4.3 Marking 

The type sign on the solenoid drive has the following information: 
 

 Fabricator 

  Valve type, nominal width, pressure and temperature indication, fitting position 

  Year of construction/ production no. 

  Product ID No.  

 

  Valve class and valve group acc.  

to DIN EN 16678, DIN 3394-1 

  No. of relevant location  

to 97/23/EC 

  Fluid group and test pressure PT 

to 97/23/EC 

  Solenoid drive type 

 Electr. 

performance 

 Voltage 

 Frequency 

 Protection 

type 

 

When using solenoid drives for x-protection zone 1 refer to information in the valid operating 
instructions. 
Refer also to section 10.0. 
 
 

5.0 Installation

 

5.1 

Warning of dangers during installation, operation and maintenance 

 

DANGER! 

Safe operation of the valve can only be guaranteed if it is installed, commissioned 
and maintained by qualified personnel (see point 2.3 “Qualified staff“) correctly and 
in observance of the warnings in this operating manual. Apart from that, the 
operation safety order and the qualified use of tools and protection equipment must 
be guaranteed. The operating instructions for the valve must be observed during all 
work on or with the valve. Failure to observe these instructions may result in injury 
or in damage to the valve or other installations. 

 
When the valve is used as a final sealing element, a safety precaution e.g. blanking disc, blind flange, 
etc., in accordance with the code of practice of the German Technical and Scientific Association for 
Gas and Water (DVGW) is recommended during all repair work. 

 
5.2 Installation 

Apart from the general installation guidelines, the following points should be observed: 
 
 

NOTICE!

 

 

Remove the flange covers. 

 

The inside of the valve and the pipeline must be free from foreign particles. 

 

Observe the installation position in relation to the flow direction, see markings 
on the valve. 

 

Centre gaskets between the flanges. 

 

The connecting flanges must be aligned. 

 

Ensure that none of the components is strained during installation. 

 

The valve must not be used as a fixed point; it is supported by the pipework 
system. 

 

Protect valves from soiling, particularly during construction work. 

 

Thermal expansion of the pipework must be equalized using compensators. 

 

NOTICE! 

Please observe the solenoid drive operating instructions (BTA). 

 

 

6.0 Operation 

 

 

 

Summary of Contents for EVF Series

Page 1: ...fety information for the use in explosion prone areas guideline 94 9 EC 3 0 Handling 3 1 Transport 3 2 Storage 3 3 Handling before mounting 4 0 Product Description 4 1 Function 4 2 Technical data 4 3...

Page 2: ...of these operating instructions suppose the qualification of the user according to paragraph 2 3 qualified staff The operating staff must be trained in accordance with the operating instructions The...

Page 3: ...TICE are used in this operating manual in case of notices concerning special dangers or for unusal information requiring a special marking DANGER means that in case of non observance there is danger t...

Page 4: ...a pipe screws by means of tooth disc Otherwise the connection to the ground must be implemented by other measures e g cable links Control valves electrical and electrical mechanical drives as well as...

Page 5: ...1 Fig in Fig 1 show the valve construction 4 1 Function On switching on of the solenoid drive 800 the solenoid core 207 is pulled against the upper part of housing 106 The pressure spring 503 is furth...

Page 6: ...ion safety order and the qualified use of tools and protection equipment must be guaranteed The operating instructions for the valve must be observed during all work on or with the valve Failure to ob...

Page 7: ...to the operating conditions UNI Ger te recommends an internal visual inspection once a year and an overhaul of the valve after 2 years or after the following number of switching cycles at the latest...

Page 8: ...ir work Observe section 6 4 when putting the valve back into operation 8 0 Dismantling of the Valve In addition to the general installation guidelines and the operation safety order the following poin...

Page 9: ...e all claims for damages against these companies will be voided 10 0 Explanations on Codes and Directives The Commission of the European Union has laid down common directives for the free trading of g...

Page 10: ...13 Version 12 2015 TM 3926 11 0 Drawing 11 1 Fig 1 40 EVF NH DN15 DN25 55 EVF NH DN15 DN25 100 400 200 950 902 1 912 402 3 219 1 943 2 243 219 2 402 1 402 2 406 906 503 1 227 943 1 941 1 948 1 910 1 9...

Page 11: ...er 110 1 Distanzst ck Spacer 120 1 Endschaltergeh use Limit switch housing 200 1 Ventilteller Valve disk 206 2 F hrungsring Guide ring 207 1 Magnetkern Solenoid core 210 5 Federbolzen Spring bolt 214...

Page 12: ...906 1 Scheibe Washer 908 1 Sicherungsblech Safety plate 910 1 4 Zylinderschraube Cylinder screw 910 2 4 Zylinderschraube Cylinder screw 912 1 Splint Split pin 941 x 1 Gewindestift Setscrew 943 x 1 Sp...

Page 13: ...ounting manual translation EVF _______________________________________________________________________________________________________ 220 100 112 07 Page 13 13 Version 12 2015 TM 3926 12 0 Declaratio...

Reviews: