Uni-P Pro 120X Dehumidifier

Installation, Operation & Service Instructions

Uni-P Pro 120X Dehumidifier

Installation, Operation & Service Instructions

 

 

Troubleshooting

 

 

Display is Blank

No Airflow

Error Code:E1

Error Code:E4

Error Code:LO

Error Code:HI

Tripped GFCI 

Outlet or Breaker

Cause

Solution

Poor Connection

Power Outage

Filter is dirty

Air Inlet or Outlet 

is Blocked

Humidity Sensor or 

Communication Error

Problem with Pump

Room Temperature 

is below 33

Room Temperature 

is above 105

Not a Dedicated Circuit

Defective GFCI Outlet

Dirt, Dust, or 

Moisture on Outlet

 

Lightning or Externa 

Electrical Surge

Possible Dehumidifier 

Issue

Verify that both ends of the 

cord are plugged in

Reset

 

power

Clean the Filter

Clean the

 

blockage

Check to ensure that the sensor wire 
is connected at both ends. if no issues 
are visible, the sensor may be faulty.

Verify that the pump is properly 
installed and functioning. If so, unplug 
the unit for two minutes,then restart.

Increase the room temperature so it is 
within operating range (above 33

). If 

error still displays, check sensor.

Decrease the room temperature so it is 
within operating range (below 105

).

If error stille displays, check the 
sensor

Identify all sources connected to outlet 
and confirm source of trip.If it is 
dehumidifier, contact technical 
support. If not, move dehumidifier to 
dedicated circuit for future use.

Replace Outlet

Clean or Replace Outlet as necessary

Reset or Replace Breaker/GFCI, as 
necessary

If none of above options work, contact 
technical support

Symptom

Pump Alarm- E4 Error Code

**

UNIT WILL NOT FUNCTION UNTIL ERROR CODE IS CLEARED

.

If E4 (pump alarm) is shown on the display, complete the following steps:

 

 

1. Reset the unit by unplugging the power cord and then reconnecting it.

2. Manually check to see if the pump is operational by pressing the drain button. Check

if the pump energizes and de-energizes properly. Additionally, check to see if any water

purged from the system.

3. If you haven’t cleaned the system recently, check the discharge line for an obstruction,

then clean as described in the Maintenance section.

4. Replace the hose and/or pump, if maintenance alone isn’t sufficient.

Spare Parts

Fan Components

External Components

Cables

Duct + Ventilation Accessories

N-100

N-101

N-102

N-1209

N-1206

N-1208

N-1207

Main Control Board

Display Board

RH/Temp. Sensor

Fan Motor

Complete Fan Assembly

Fan Capacitor

N-1210

N-1211

N-1205

N-1200

N-1201

N-1202

N-1203

N-125

Prefilter

MERV 8

HEPA

Carbon Filter

Foot adjustable

Display/Control

Inernal Components

N-120

N-121

N-122

Temp/RH Sensor Cable

Display Ribbon Cable

Ca

Т: 5 Port Internal Cable

N-1204

Supply Duict Collar 

Assembly

Compressor

Compressor Capacitor

Coil Assembly

Condensate Pump

Assembly

12

13

Summary of Contents for Uni-P Pro 120X

Page 1: ...Uni P Pro 120X Dehumdifier Installation Operation Service Instructions Add 2048 E Francis St Ontario CA 91761 Tel 888 994 0895 E mail sales unipdry com READ AND SAVE THESE INSTRUCTIONS...

Page 2: ...of purchase for your delmnidfier This information is necessary for seeking assistance in the future and can be found on the data label on the sde of the unit Model Number Serial Number Date of Number...

Page 3: ...needs a minimum of 12 clearance and the discharge requires a minimum of 36 clearance Unipdry dehumidifiers are only intended for operation when the unit is upright and level with the feet on the grou...

Page 4: ...open at the accessory float switch If an E4 error occurs immediately switch the wiring to N C normally closed on external switch You may need to unplug the unit to reset the error code 6 Auxillary Ter...

Page 5: ...being utilized The symbol on the display indicates the sensor on the dehumidifier is being utilized 4 Temperature The T button changes the temperature reading on your remote The remote comes from the...

Page 6: ...pump designed to pump water from the dehumidifier out to the desired drain The pump requires routine maintenance that is not covered by the warranty a Remove prefilter from inlet of machine b Vacuum o...

Page 7: ...o you have access to the pump 3 Remove the pump head from the reservoir by unscrewing the screw Wipe reservoir clean with a paper towel 4 Reassemble pump 5 Mix a 16 ounce solution of bleach 1 oz bleac...

Page 8: ...trip If it is dehumidifier contact technical support If not move dehumidifier to dedicated circuit for future use Replace Outlet Clean or Replace Outlet as necessary Reset or Replace Breaker GFCI as n...

Page 9: ...receive a Return Authorization RA number 3 Once an RA has been issued it is the customer s job to bring the unit to a certified repair center If this is not an option shipping will be arranged to bri...

Reviews: