UDP6720 Series Digital Control Power Supply
User’s Manual
20
It presents power output status and delayer time of user configuration
,
it’s convenient to view the data.
Protection setting
:
this function can set protection value of voltage, current and power, push rotary knob
select
“√”
to turn on protection function
;
Cycle index
:
It divide into maximum inf and 1-999. A cycle period is start form setup origin point to end point;
Count
:
It can set “001” - “048”, which is excute group from origin point to end point. Push rotary knob
to
adjusting parameter;
Origin point: It can adjust
“
000
”
-
“
047
”
, which is start from origin point to run. Push rotary knob
to adjusting
parameter (“origin point” value + “count” value
≤
048)
Mode: It divide into three mode stop, run and pasue, it can not set
;
Stop presents power supply is not output at the current
;
Run presents power supply is operating
;
Pause presents power supply is paused
;
Notice
:
In pause and run mode, interface can not be adjust; pause only shown when protection function is enabled.
Table setting
:
serial number of each group is corresponding to output status and delay time, push rotary knob
to set parameter
Mode
:
ON presents output function is enabled, OFF presents output function is disabled
Time
:
set the delay time of the main interface
;
,
: operating status at the current, push rotary knob
to switch mode
;
Save: save the setting parameter for powerdown function, push rotary knob
to save the current setting;
: clear parameter values in the table all to zero (voltage 00.00, current 00.00, time 00.00), push rotary
knob
to eliminate the setting parameter values in the table;
Notice: clear select function is eliminate the corresponding group of origin point to count.