background image

Quick Start Guide                                                                                                                                                                        MSO/UPO2000 Series

 

 

13 / 18

 

 

Instruments.uni-trend.com 

7.

 

Touch Screen 

MS series provides 8 inch super capacitive touch screen, multiple point touch control and gesture 
control. M has easily operating system with flexible and high sensitive touch screen features for 
great waveform display and excellent user experience. Touch control function includes tap, squeeze, drag 
and drawing rectangle.   

 

Hint: The menu displayed on the screen of the oscilloscope can use the touch control function.   

7.1    Tap 

Use one finger to slightly tap icon or word on the screen as shown in Figure 7. Tap can use for: 

 

Tap menu displayed on the screen and then to setup. 

 

Tap the function guide icon on the left corner of the screen to enable it.   

 

Tap to pop out numeric keypad to set parameter.   

 

Tap virtual keyboard to set label and file name. 

 

Tap message to pop out close button on the right corner to close it.   

 

Tap other window displayed on the screen to setup 

 

Figure 7 Touch Gesture 

7.2    Squeeze 

Squeeze two fingers together or separate. Squeeze gesture can zoom out or zoom in the waveform. If the 
waveform need to zoom out, squeeze two finger together and then slide away; If the waveform need to zoom 
out, separate two fingers and then squeeze two fingers together as shown in Figure 8. Squeeze gesture can 
use for:   

 

Adjusting horizontal time base of waveform on the horizontal direction.   

 

Adjusting vertical scale of waveform on the vertical direction. 

 

Figure 8 Squeeze Gesture 

Summary of Contents for MSO2000 Series

Page 1: ...Quick Start Guide MSO UPO2000 Series Digital Phosphor Oscilloscope...

Page 2: ...V1 00 Statement UNI T products are protected by patent rights in China and foreign countries including issued and pending patents UNI T reserves the rights to any product specification and pricing cha...

Page 3: ...n the Warning statement are not properly executed or observed Do not proceed to the next step until you fully understand and meet the conditions stated in the Warning statement Caution Caution indicat...

Page 4: ...from CAT III circuit or sockets more than 20 meters away from CAT IV circuit CAT III Primary circuit of large equipment directly connected to the distribution board and circuit between the distributi...

Page 5: ...s product before it is powered on AC power supply Please use the AC power supply specified for this device Please use the power cord approved by your country and confirm that the insulation layer is n...

Page 6: ...f UNI T for testing Any maintenance adjustment or parts replacement must be done by the relevant personnel of UNI T Cooling Do not block the ventilation holes at the side and back of this device Do no...

Page 7: ...Series digital phosphor oscilloscope includes four models Model Analog Channel Analog bandwidth LA AWG UPO2102 2 100MHz UPO2104 4 100MHz UPO2202 2 200MHz UPO2204 4 200MHz MSO2102 2 100MHz MSO2104 4 1...

Page 8: ...lease keep the packaging and notify both the transportation department and UNI T distributors UNI T will arrange maintenance or replacement 3 2 Before Use To perform a quick verification of the instru...

Page 9: ...and connect the probe to CH1 Make sure the probe s connector is properly connected with the oscilloscope Connect the probe s main clip and ground clip to the oscilloscope s compensating signal and gro...

Page 10: ...g waveform 14 Horizontal control HORIZONTAL 4 Jog dial knob 15 Analog channel input port 5 Function menu 16 Vertical control VERTICAL 6 Numeric keypad 17 Menu control soft key 7 Automatic control key...

Page 11: ...trend com 5 Rear Panel Figure 4 Rear Panel Table 2 Rear Panel No Description No Description 1 EXT Trig port 5 LAN 2 AUX Out and arbitrary waveform signal output 6 AC Power Input Socket 3 VIDEO Out 7 P...

Page 12: ...status identification 9 System time 2 Time base scale 10 USB DEVICE icon 3 Sampling rate storage depth 11 CH4 state icon 4 Waveform indicator 12 CH3 state icon 5 Waveform trigger position 13 CH2 stat...

Page 13: ...on the screen and then to setup Tap the function guide icon on the left corner of the screen to enable it Tap to pop out numeric keypad to set parameter Tap virtual keyboard to set label and file nam...

Page 14: ...ng Rectangle Open function guide and tap drawing rectangle icon to switch drawing rectangle mode Drag finger on the screentodrawing rectangle asshowninFigure 10 a 10 b Move fingeraway fromthescreen me...

Page 15: ...5 Touch Shortcut Operating Separate two fingers and meanwhile slide two fingers to one direction this gesture can quickly turn on off time measurement and voltage measurement cursor a Time measuremen...

Page 16: ...This symbolrepresentsthat numeric keypad on the front panel or touchto pop out numeric keyboard to input content This symbol represents that the current page can be flipped up or down Circle numbers...

Page 17: ...red voltage amplitude value is 10 times larger or smaller than the actual value Check the channel probe attenuation coefficient setting is consistent with the used probe attenuation rate 4 There is a...

Page 18: ...5 30pm UTC 8 Monday to Friday or via email Our email address is infosh uni trend com cn For product support outside mainland China please contact your local UNI T distributor or sales center Many UNI...