4
MANUAL - UG2000 SERIES SPRAY GUN CLEANERS
REVISED 2019-03
LOCATION
Position the unit in a well-ventilated area away from sparks, heat and open flames, at least 6 " from the
back wall.
AIR SUPPLY
•
Connect a male air supply adapter (not supplied) into the female Air Inlet on the unit. The male air
supply adapter is 1/4" NPT.
• Connect the female air supply hose to the adapter. The air supply hose must be at least 3/8"
inside diameter.
The air supply pressure must be at least 85 PSI and the sup-
ply air must be free from contaminants such as water, dust, rust, tar and
grease. If the air supply is not clean and dry install a moisture filter. The
operation and longevity of the pump and other components depends on
clean dry supply air.
• To prevent damage to the Diaphragm Pump an internal Air Pressure Regulator has been
installed to limit the air pressure to 85 PSI. Do not install a second air pressure regulator or use a
pressure set below 85 PSI.
GROUNDING
•
Connect the green ground wire at the back of the unit to a ground in the building.
Note: The pump and metal tube that inserts into each pail are grounded.
SOLVENT SELECTION
The adhesion quality of automotive paint has dramatically improved in recent years. The choice of sol-
vent is critical. Only use good quality solvent that is formulated for your paint and intended for use with
automatic spray guns cleaners. DO NOT USE CHLORINATED SOLVENT.
PAIL SETUP
• Place a 5 gallon pail of commercial solvent inside the cabinet. Place the suction hose and drain
valve in the solvent pail.
• Open the drain valve (vertical position).
Ring Terminal
DRAIN VALVE IS OPEN
(HANDLE IN VERTICAL POSITION)
.
DRAIN VALVE IS CLOSED
(HANDLE IN HORIZONTAL POSITION).