PROBLEM

CAUSE

ACTION STEPS

Unit is plugged in, power light is 
off, Display Panel is not working.

Power is not getting to 
the unit.

Reset breaker or replace fuse. If power  is 
still not getting to the unit, call a Qualifi ed 
Service Technician. Ensure that the unit is 
the only device on a circuit with suffi cient 
capacity.                                                                         

Unit is plugged in, power light is 
on, Display Panel is not working.

Power board or 
computer board not 
functioning.

Call Uni-ram Service 

Recycled liquid is not clear

1) The liquid is react-
ing chemically.

1) Run SETUP and lower the Termperature 
Set Point.  

2) The liquid fl ow path 
is dirty. One cause is 
overfi lling the distilla-
tion tank.

2) To clean the path, follow Service Pro-
cedure 2 and then recycle 3 gal of clean 
water.

Dirty water remains in Distil-
lation Tank after recycling                                                                                                                                        
 

Note:

 1/8 Gal (500 ml) of 

recycled water is expected due 
to condensation. 

1) Poor heat  transfer 
due to dirt and debris 
left in the tank.

1) Clean the tank, replace the Liner Bag, 
recycle with pure water to test. If suc-
cessfull, the problem is due to a dirty tank, 
debris left in the tank or the water is too 
contaminated. Adjust accordingly. Follow 
Operating Procedures closely. If the level 
of contamination is too high, recycle more 
often.

2) Boiling point of the 
dirty water mixture is 
above Temperature 
Set Point. 

2) Run SETUP, raise the Temperature Set 
Point and repeat the recycling operation.
The Temperature Set Point should be be-
tween 100°C and 200°C. If the boiing point 
of the mixture is above 200°C, the mixture 
cannot be recycled in this unit.

3) The Auto Shut Off 
system is shutting the 
unit off too soon.

3) Run SETUP and over-ride the auto 
SHUT-OFF. Select a time period long 
enough to fi nish recycling. The heater will 
stay on for this duration. Repeat the recy-
cling operation.

Liner Bag sticks

Turn unit on for 5 mininutes and lift out bag 
while it is still warm.

Summary of Contents for URS900SSW

Page 1: ...USER MANUAL URS900SSW FOR RECYCLING WATER ONLY DO NOT USE TO RECYLE SOLVENT UNI RAM CORPORATION ONTARIO CANADA Revision 2011 07...

Page 2: ...S AND SPECIFICATIONS 4 SAFETY FEATURES 4 PREPARATION AND SETUP INCLUDED PARTS 5 LOCATION AND CONNECTION 5 6 DIRTY WATER MIXTURE 6 OPERATING PROCEDURES 7 9 THEORY OF OPERATION 10 TROUBLESHOOTING GUIDE...

Page 3: ...oggles gloves and mask Disconnect from the power source before performing maintenance This unit must be located at least 6 feet 1 8 m from all potential sources of ignition including electrical recept...

Page 4: ...roof construction and intrinsically safe electric circuitry Computer controlled with many built in safety programs including temperature control of all criti cal points including tank condenser and fa...

Page 5: ...feet from any potential source of ignition such as electrical receptacles switches pilot lights fixtures contacts and similar equipment To clarify the definition of an appropriate location contact you...

Page 6: ...nd cleaner residue The BP Boiling Point of the dirty mixture must be less than 200 C 392 F BP increases with greater contamination Recycle recently contaminated water only Standing mixtures can become...

Page 7: ...maximum is 200 C 392 F If the dirty mixture does not boil at the highest SET POINT of 200 C this unit will not be able to recycle the mixture To allow recycling at 200 C or less reduce the boiling poi...

Page 8: ...to loosen the bag from the bottom of the tank then lift the bag out while the bag is warm 10 Clean Distillation Tank and Lid Surface Distillation Tank Wipe inside the Tank with a cloth Remove any rema...

Page 9: ...et is a wear item as it is exposed to high temperature vapor during distillation Damage to the lid gasket will cause it to leak To remove open the Safety Cover and Tank Lid Lift out the old gasket by...

Page 10: ...ling condenser where purified clean water condenses out The waste material is left behind in the Liner Bag inside the distillation tank The dry waste is then disposed of according to local regula tion...

Page 11: ...an the path follow Service Pro cedure 2 and then recycle 3 gal of clean water Dirty water remains in Distil lation Tank after recycling Note 1 8 Gal 500 ml of recycled water is expected due to condens...

Page 12: ...ng erratically The computer may require re booting Disconnect the power supply for 30 sec onds Restore power and operate unit Residue puck in Tank is too wet 1 BAKE TIME is not long enough 1 Run SETUP...

Page 13: ...ondenser The Condenser is dirty or the Fan stopped for another reason see below Clean the Con denser When the Fan Motor has recovered 4 5 min this mes sage will disappear and normal operation will res...

Page 14: ...s out of the Liquid Outlet Tube the blockage has been cleared If not call for service 3 REPLACE FUSES Fuses are located on the Power Control Board inside the Motor Housing Disconnect power supply Remo...

Page 15: ...Lid and Bolt Assembly is carefully designed as a Safety Pressure Relief system to prevent a danger ous build up of pressure inside the closed tank Do not adjust the Spring Holding Nut by more than 2...

Page 16: ...0 3311 KEYPAD 900 3461 DIAPHRAGM PUMP UDP4TA DOOR HANDLE 2 SCREWS 120 318F 99 404S LID GASKET NEOPRENE 770 2150N LIQUID OUTLET TUBE 770 8131 LIQUID RECEIVING PAIL 750 710C TIMER WITH KNOB 115 200 K LI...

Page 17: ...ed with respect to this product s fitness for any purpose or the result to be obtained from its use This condition applies to the sale of all products and no representative or distributor of Uni ram C...

Reviews: