background image

③ Start Test

9

                   ●

10

                   ●

● When radar alarm output is set and saved, power on the radar, and connect 
the

 

siren to radar, even if there is no PC server connection, the radar still works

to trigger

 

the siren for intrusion protection.

Please  correctly  connect 

SMWR21A-P

  network  cable  with  PC,  and  connect 

12V  DC,

 

then

 

bootup  NSM  Tools  Management  System  User  Manual 

for  IP configuration

 

details(Help). 

 Strobe Siren Connection

Strobe siren signal wires are to connect to radar alarm signal output, as the 

diagram 3-4:
Note:

 

Radar alarm output is I/O relay type, please choose the right model & type 

strobe

 

siren.

3.3

Fig.3-4

Millimeter Wave Radar

Millimeter Wave Radar

Note:
● Output channel 1=Alarm Ou 1、Output channel 2=Alarm Out2、

Output channel 3=Alarm Out1、Output channel 4=Alarm Out2.

● Only in rusion inside the drawn alarm zone can trigger the strobe siren.
● Only when alarm zone is set up, the strobe siren will work, if no alarm zone is set

Malfunction

Normal power supply 
but fail to detect target.

Radar can’t connect 
when power on

No any response after 
power on

No target in the 
detection area but there 
is target signal output

No alarm output to 
strobe siren

  

Solution

  Refer to the above radar LED indicator light status to check the radar working 

    

status. If it is abnormal, please report the problem description and LED status 

  

to the engineer of the manufacturer;

    Check if the buzzer gives off the sound “di” four times after power on. If not, 

  

please check if the polarity of radar power cable is correctly connected to 12V 

.C

D

DC. The rada

 

orking current 

SMWR21A-P

 

is about 650mA.

  Make sure the radar is normally powered on and the radar is normally 

activated, see above“No any response after power on”; 

  Use THE NSM Tools tool to search the radar to find out if the device IP has 

    

been modified;
Check if the PC local add radar IP segment;
PC terminal ping radar IP, check whether can ping radar.
Please refer to chapter2.3 and check if radar installation direction is correct.

  Use designated FMCW simulator to check if radar output is normal.

Please check if the radar installation position aims at the target area, which 
may cause the radar to be disturbed by the surrounding objects:
Confirm if there is any vibration of pole where radar installed and check if GND 
is normal.

Check if the alarm zone is drawn. ( When intrusion into the zone can trigger 
alarming, target outside the zone can not trigger siren alarming.)
Check if the radar can cover the alarm zone in distance range. 

● 

   

If two points above are correct, then use multi-functional meter to gauge the 
two I/O signal output wires, by checking if it will sound alarming on the 
buzzer mode.
When there is intrusion target in pre-set alarm zone, the radar is in well 
condition if the meter sounds alarming.  Then check the siren if it works or its 
type not matching. 
When  there is intrusion target in pre-set alarm zone, the radar could has 
issue if the meter does not sound any alarming.

● 

 

●  


●  

●  

● 

●  


● 


Table 4-1

FAQ & Solutions

Note:

● Please make sure the installer conform to the radar instal ation instruction.

4.

3.5  Strobe Siren 

       Please refer to siren operation manual. 

Summary of Contents for SMWR21A-P

Page 1: ...15 Millimeter Wave Radar User Manual ...

Page 2: ...iring of the building Prevent the power cable from being trampled or pressed especially the plug power socket and the device adaptor We assumenoliability or responsibility for all the firesor electrical shock caused by improper handling or installation Environment Hard ground is the best choice for detection area such as cement ground As forthe groundcovered withvegetation make sure the height of ...

Page 3: ...cloth to clean the device If the dust is difficult to be removed please wipe it away with a clean cloth wetted slightly by the mild detergent and then use dry cloth to clean the device Do not use volatile solvents like alcohol benzene thinner or abrasive detergent which will damage the surface coating or reduce the working perfor mance of the device Warnings Usethestandardprovidedbymanufacturerand...

Page 4: ...5V AC Full load el ectrical durability 100000 times If the tolerance sen sibilityLoad please keep the current allowance in place High and low level input It s the optocoupler drive end which requires driving Current 0 3 20 mA Related parameters desc ription light emitting dio des leds pressuredrop1 2V radar board built in 200 Ω current limiting resistor Red green LED statue Indicator light show th...

Page 5: ... shown in Fig 2 4 Generally the radar antenna plane shall be installed vertical to alert area in order to guarantee the precision of the radar besides it needs to be installed at a certain height which normally is recommended to be 1 3m Fig 2 3 Fig 2 4 Generally the radar front plane please install the device upright Radar Radar Detection Area Radar Alert Area Fig 2 5 3m 90 2 2 Dimension Note The ...

Page 6: ...to the wall or fence is best above The radar installation height is recommended to be 2 meters which can be adjusted according to actual needs but not to exceed 6m Radar detection blind area is different for different installation heights generally radar installation height no more than 3m or 4m is recommended If the radar is installed directly above the fence it is recommended that the radar inst...

Page 7: ...r operation Please contact supplier customer service for CMS SETUP PC test software and its user manual Installation and configuration of the software shall subject to the user manual Test steps as follows Test equipment required is shown as table 3 1 Keep the convex groove outward and install the rubber ring into the network port with the smaller hole outward and install the fixing rubber ring in...

Page 8: ...themanufacturer Checkifthebuzzergivesoffthesound di fourtimesafterpoweron Ifnot pleasecheckifthepolarityofradarpowercableiscorrectlyconnectedto12V C D DC Therada orkingcurrentSMWR21A Pisabout650mA Makesuretheradarisnormallypoweredonandtheradarisnormally activated seeabove Noanyresponseafterpoweron UseTHENSMToolstooltosearchtheradartofindoutifthedeviceIPhas beenmodified CheckifthePClocaladdradarIPs...

Page 9: ...of of this warranty certificate Replacement due to quality problems within 7 days since the purchase date is available The warranty period is 1 years Priority to access for new product information or promotions opportunities Product failure resulted from following conditions is not covered by the warranty Can not show valid warranty certificate and purchasing invoice or payment receipt Product fai...