User Manual
Code: UT-213C
CLAMP METER UT-213C UNI-T
DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl
POL; 60-713 Poznań; Graniczna 10
e-mail: [email protected]; tel: +(48) 61 864 69 60
2021-10-04
UT-213C
2/6
The UT-213C is a universal digital meter equipped with
clamps enabling the measurement of high currents.
The device measures: voltage, current, frequency,
resistance, capacity and temperature. In addition, the
meter has an electric field detection function (NCV).
The meter is equipped with the True RMS transducer
enabling accurate measurement of the RMS current
and voltage for both sinusoidal and distorted
waveforms.
DC voltage measurement:
400 mV ± (1% + 8) @ 0.1 mV ,
4 V ± (0.8% + 1) @ 0.001 V ,
40 V ± (0.8% + 3) @ 0.01 V ,
400 V ± (0.8% + 3) @ 0.1 V ,
600 V ± (1% + 3) @ 1 V
AC voltage measurement:
4 V ± (1.2% + 5) @ 0.001 V ,
40 V ± (1.2% + 5) @ 0.01 V ,
400 V ± (1.2% + 5) @ 0.1 V ,
600 V ± (1.5% + 5) @ 1 V
DC current measurement:
40 A ± (2% + 3) @ 0.01 A ,
400 A ± (2% + 3) @ 0.1 A
AC current measurement:
40 A ± (2.5% + 5) @ 0.01 A ,
400 A ± (2.5% + 5) @ 0.1 A
Resistance measurement:
400 Ω ± (1.2% + 2) @ 0.1 Ω ,
4 kΩ ± (1% + 2) @ 0.001 kΩ ,
40 kΩ ± (1% + 2) @ 0.01 kΩ ,
400 kΩ ± (1% + 2) @ 0.1 kΩ ,
4 MΩ ± (1.2% + 3) @ 0.001 MΩ ,
40 MΩ ± (2% + 5) @ 0.01 MΩ
Capacitance measurement:
40 nF ± (4% + 25) @ 0.01 nF ,
400 nF ± (4% + 5) @ 0.1 nF ,
4 µF ± (4% + 5) @ 0.001 µF ,
40 µF ± (4% + 5) @ 0.01 µF ,
400 µF ± (4% + 5) @ 0.1 µF ,
4 mF ± (10%) @ 0.001 mF
40 mF @ 0.01 mF
Inductance measurement:
Frequency measurement:
10 Hz ... 1 MHz ± (0.1% + 4) @ 0.01 Hz ... 1 kHz ± (0.1% + 4)