![UNI-T UT39E Operating Manual Download Page 22](http://html.mh-extra.com/html/uni-t/ut39e/ut39e_operating-manual_838927022.webp)
To replace battery:
1. Disconnect the connection between the testing leads
and the circuit under test, and remove the testing
leads away from the input terminals of the Meter.
2. Press the Meter power off
3. Remove the screw from the battery compartment, and
then take out the battery door from the battery
compartment.
4. Remove the battery from the battery compartment.
5. Replace the battery with a new 9V battery (NEDA
1604 or 6F22 or 006P).
6. Rejoin the battery door and the battery compartment,
and install the screw
C. Replacing the Fuses
(see figure 10)
( figure 10)
SCREW
Warning
To avoid electrical shock or arc blast, or personal
injury or damage to the Meter, use specified fuses
ONLY in accordance with the following procedure.
To replace the Meter’s fuse:
1. Disconnect the connection between the testing leads
and the circuit under test, and remove the testing
leads away from the input terminals of the Meter.
2. Press the Meter power off.
3. Remove the holster from the Meter.
4. Remove the screw from the battery compartment,
and then take out the battery door.
5. Remove the screw inside the battery compartment
and also the other two screws from the case bottom,
and then separate the case bottom from the case top.
6. Remove the fuse by gently prying one end loose, and
then take out the fuse from its bracket.
22
Model UT39E: OPERATING MANUAL