background image

Installation Guide  

 

 

Unitronics 

 

Environmental Considerations 

 

 

 

 

Ventilation: 10mm (0.4”) of space is required between the device top/bottom edges 

and the enclosure’s walls. 

 

Do not install in areas with: excessive or conductive dust, corrosive or flammable 
gas, moisture or rain, excessive heat, regular impact shocks or excessive vibration, 

in accordance with the standards and limitations given in the product’s technical 

specification sheet. 

 

Do not place in water or let water leak onto the unit.  

 

Do not allow debris to fall inside the unit during installation. 

 

Install at maximum distance from high-voltage cables and power equipment. 

 

Kit Contents  

 

1 UAC-01EC2 module 

 

Diagram 

 

 

1  Snap-on clips 

Physically hold the module in place.  

2  USB Host port 

Maintenance port: update module’s firmware via USB flash 

drive 

3  IO/COM Bus-Left  

Left-side Connector 

4  Bus Connector Lock 

Slide the Bus Connector Lock to the left, to electrically connect 

the module to the CPU. 

5  IO/COM Bus-Right 

Right-Side Connector, shipped covered.  
Leave covered when not in use. 

Bus Connector Cover 

6  Functional Ground 

Terminal 

Connect to the system earth 

7  Ethernet port 

Supports EtherCAT fieldbus protocol 

8  EtherCAT LEDs 

Green LEDs 

9  Status LED 

Tricolor LED, Green/Red/Orange 

N

OTE

 

 

Refer to the module's specification sheet for LED indications. 

10  Module door 

Shipped covered with protective tape to prevent the door from 

being scratched. Remove tape during installation. 

    

   

Summary of Contents for UAC-01EC2

Page 1: ...cument Verify the Kit Contents Alert Symbols and General Restrictions When any of the following symbols appear read the associated information carefully Symbol Meaning Description Danger The identified danger causes physical and property damage Warning The identified danger could cause physical and property damage Caution Caution Use caution All examples and diagrams are intended to aid understand...

Page 2: ...ower equipment Kit Contents 1 UAC 01EC2 module Diagram 1 Snap on clips Physically hold the module in place 2 USB Host port Maintenance port update module s firmware via USB flash drive 3 IO COM Bus Left Left side Connector 4 Bus Connector Lock Slide the Bus Connector Lock to the left to electrically connect the module to the CPU 5 IO COM Bus Right Right Side Connector shipped covered Leave covered...

Page 3: ...e connecting or disconnecting any module or device Use proper precautions to prevent Electro Static Discharge ESD Installing the UAC 01EC2 Module 1 Check the unit to which you will connect the UAC 01EC2 module Verify that its Bus Connector is not covered If the UAC 01EC2 module is the last one in the configuration do not remove the cover of its IO COM Bus Right connector 2 Open the door of the UAC...

Page 4: ... before turning on the power supply Wiring Procedure Functional ground terminal Use a wire of minimum thickness of 14 AWG 2 mm2 terminate it with a ring or fork crimp terminal stud size 6 Tighten the screw enough to make sure the ring fork crimp terminal is not loose Wiring Guidelines In order to ensure that the device will operate properly and to avoid electromagnetic interference Use a metal cab...

Page 5: ...wing Ethernet Ethernet cable that meet at least the requirements of category 5 CAT5 with RJ45 connector USB Host Directly connect a USB flash drive with a Type A plug for updating firmware Using of cable to connect a device to the USB port is not allowed ...

Page 6: ...ited to any impliedwarranties of merchantability fitness for aparticular purpose or non infringement Unitronicsassumes no responsibility for errors or omissions in the information presented in this document In no event shallUnitronics be liable for any special incidental indirect orconsequential damages of anykind oranydamages whatsoever arising outof or in connection with theuse or performance of...