8. Maintenance and Cleaning

    The ingress protection rating of UT320T thermometer is lP54. The housing and 
    probe can be cleaned with a moist sponge or soft cloth. Please dry the product 
    after cleaning.
    Use a cotton swab soaked in water or medical alcohol to clean the surface of the 
    lens.

Measure

Stop measuring

Stop measuring

Place the thermometer at 0℃-50℃ 
(32℉-122℉) for 30 minutes. If Err 
is still displayed, the product needs 
to be repaired.

Replace batteries

Restart the product or reinstall the 
batteries and then restart it. If the 
product still does not operate 
normally, repair it.

Refer to Field of View, D: S and 
other instructions in this manual.

Repair the probe if it is damaged.

Cause

Measured value>
maximum range

Measured value<
minimum range

Exceed the minimum/ 
maximum operating 
temperature or 
infrared sensor 
damage

Low battery

Internal damage

Too far measurement 
distance, diameter of 
the measurement 
target<12mm

Probe damage, insert 
the probe less than 
12.7mm into the 
measured object

Phenomenon

Display OL

Display -OL

Display Err 
(startup)

Battery symbol 
flashes

Display Er0 
(startup)

Inaccurate 
infrared 
measurement

Inaccurate 
probe 
measurement

9. Troubleshooting

10. Notice for Use

Infrared measurement:

    If the ambient temperature changes (e.g., from indoor to outdoor), the thermometer 
    should be allowed at least 30 minutes to stabilize, otherwise error may be caused.
    If there is dust or foreign matter on the lens of the infrared sensor, clean the lens 
    according to the method (8. Maintenance and Cleaning) and continue to measure 
    after the lens surface is dry.
    Make sure there are no other obstacles between the product and the measured 
    object.

Probe measurement:

    The probe has a minimum penetration depth of 12.7mm.
    Do not use the product in corrosive acids or alkalis.

Summary of Contents for UT320T

Page 1: ...P N 110401111770X UT320T 2 in 1 Thermometer User Manual...

Page 2: ...behalf of UNI T If you need warranty service within the warranty period please contact your seller directly This warranty is the only compensation you can obtain UNI T will not be responsible for any...

Page 3: ...should only be repaired by professional maintenance personnel using original replacement parts Replace the batteries when the low battery indicator shows to prevent incorrect measurements Please check...

Page 4: ...ty Value display Temperature difference Infrared Probe measurement Low battery Temperature units Maximum minimum temperature Infrared sensor Single laser LCD Scan l Hold Press it to turn on the thermo...

Page 5: ...0 or 0 01 t whichever is greater 40 t 32 32 t 572 Measuring range 40 300 40 572 Probe type Minimum measuring depth Operating time Accuracy Probe measurement NTC 12 7mm About 180h backlight on Over ra...

Page 6: ...e is unfolded the product automatically starts measuring Insert the probe at least 12 7mm into the measured object and wait for the value to stabilize before reading the temperature Press the Scan Hol...

Page 7: ...determine the temperature Objects of different materials have different emissivity The emissivity of most organic materials painted or oxidized surfaces is about 0 95 The user can use masking tapes or...

Page 8: ...n this manual Repair the probe if it is damaged Cause Measured value maximum range Measured value minimum range Exceed the minimum maximum operating temperature or infrared sensor damage Low battery I...

Reviews: