HydroPower® RO
S
System overview
4
Preparing for use
4.1
Construction of the HydroPower RO
S
4.2
Interfaces
On the front is 1 connection for attaching the hose for the water fed
pole and 1 connection for the water supply. These are standard hose
connections.
Make sure that water cannot flow back into the tap water line, e.g.
through a backflow prevention device.
The water outlet for the concentrate is located at the back. Pour the
concentrate down the drain unsing the enclosed concentrate hose.
1 Manometer
2 TDS-Meter
3 Switch WORK/RO FLUSH
4 Switch TAP BOOST / OFF / PURE
5 Water inlet
6 Water outlet
7 Water meter
8 Carbon/sediment combi pre-filter
9 Membrane
10 DI resin filter
11 Pump ventilation slot
12 Pump Control
13 Power cord
14 Concentrate output
(connection concentrate hose)
The
manometer
shows the water pressure behind the pump. Ensure that
the water inlet pressure is at least 1 bar. The optimum is 4 bar, maximum
should not exceed 6 bar. The pump increases the pressure by approx. 4 bar.
Accordingly, the pressure in operation should not exceed 10 bar.
ENGLISH
The
TDS meter
shows the water quality at water outlet for the Pure and the
Boost Mode.
PURE: TDS metre shows the value of the filtered water after RO Membrane
and DI resin. It should ideally show a value of 0. At the latest when it shows
10, the resin should be replaced.
TAP BOOST: TDS metre shows the value of the tap water.
The
water meter
measures the water flow at the inlet. This is particularly
important for the combination pre-filter, as it must be replaced after approx.
30,000l.