Measurement Operation

Before measurement, anticlockwise circumgyrate the 

red cover and rock the input terminal.

When  all  themeasurement  has  been  completed, 

deasil circumgyrate the red cover then hide the input 

terminal. (see figure 3)

 

                                

                               Figure 3   

1.  AC / DC Voltage auto Measurement

       Warning

To avoid harm to the Meter, never input higher than 

300V  voltage  although  it  is  possible  to  measure 

higher voltage.

To measure Voltage, connect the Meter as follows:

●  Set the switch to 

V       .

●  Auto measuremeng mode is a default. Under this 

    mode can measure AC voltage and DC voltage.

●  Connect the test leads across with the object 

    being measured. The measured value shows on 

    the display.

●  When voltage measurement has been completed, 

    disconnect the connection between the testing 

    leads and the circuit under test, and remove the 

    testing leads away from the input terminal of the 

    meter.

Note:

The threshold voltage of AC voltage is around 400mV.

2. DC Voltage Measurement

        Warning

To avoid harm to the Meter, never input higher than 

300V  voltage  although  it  is  possible  to  measure 

higher voltage.

●  Set the switch to 

V     .

●  Press SELECT to select DC voltage measurement 

    mode.

●  Connect the test leads across with the object 

    being measured. The measured value shows on 

    the display.

●  When voltage measurement has been completed, 

    disconnect the connection between the testing

    leads and the circuit under test, and remove the 

    testing leads away from the input terminal of the 

    meter. 

International Electrical Symbols

  

 Deficiency of Built-In Battery 

  

                   Grounding 

  

 AC (Alternative Current) 

  

                   DC (Direct Current)
                   Double Insulated 

  

  

                   Continuity Test
  

 AC or DC   

                   Diode
                   Conforms to Standards of European

  

 Warning. Refer to the Operating Manual

The Meter Structure

 (see figure 1)

1.   Front Housing             2.   Functional buttons

3.   Switch                         4.   LCD Display

5.   Input Terminals

Display Symbols 

(see figure 2)

  

                               Figure 2

1.   Indicates auto scan mode

2.   High voltage indicator

3    Data hold is active

4.   Indicates negative reading

5.   The meter is in the autorange mode

6.   Indicator for AC voltage 

7.   Indicator for DC voltage 

8.   The battery is low       

      Warning: To avoid false readings, which could 

lead to possible electric shock or personal injury, 

replace the battery as soon as the battery indicator 

appears.

9.   Minimum reading.

10.  Maximum reading.

11.  The unit of Capacitance 

12   Test of diode

13.  The continuity buzzer is on. 

14.  V : Volts. The unit of voltage.

       mV : Millivolt. 1x10   or 0.001 volts.

15.  Ω: Ohm. The unit of resistance

       kΩ : kilohm. 1x10   or 1000 ohms.

       MΩ: Megaohm. 1x10  or 1,000,000 ohms

Button function and auto power off

1.SELECT

Press 

SELECT

 to switch between resistance, AC/DC 

voltage, continuity buzzer and diode measurement 

modes. Press and hold more than 2 seconds in or 

exit “sleep” mode.

UT118A/B Operating Manual

Pen Type Meters 

UT118A/B

Operating Manual

Overview

This Operating Manual covers information on safety 

and cautions. Please read the relevant information 

carefully and observe all the Warnings and Notes 

strictly.

       Warning

To avoid electric shock or personal injury, read the 

"Safety Information" and "Rules for Safe Operation" 

carefully before using the Meter.

The Model UT118A and UT118B (hereafter referred 

to as “the Meter”) are 3000 counts pen type digits 

millimeters. The Meter uses large scale of integrated 

circuit with professional multimeter IC as its core and 

has full range overload protection.

The Meter measures or tests the following:

●   AC/DC voltage 

●   EF Function (UT118B only)

●   Resistance

●   Diode

●   Continuity

●   Capacitance

Unpacking Inspection

Open the package case and take out the Meter. 

Check  the  following  items  carefully  to  see  any 

missing or damaged p

art:

 Item    Description                              Qty

  1        English Operating Manual          1 piece
  2        Test Lead 

                           1 pair

In the event you find an

y missing or damage, please 

contact your dealer immediately.

Safety Information

This Meter complies with standards EN61010: in 

pollution degree 2, over voltage category (CATIII 

300V) and double insulation.

CATIII:  Distribution  level,  fixed  installation,  with 

smaller transient over voltages than CAT IV.

Use the Meter only as specified in this operating 

manual, otherwise the protection provided by the 

Meter may be impaired.

In  this  manual,  a  Warning  identifies  conditions 

and actions that pose hazards to the user, or may 

damage the Meter or the equipment under test.

A Note identifies the information that user should pay 

attention on.

Rules For Safe Operation

        Warning

To avoid possible electric shock or personal injury, 

and to avoid possible damage to the Meter or to the 

equipment under test, adhere to the following rules:

●   Before using the Meter inspect the case. Do not 

use the Meter if it is damaged or the case (or part 

of the case) is removed. Look for cracks or missing 

plastic. Pay attention to the insulation around the 

connectors.

●   Inspect the test leads for damaged insulation or 

exposed metal. Check the test leads for continuity. 

Replace damaged test leads with identical model 

number or electrical specifications before using the 

Meter.

●   When using the test leads, keep your fingers 

behind the finger guards.

●   Do not apply more than the rated voltage, as 

marked  on  the  Meter,  between  the  terminals  or 

between any terminal and grounding.

●   When the Meter working at an effective voltage 

over 60V DC or 30V AC, special care should be 

taken for there is danger of electric shock.

●      Use  the  proper  function,  and  range  for  your 

measurements.

●   Disconnect circuit power and discharge all high 

voltage capacitors before testing current, resistance, 

diodes or continuity.

●      Replace  the  battery  as  soon  as  the  battery 

indicator   appears. With a low battery, the Meter 

might produce false readings that can lead to electric 

shock and personal injury.

●      When  servicing  the  Meter,  use  only  the 

same  model  or  identical  electrical  specifications 

replacement parts.

●     The  internal  circuit  of  the  Meter  shall  not  be 

altered at will to avoid damage of the Meter and any 

accident.

●   Soft cloth and mild detergent should be used to 

clean the surface of the Meter when servicing. No 

abrasive and solvent should be used to prevent the 

surface of the Meter from corrosion, damage and 

accident.

●   Do not use or store the Meter in an environment 

of high temperature, humidity, explosive, inflammable 

and strong magnetic field. The performance of the 

Meter may deteriorate after dampened.

Figure 1

2. HOLD

Press 

HOLD

 to enter and exit hold mode (except 

under auto scan mode). 

Press  and  hold  the 

HOLD

  button  more  than  2 

seconds, the meter automatically holds the value 

which obtains at 6 seconds later, at this time,     is 

displayed and flickering.

If enter “sleep” mode under hold mode, the meter still 

in the hold mode when it be turned on.

3. MAX/MIN

The  MAX/MIN  mode  stores  minimum  (MIN)  and 

maximum (MAX) input values (except under auto scan 

mode). Manual ranging comes when you select this 

function.

Press 

MAX/MIN

 button MAX       MIN        MAX/MIN 

and vice versa.

Under hold mode and max/min mode, should exit hold 

mode first then press and hold MAX/MIN more than 1 

second to exit max/min mode.

4.   

Display Backlight and test lead light button, Press  

once to turn the display backlight and test lead light 

on and press again to turn the display backlight and 

test lead light off. It will automatically off after around 

1 minute.

5.  AUTO POWER OFF

To preserve battery life, the Meter automatically goes 

into a “sleep” mode if you do not press any button for 

around 10 minutes. The Meter can be activated by 

pressing any button, then returns to the display for the 

function selected previously

6.  BUZZER

The buzzer phonate go with every time button be 

effectual pressed. When the meter will auto power off 

in 20 seconds the buzzer beeps three times. Before 

power off there will be a long time buzzer beeps.

-3