Operation

4. OPERATION CONTROL BOX

WATER SUPPLY (TAP)

CONCENTRATE

4.3. Filling the tank - producing pure water

The production of pure water works with the integrated RO- and DI-Filter. The produced  

water is stored in the tank and led with the two pumps to the left and/or right hose reel.  

So it is forwared into your water fed pole. Connect your water supply hose to the left  

connection. Connect the concentrate water drain hose to the right connection and lead it  

away from working area, so that it can drain. (Hose is not kinked, no adapter at end).

The lower control unit (RO FILLING) powers the RO booster pump. 

1.  To start filling the tank, simply press and hold the UP&DOWN buttons 

 , release buttons and you read 

FIL 

in the display. 

ATTENTION

: If you press the two keys too long, you get into the 

tdS 

mode. In this case return with the       

button. (see description of this mode below)

2.  The filling process starts until the float switch detects, that the tank is full.

3.  While the solenoid valve is on and the tank is filling the 

FIL 

message flashes.

4.  When the tank is filled, the diaphragm pump will stop and the battery tension will appear again in the  

RO-FILLING display. Display shows 

FUL

5.  To manually stop the tank filling, press and briefly hold the UP&DOWN buttons 

 again.  

The display will stop showing the 

FIL

 message.

Note 1: The cap of the tank has to be closed during filling process.  

 

      

Otherwise the float switch can not detect a full tank and continues filling!

Note 2:

 The solenoid valve will be turned off if the unit detects a low battery situation (below 10.5V).

4.4. Alarm/display messages

On the display different alarm messages can appear like described below:

ALARM

MESSAGE

CLARIFICATION

bAt

This message will start to flash when the battery tension is to low. 

If battery is below 10.5V the pump will be disabled to protect the battery (unless low battery 

cutoff is disabled). Connect the battery charger to charge the battery.

dE

Dead end detection, water flow is restricted (i.e. when the pole has been disconnected from the 

hose, you stand on the hose or air is in the system).  

Unroll the hose & check if these is not bend, reconnect the pole.

PS

Pressure switch activated or motor disconnected.

TDS HI

MAX. TDS value reached, replace the resin bags of the DI-filter

TDS StP

When the TDS value rises above the TDS cut-off setting the pump will be stopped.

The controller will display the left alarm message.

DISPLAY

MESSAGE

CLARIFICATION

FOB StP

Stop function activated of remote control

tP

Temperature indication

FIL

The RO- system is filling the tank with pure water

FUL

The tank is completely filled the with pure water

TDS Auto-Cut-Off

The unit monitors water purity in TDS (Total Dissolved Solids) in ppm (parts per million). 

For a good cleaning result this should be 10 ppm or below. The unit can be configured with a TDS cut-off if this value gets too high.  

By measuring the mineral content with the TDS- Meter you can determine the water quality.

The TDS-meter has a maximum reading of 50ppm.
• 

To monitor the water temperature (°C) press ENTER 

 until you read for example 

tP

17C

• 

Press ENTER 

 again to monitor TDS reading in ppm: Example: 

tdS

_20 

(a TDS higher than 50 is displayed with 

HI

)

• 

When the TDS value rises above the TDS cut-off setting, the pump will be stopped. The display will show: 

tdS

StP

• 

Note

: When the controller is first turned on, the TDS cut-off is disabled for app. 60 seconds to allow any dirty water to be pumped out

• 

Note: 

if you

 

push both the 

 buttons longer, you are entering the setting mode for the auto TDS value (

tdS

).

 

Do not change this value! Return to previous mode with the 

 key.

ENGLISH

Summary of Contents for HydroPower RO XXL

Page 1: ...T OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG MODE D EMPLOI ISTRUZIONI PER L USO INSTRUCCIONES DE MANEJO BEDIENINGSHANDLEIDING 1 Fully Integrated Trailer System with RO Filter tank for 650l pure water...

Page 2: ...osmosis membrane RO 18 6 2 5 Adding membrane preservative medium 18 6 2 6 Carbon water filter 18 6 2 7 Maintenance of the trailer 18 6 2 8 Maintenance at expense of technicians 19 6 3 Description dail...

Page 3: ...rrors Wrong usage of loose resin Overfill expansion of resin Parts of the system are opened incorrectly Replacing spare parts that are not included in the official Unger spare parts price list Perform...

Page 4: ...h electric components of the machine The areas on the machine marked with this symbol containing electric components and can never be opened or adapted by unauthorized person Toxic substances When the...

Page 5: ...rties Guarantee expires At change of owner At modifications repairing by a not recognised UNGER repairer Liability UNGER Germany GmbH as a manufacturer cannot become responsible for personal lesion da...

Page 6: ...ting the trailer so the hoses are locked could not unroll Uncouple the hoses again after transport from the RO connections when using the reels of the cleaner Spraying The water hose may not be aimed...

Page 7: ...return valve to prevent water flowing back into drink water line Trailer We recommend to transport the trailer without water a filled water tank could affect the riding behavior of the trailer Do not...

Page 8: ...d towards circumstances on their own water supplies under pressure or on a drinking water supply with a water barge When the machine is connected to the drinking water supply the existing regulations...

Page 9: ...trieve at the end of the manual 3 2 Visual perception HOSE REELS WATER TANK REVERSE OSMOSIS FILTER RO CARBON PRE FILTER ION EXCHANGE RESIN FILTER DI HydroPower DI DI24T CONTROL BOX nLite HydroPower DI...

Page 10: ...d materials are rejected by the membrane and carried away in the concentrate water stream The purified water contains only a fraction of these materials with TDS total dissolved solids a measure of th...

Page 11: ...our pressure causing cavitation degassing vapour lock and a loss in performance Inlet pressure must not exceed max 2 1 bar 30 psi Cover cap The cover cap could be opened closed easily by means of 1 lo...

Page 12: ...wrate for rinsing the surface Push the R button on the remote control RIN appears in the control box display and the diaphragm pump delivers more flow boost The rinsing value is by default always 30 h...

Page 13: ...CLARIFICATION bAt This message will start to flash when the battery tension is to low If battery is below 10 5V the pump will be disabled to protect the battery unless low battery cutoff is disabled C...

Page 14: ...ions for potential possibilities through coupling Caution lock the tow ball coupling correctly safely to your riding vehicle in case you want to use a removable coupling Pay attention for possible loo...

Page 15: ...e cable Extend support arm Technical check Mirror adjustment and clear visual from the car Check the cable guide of the trailer Perform lighting test Check ball joint lubrication Perform air pressure...

Page 16: ...pressure of the tires ca 4 bar and profile depth Couple the trailer and make sure that the shaft is connected firmly By pulling the shaft powerful up you can check if the coupling is put on firmly Tu...

Page 17: ...all sliding or jointed parts of the overrun device Check on possible wear of the wheel brakes bearings brake lining yearly 6 2 3 Ion exchange resin filter DI changing resin bags Instructions Shut off...

Page 18: ...no good filter results For this reason a special care agent must be filled in order to avoid this blocking 1 Disconnect the water supply if connected 2 Connect the concentrate hose so that excess wate...

Page 19: ...bolts of the trailer and if necessary fasten the wheel bolts Follow the good torque moments see also technical data 8 4 Repeat this always when a wheel is loosened for example if a tyre is changed tig...

Page 20: ...aks external damages and hair cracks If damaged or at leaks these must be immediately replaced 6 3 5 Electrical parts Check visible electric wiring and components on external visible damages If damage...

Page 21: ...chanism defective Push the locking pin to open and replace if necessary Insufficient braking of trailer Excessive friction losses or corrosion on the drawbar Damage caused by impact during manoeuvring...

Page 22: ...pump inlet outlet vlaves Leaks from pump head or switch For loose screws at switch or pump head Switch diagraphm ruptured or pinched For punctured diapgragm if fluid is present at bottom drain holes...

Page 23: ...water temperature 4 C Maximum water temperature See technical data Sufficient water supply at drinking water quality Directive 98 83 EG Depending on the composition of the raw water the treated water...

Page 24: ...11 Nm 25 Nm 36 Nm 43 Nm M 10 17 Nm 22 Nm 49 Nm 72 Nm 84 Nm M 12 29 Nm 39 Nm 85 Nm 125 Nm 145 Nm M 14 133 Nm 195 Nm 229 Nm M 16 206 Nm 302 Nm 354 Nm M 18 71 Nm 95 Nm 210 Nm 310 Nm 365 Nm M 20 138 Nm 18...

Page 25: ...V DC 210A Gel battery OPERATING PRESSURE max 10 bar 150 psi WATER FLOW RATE max 250l h MAX WATER IN TEMPERATURE 4 C WATER OUT TEMPERATURE 30 C NOISE LEVEL 75 dB DIMENSIONS LxWxH 3500x1750x1600 mm WEIG...

Page 26: ...3 28 83 188 4 8 4 PLACES 2 25 57 9 48 241 3 56 90 3 18 81 4 00 102 2 12 54 4 09 104 FILE 8030 813 239 REVISED 11 02 ISSUED 8 13 98 PumpAgents com buy pumps and parts online PumpAgents com Click here...

Page 27: ...S THIS GRAPH IS FOR USE AS A DESIGN GUIDE IT IS BASED ON RUNNING CONTINUOUSLY WITH AN AMBIENT TEMPERATURE OF 75o F IN STILL AIR THE THERMAL BREAKER WILL OPEN WHEN THE CASE TEMPERATURE REACHES 205 o F...

Page 28: ...hen be removed as ecologically sound as possible The possibilities those are open Exchange on a new machine Hand in at an waste treatment company Outside the E U you contact best the local government...

Page 29: ...in charger in the vehicle or machinery The charger can be with fixed connection to the battery or with conventional connectors Position the charger in such a way that the air supply will not be obstr...

Page 30: ...in Cable 1 6M full length 3 x 1 0 mm2 Protection IP 65 General Protected against wrong polarity and short circuit CE and Euronorms In accordance with the Low Voltage Directive 72 245 EEC and 2004 104...

Page 31: ...www ungerglobal com 31 HydroPower RO XXL Notes ENGLISH...

Page 32: ...rglobal com Unger UK Ltd F1 Deansgate 62 70 Tettenhall Road Wolverhampton WV1 4TH UNITED KINGDOM Fon 44 0 1902 306 633 Fax 44 0 1902 306 644 ungeruk ungerglobal com Unger Enterprises LLC 425 Asylum St...

Reviews: