background image

User Manual

Code: UT-213C

CLAMP METER UT-213C UNI-T

DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl
POL; 60-713 Poznań; Graniczna 10
e-mail: [email protected]; tel: +(48) 61 864 69 60

2021-10-04

UT-213C

2/6

The UT-213C is a universal digital meter equipped with
clamps  enabling  the  measurement  of  high  currents.
The  device  measures:  voltage,  current,  frequency,
resistance, capacity and temperature. In addition, the
meter has an electric field detection function (NCV).

The meter is equipped with the True RMS transducer
enabling accurate measurement of the RMS current
and  voltage  for  both  sinusoidal  and  distorted
waveforms.

DC voltage measurement:

400 mV ± (1% + 8)  @ 0.1 mV ,
4 V ± (0.8% + 1)  @ 0.001 V ,
40 V ± (0.8% + 3)  @ 0.01 V ,
400 V ± (0.8% + 3)  @ 0.1 V ,
600 V ± (1% + 3)  @ 1 V

AC voltage measurement:

4 V ± (1.2% + 5)  @ 0.001 V ,
40 V ± (1.2% + 5)  @ 0.01 V ,
400 V ± (1.2% + 5)  @ 0.1 V ,
600 V ± (1.5% + 5)  @ 1 V

DC current measurement:

40 A ± (2% + 3)  @ 0.01 A ,
400 A ± (2% + 3)  @ 0.1 A

AC current measurement:

40 A ± (2.5% + 5)  @ 0.01 A ,
400 A ± (2.5% + 5)  @ 0.1 A

Resistance measurement:

400 Ω ± (1.2% + 2)  @ 0.1 Ω ,
4 kΩ ± (1% + 2)  @ 0.001 kΩ ,
40 kΩ ± (1% + 2)  @ 0.01 kΩ ,
400 kΩ ± (1% + 2)  @ 0.1 kΩ ,
4 MΩ ± (1.2% + 3)  @ 0.001 MΩ ,
40 MΩ ± (2% + 5)  @ 0.01 MΩ

Capacitance measurement:

40 nF ± (4% + 25)  @ 0.01 nF ,
400 nF ± (4% + 5)  @ 0.1 nF ,
4 µF ± (4% + 5)  @ 0.001 µF ,
40 µF ± (4% + 5)  @ 0.01 µF ,
400 µF ± (4% + 5)  @ 0.1 µF ,
4 mF ± (10%)  @ 0.001 mF
40 mF @ 0.01 mF

Inductance measurement:

Frequency measurement:

10 Hz ... 1 MHz ± (0.1% + 4)  @ 0.01 Hz ... 1 kHz ± (0.1% + 4) 

Summary of Contents for UT-213C

Page 1: ...t factor The device must be secured against contact with caustic staining and viscous fluids The device was designed in such a way that it restarts operation when power supply is restored after a break Turn off the device before transporting it Prior to connecting the device to a power source check whether the supplied voltage is consistent with rated voltage specified in the user manual Attention...

Page 2: ... the RMS current and voltage for both sinusoidal and distorted waveforms DC voltage measurement 400 mV 1 8 0 1 mV 4 V 0 8 1 0 001 V 40 V 0 8 3 0 01 V 400 V 0 8 3 0 1 V 600 V 1 3 1 V AC voltage measurement 4 V 1 2 5 0 001 V 40 V 1 2 5 0 01 V 400 V 1 2 5 0 1 V 600 V 1 5 5 1 V DC current measurement 40 A 2 3 0 01 A 400 A 2 3 0 1 A AC current measurement 40 A 2 5 5 0 01 A 400 A 2 5 5 0 1 A Resistance ...

Page 3: ...ing ranges Diode test Sound signal of the continuity test RS 232 USB Main features True RMS accurate measurement of the RMS current and voltage for any waveform NCV electric field detection function REL relative measurement mode Writing the value MAX MIN Hold stopping the meter reading Flashlight built in Large readable LCD display with backlight Low battery level alarm Aesthetic and solid constru...

Page 4: ... UT 213C CLAMP METER UT 213C UNI T DELTA OPTI Monika Matysiak https www delta poznan pl POL 60 713 Poznań Graniczna 10 e mail delta opti delta poznan pl tel 48 61 864 69 60 2021 10 04 UT 213C 4 6 Front panel Connectors ...

Page 5: ...ETER UT 213C UNI T DELTA OPTI Monika Matysiak https www delta poznan pl POL 60 713 Poznań Graniczna 10 e mail delta opti delta poznan pl tel 48 61 864 69 60 2021 10 04 UT 213C 5 6 Side view Place for batteries 3 x 1 5V AAA In the kit ...

Page 6: ...13C CLAMP METER UT 213C UNI T DELTA OPTI Monika Matysiak https www delta poznan pl POL 60 713 Poznań Graniczna 10 e mail delta opti delta poznan pl tel 48 61 864 69 60 2021 10 04 UT 213C 6 6 Device is secured by handy case ...

Reviews: