 Please press SELECT key to select the 3rd phase location of 

3 shown in Figure 12-3. It also can display frequency, voltage 

     and current of phase location of 

3.

Figure

Measurement operation of the 1st and 2nd phase locations is the same as that of three-phase 
four-wire system after tripping the 3rd phase location of measurement.

5

There is no measurement function of the maximum/minimum value for this function gear.

Note:

     1

It is not allowed to measure AC voltage of more than 600V

r.m.s

 and AC current of 

          1000A

r.m.s

.

     2

Not frequency of current signals but that of voltage signals shall be measured.

7.6Electric energy (kWh)+Active power (kW)+Time (h:m:s)

1

Press MENU key to select gear of 

electric energy (kWh)+active power(kW)+time (h:m:s)

;

2

Jaw shall be fixed to measured conduits in corresponding phase locations. That is, user shall 

      measure a certain phase of three-phase circuit so that jaw is on corresponding conduit.
3

Please refer to Figure 4, 5 & 6 of UT240 manual for wiring of three-phase four-wire system, 

      three-phase three-wire system or single-phase two-wire system.

 As shown in Figure 13, please press SELECT key to select 

     phase locations of

1

2

3 to display current power of 

     measured load for corresponding phase locations, current 
     statistic period and current accumulated electric energy on 
     LCD.

Figure

Accumulated electric energy increases gradually with time. User can press HOLD key to lock 
measurement value and measurement time display when reading electric energy for a certain 
period. However, instrument will continue to accumulate measurement time. Please press HOLD
key once again after reading data to continue to measure accumulated electric energy. 
Measurement time display will turn to current measurement time value and electric energy 
function will not stop until function conversion to positions of other gears. The maximum testing 
quantity of electric energy is 

9999kWh

. Display will show  OL symbol a fter e xceeding the

value. The maximum statistic period of electric energy also cannot exceed 99 hours.

4

There is no measurement function of the maximum/minimum value for this function gear.

5

Press CLEAR key to reset time and accumulated electric energy to begin counting & 

      measurement again.

UT241/242/243 OPERATING MANUAL

UT241/242/243 OPERATING MANUAL

Summary of Contents for UT241

Page 1: ...P N 110401103621...

Page 2: ...cteristics 2 3 Technical specifications 3 4 Instrument Layout 9 5 Key function 13 6 Preparation before measurement 16 7 Measurement function of electric energy 16 8 Harmonic measurement function 37 9...

Page 3: ...the operation manual especially safety content carefully before using instruments Safety Mark Please refer to manual for important safety marks HV danger Grounding Duplex insulation for Class II safet...

Page 4: ...active power inactive power and apparent power which contains harmonics for 20 times correctly To measure total harmonic distortion rate of voltage current signals for at most 20 times and harmonic c...

Page 5: ...ar ar ar ar ar ar ar ar ar Current Voltage current range Accuracy Resolution The maximum permissible overload protection voltage 600V r m s The maximum permissible overload protection current 1000A r...

Page 6: ...inimum value is 50V and the maximum value is 500V Other functions Display 4 bits of LCD with the maximum counting of 9 999 and multiplex display Range selection Automatic rangelOver range display OL A...

Page 7: ...y electric energy function selection key 6 LOAD key 7 SELECT key phase location selection key and total power measurement selection key 8 key 9 V3 end the 3rd phase location of measurement input end 1...

Page 8: ...otal three phase power 9 Symbol of the 3rd phase location 10 Symbol of the 2nd phase location 11 Symbol of the 1nd phase location 12 Main parameter unit 13 Unit of the 1st auxiliary parameter 14 Secon...

Page 9: ...undamental wave distortion rate and current harmonics Press the key for a long time to alter harmonic frequency mode temporarily under harmonic mode for invalidation after power off LIGHT UT241 Press...

Page 10: ......

Page 11: ...e testing pen and COM end black testing pen to every firing line of three phase load respectively during load measurement of three phase three wire system V3 end yellow testing pen also cannot be meas...

Page 12: ...2 please press key to measure total three phase power Current measured power of the 1st phase location also shall be calculated and saved Figure As shown in Figure 7 3 please press SELECT key to sele...

Page 13: ...ng measurement Please press the key for a long time to exit the maximum minimum value mode Note 1 Please do not measure AC voltage of more than 600 v r s and AC current of 1000A v r s 2 key does not e...

Page 14: ...our wire system As shown in Figure 8 8 total three phase apparent power can be displayed by pressing SELECT key after tripping the 3rd phase location of measurement Figure 5 The maximum measuring rang...

Page 15: ...Figure As shown in Figure 9 4 please press key to measure total three phase power Current measured power of the 2nd phase location also shall be calculated and saved Figure As shown in Figure 9 5 ple...

Page 16: ...stem three phase three wire system or single phase two wire system 4 As shown in Figure 10 1 please press SELECT key to select the 1st phase location of 1 for load of three phase four wire system It a...

Page 17: ...operation of the 1st and 2nd phase locations is the same as that of three phase four wire system after tripping the 3rd phase location of measurement 5 There is no measurement function of the maximum...

Page 18: ...tem or single phase two wire system As shown in Figure 13 please press SELECT key to select phase locations of 1 2 3 to display current power of measured load for corresponding phase locations current...

Page 19: ...1 As shown in Figure 15 16 17 instrument will display phase sequence detection result for load loop of three phase four wire system Figure 15 Any phase of voltage is less than 30V Figure 16 Inverted...

Page 20: ...ult Jack Inverted sequence Inverted sequence Figure 19 4 LCD will display default phase detection result if certain phase of voltage is less than 50V or without signal for three phase four wire system...

Page 21: ...tage for load of three phase four wire system Measurement steps Press HARM key to enter into measurement mode of total voltage harmonics to total wave distortion rate firstly after bootstrap and conne...

Page 22: ...in right lower corner respectively Figure 23 User can press key to increase harmonic order or press key to reduce harmonic order It also will display effective value of various voltage harmonic compo...

Page 23: ...loop cables of measured phase and loosen and guarantee excellent closing of binding clip Figure 24 As shown in Figure 25 user can press SELECT key to select No of any measurement port to display curre...

Page 24: ...rder It also will display effective value of various current harmonic components 8 6 Current Harmonics It will measure and display effective value of total harmonics of single phase current to fundame...

Page 25: ...2 20m 20 minutes 3 30m 30 minutes 4 OFF Automatic power off function is OFF 9 2 Setup of automatic OFF time of SE2 backlight As shown in Figure 29 user can press SELEST key for bootstrap and entry int...

Page 26: ...y according to following steps 1 Cut off testing circuit for testing pen press POWER key for power off and remove testing pen from input jack 2 Open cell cover of instrument and remove old battery and...

Page 27: ......

Reviews: