistance measurement
Battery life
Remaining battery capacity
USB data transfer
Printing function
LCD
Language
3 250AH
~
Four-terminal kelvin test lead
/
/
LCD (128*64 black and white lattice)
Chinese and English
General
0°C 50°C
~
Operating: below +35°C,
≤
90%
Non-operating: +35°C +40°C,
≤
60%
~
Temperature
Relative
humidity
Working
environment
Net weight
(excluding batteries)
Product dimension
(excluding test leads)
Packing box dimension
View test result
a) For UT673A, ENTER to view the last test result of Battery test, Cranking and
Charging system test.
b) For UT675A, ENTER to view and export the last test result of Battery test, Cranking
and Charging system test. Connect the computer to export the last test result via
serial port and print the result.
Note:
Please find the application software on our website by searching UT675A and
search under Docs & Software section.
About
(Applicable to UT673A)
ENTER to view system information.
Print test result
(Applicable to UT675A)
ENTER to print the last test result of Battery test, Cranking and Charging system test.
Note:
The normal working voltage of the printer is 10 16V.
~
Setting
ENTER to select language (English or Chinese).
Function
ENTER to enter setting page.
Language selection
User can select desired language as needed. After entering language selection page,
press ENTER to select English or Chinese.
Time adjustment
(Applicable to UT675A)
User can adjust or correct the system time, time sequence adjustment (Year/Month/Day
/Hour/Minute) does not affect the setting of date and time format.
a. Press up or down button to adjust the last two digits of the YEAR, then press ENTER
to confirm this adjustment and enter month adjustment.
b. Press up or down button to adjust Month, then press ENTER to confirm this adjustment
and enter date adjustment.
c. Press up or down button to adjust DATE, then press ENTER to confirm this adjustment
and enter hour adjustment.
d. Press up or down button to adjust HOUR, then press ENTER to confirm this adjustment
and minute adjustment.
Specification
3. Charging test
Battery
Crank
Charge
Data
Setting
About
Battery
Charge
Data
Setting
UT675A
UT673A
4. Enter the interface
of starting engine.
5. Start engine.
6. Start ripple test.
***
LOADED TESTING
Crank
CHARGING TEST
START ENGINE
RIPPLE TEST
PRESS ENTER TO
CONTINUE
5mV 12.65V
Test results:
Interpretation
Charging system is normal, the output
voltage of engine is 13.5V 14.7V.
~
Charging system is under-voltage,
the voltage is lower than 13.5V.
The voltage of charging system is higher
than that of vehicle voltage stabilizer.
Generator voltage output is not detected.
Check if the connector and generator belt is normal.
Test via current waveform, for example, the diode is
damaged due to high ripple voltage of diode.
Decision
Charging voltage is normal.
Charging voltage is low.
Charging voltage is high.
No voltage output.
Diode test.
12V cranking lead acid battery
Ordinary lead acid battery, AGM flat plate battery,
AGM spiral battery, GEL battery, EFB battery.
Cranking test
Charging test
12/24V cranking system test
12/24V charging system test
7. Start loaded testing
INCREASE RPM TO
2500 R/MIN AND
KEEP IT 5 SECONDS
PRESS ENTER TO
CHARGING NORMAL
LOADED 14.26V
UNLOADED 12.65V
RIPPLE 5mV
8. According to the prompt, Step
on accelerator to increase the
engine speed to 2500 R/Min and
hold for 5 seconds.
9. Display test result.
Test results
Interpretation
The starting voltage is higher than 9.6V.
The starting voltage is lower than 9.6V.
Decision
Starting voltage is normal.
Starting voltage is low.
e. Press up or down button to adjust MINUTE, then press ENTER until “OK” is displayed.
After finishing the adjustment, the tester will go back to main interface. When adjusting
the time, the time character will flash. By pressing and holding the button, the character
will increase or decrease continuously.
NOTE:
Make sure the button is pressed for more than one second when adjusting time.
After entering time setting, pressing return button is disabled because the system time
is protected, users need to set Year/Month/Day/Hour/Minute or press return button 5
times to return.
UT675A
UT673A
Maintenance
1. Do not put or store the tester in the place where its LCD is exposed to direct sunlight
for a long time. No sprays, liquids or solvents are allowed on the tester or fixtures.
2. Please clean the dust on the tester with soft cloth. Do not scratch the protection
screen of LCD. Wipe the tester with a damp but non-dripping soft cloth. Never use
any corrosive chemical detergents.
Warning: Before the tester is powered on, please make sure it is completely dry to
avoid short circuit caused by moisture.
Tester host: 1 piece
User manual: 1 piece
USB cable: 1 piece
Printing paper: 3 pieces
Cloth bag: 1 piece
Tester host: 1 piece
User manual: 1 piece
Velcro strap: 1 piece
Accessories
https://www.uni-trend.com.cn/index.php?m=content&
c=index&a=show&catid=515&id=882