background image

9

MANUAL - SOLVENT RECYCLER  -  URS900SSW 

  

 

Revised 2011-07

Caution: Ensure that the bag material does not block the Vapor Outlet.

13) Inspect Lid Gasket, Remove and Replace if necessary as required

Inspect the Lid Gasket for shrinking, hardness and cuts. The Lid Gasket is a wear item as it is exposed to 
high temperature vapor during distillation. Damage to the lid gasket will cause it to leak.

To remove, open the Safety Cover and Tank Lid. Lift out the old gasket by hand and clean the cavity with 
a cloth. To Install, place the new gasket in the cavity, rub soapy water on the gasket to make insertion 
easier. Press the gasket fi rmly into the cavity all around.

Note: Keep a spare in stock. One extra is included with the unit.

Summary of Contents for URS900SSW

Page 1: ...USER MANUAL URS900SSW FOR RECYCLING WATER ONLY DO NOT USE TO RECYLE SOLVENT UNI RAM CORPORATION ONTARIO CANADA Revision 2011 07...

Page 2: ...S AND SPECIFICATIONS 4 SAFETY FEATURES 4 PREPARATION AND SETUP INCLUDED PARTS 5 LOCATION AND CONNECTION 5 6 DIRTY WATER MIXTURE 6 OPERATING PROCEDURES 7 9 THEORY OF OPERATION 10 TROUBLESHOOTING GUIDE...

Page 3: ...oggles gloves and mask Disconnect from the power source before performing maintenance This unit must be located at least 6 feet 1 8 m from all potential sources of ignition including electrical recept...

Page 4: ...roof construction and intrinsically safe electric circuitry Computer controlled with many built in safety programs including temperature control of all criti cal points including tank condenser and fa...

Page 5: ...feet from any potential source of ignition such as electrical receptacles switches pilot lights fixtures contacts and similar equipment To clarify the definition of an appropriate location contact you...

Page 6: ...nd cleaner residue The BP Boiling Point of the dirty mixture must be less than 200 C 392 F BP increases with greater contamination Recycle recently contaminated water only Standing mixtures can become...

Page 7: ...maximum is 200 C 392 F If the dirty mixture does not boil at the highest SET POINT of 200 C this unit will not be able to recycle the mixture To allow recycling at 200 C or less reduce the boiling poi...

Page 8: ...to loosen the bag from the bottom of the tank then lift the bag out while the bag is warm 10 Clean Distillation Tank and Lid Surface Distillation Tank Wipe inside the Tank with a cloth Remove any rema...

Page 9: ...et is a wear item as it is exposed to high temperature vapor during distillation Damage to the lid gasket will cause it to leak To remove open the Safety Cover and Tank Lid Lift out the old gasket by...

Page 10: ...ling condenser where purified clean water condenses out The waste material is left behind in the Liner Bag inside the distillation tank The dry waste is then disposed of according to local regula tion...

Page 11: ...an the path follow Service Pro cedure 2 and then recycle 3 gal of clean water Dirty water remains in Distil lation Tank after recycling Note 1 8 Gal 500 ml of recycled water is expected due to condens...

Page 12: ...ng erratically The computer may require re booting Disconnect the power supply for 30 sec onds Restore power and operate unit Residue puck in Tank is too wet 1 BAKE TIME is not long enough 1 Run SETUP...

Page 13: ...ondenser The Condenser is dirty or the Fan stopped for another reason see below Clean the Con denser When the Fan Motor has recovered 4 5 min this mes sage will disappear and normal operation will res...

Page 14: ...s out of the Liquid Outlet Tube the blockage has been cleared If not call for service 3 REPLACE FUSES Fuses are located on the Power Control Board inside the Motor Housing Disconnect power supply Remo...

Page 15: ...Lid and Bolt Assembly is carefully designed as a Safety Pressure Relief system to prevent a danger ous build up of pressure inside the closed tank Do not adjust the Spring Holding Nut by more than 2...

Page 16: ...0 3311 KEYPAD 900 3461 DIAPHRAGM PUMP UDP4TA DOOR HANDLE 2 SCREWS 120 318F 99 404S LID GASKET NEOPRENE 770 2150N LIQUID OUTLET TUBE 770 8131 LIQUID RECEIVING PAIL 750 710C TIMER WITH KNOB 115 200 K LI...

Page 17: ...ed with respect to this product s fitness for any purpose or the result to be obtained from its use This condition applies to the sale of all products and no representative or distributor of Uni ram C...

Reviews: