B-5 Resistance
200
Ω
2K
Ω
20K
Ω
200K
Ω
2M
Ω
20M
Ω
200M
Ω
0.01
Ω
0.1
Ω
1
Ω
10
Ω
100
Ω
1K
Ω
10K
Ω
Range
Resolution
Accuracy
(0.3% +1)
(0.5% +10)
(0.5% +1)
[5.0%(-1000) +10]
(0.3% +3)
Overload protection: All ranges are 250VDC
or AC RMS.
Caution:
1) At 200M
Ω
range, test lead is short circuit, the
LCD display 1000 digits, deduct the 1000
digits from the measured reading during
measuring.
2) At 200
Ω
range, short the test lead first to display
the resistance value of the test leads. Deduct
that resistance value from the measured reading
to obtain the being measured object correct
value .
B-6 Capacitance
Testing Signals: About 400Hz, 40mVrms.
2nF
20nF
200nF
2
µ
F
20
µ
F
0.1pF
1pF
10pF
0.1nF
1nf
Range
Resolution
Accuracy
(4% +20)