background image

CFIP Lumina Series 

Full Outdoor Unit 

Technical Description & Configuration Guide

 

Product code: I0DGETD1

 

 SAF Tehnika JSC 2013

Содержание Lumina Series

Страница 1: ...CFIP Lumina Series Full Outdoor Unit Technical Description Configuration Guide Product code I0DGETD1 SAF Tehnika JSC 2013 ...

Страница 2: ...a FODU to antenna 23 2 4 Resetting the CFIP Lumina 25 2 5 Web Interface 25 2 5 1 ODC Port 25 2 5 2 Ethernet Management Connection Configuration 25 2 5 3 Connecting to Web Interface 27 2 5 4 Interface Description 29 2 5 5 Command Execution 29 2 5 6 Initial Configuration with Web GUI 30 2 6 Command Prompt Interface 34 2 6 1 RS 232 Serial Management Port 35 2 6 2 Telnet connection 37 2 6 3 Initial Co...

Страница 3: ...s Tables 77 5 1 3 Alarm Status Window 79 5 1 4 Alarm Log 79 5 1 5 Alarm and Alarm Threshold Configuration 80 5 1 6 Alarm Management Commands 82 5 2 Performance Management 83 5 2 1 Performance Management Data Collection 83 5 2 2 Performance Values 84 Threshold Seconds TS 84 Tide Mark TM 84 5 2 3 Performance Management in Web GUI 84 5 2 4 Constellation Diagram 87 5 2 5 Adaptive Equalizer 89 5 2 6 Pe...

Страница 4: ...d to Router In Case one IP address of Remote Units is Known 113 10 RSSI Port 114 11 Pinouts 115 11 1 ODC connector 115 11 2 RJ 45 connector 115 11 3 Twin BNC Connector 115 11 4 DC power connector 116 12 Available accessories 117 12 1 AC DC power adapters 119 12 2 Other Available Accessories 119 13 List of Abbreviations 121 14 SAF Tehnika JSC Contacts 123 The CFIP Lumina Series Full Outdoor Unit Te...

Страница 5: ...roduct family is the new next generation product line which is targeting on growing demands for data transmission over microwave radio As a result the primary traffic interface for CFIP Lumina radio is Gigabit Ethernet As CFIP is capable of providing bit rate of up to 366Mbps it is a great addition to SAF portfolio CFIP Lumina radio and modem performance allows achieving perfect system capacity by...

Страница 6: ...igure 1 1 CFIP Lumina Full Outdoor Unit 1 2 3 Interfaces Management CFIP Lumina unit provides 4 or 5 connectors depending on model and a grounding screw User and NMS traffic is carried over FO cable or Cat 5e cable depending on the model Ethernet traffic supports QoS and 4 priority queues essential for ACM use User and NMS traffic could be treated as a single data stream or separated by tagging wi...

Страница 7: ...ctors Figure 1 4 Hybrid CFIP Lumina FODU connectors RSSI port Twin BNC ODC port LAN1 ODC port LAN2 DC connector RJ 45 port LAN4 RJ 45 port LAN3 RJ 45 port LAN3 ODC port LAN2 The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide Rev 1 10 SAF Tehnika JSC 2013 7 ...

Страница 8: ...bility Very high flexibility allows configuring the system to various channel bandwidths modulation schemes and capacity settings 1 4 Application Examples 1 4 1 Carrier Gigabit Ethernet Trunk Distribution with CFIP Lumina Superb for extending Fiber Optics network over high capacity radio Ideal for crossing mountains and interconnecting Gigabit Ethernet networks Designed for building Ethernet backh...

Страница 9: ...t Chain Figure 1 7 CFIP Lumina East West chain 1 4 4 CFIP Lumina ring topology Utilization of STP protocol allows CFIP Lumina operation in ring topology The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide Rev 1 10 SAF Tehnika JSC 2013 9 ...

Страница 10: ...s Flange N type UBR 84 UBR 100 UBR 140 Circular 13mm UBR 220 Circular 10mm UBR 260 UBR 320 Ethernet Optical 1 or 2 ODC ports Electrical 1 or 2 RJ 45 Hybrid 1 ODC and 1 RJ 45 DC power connector 2 pin waterproof circular RSL port RSSI BNC connector Output voltage vs RSL 0 to 1 4V vs 90 to 20dBm Serial port for configuration RS 232 Twin BNC connector III Management features Management port Ethernet V...

Страница 11: ...weighted configurable ratio Spanning Tree Protocol 802 1D 2004 RSTP 802 1Q 2005 MSTP III Mechanical Electrical Stationary use Ref ETSI EN 300 019 2 4 class 4 1E non weather protected locations Temperature Range 33 C to 55 C Dimensions HxWxD mm weight kg 288x288x80 3 9 Built in DC port surge protection Conforms to ETSI EN 301 489 1 EN 61000 4 5 IEC 61000 4 5 Input DC voltage 40 5V to 57V DC conform...

Страница 12: ...5 83 5 82 5 82 5 84 5 78 5 74 32QAM Strong 81 80 80 79 5 80 5 80 5 80 80 5 79 5 79 5 81 5 75 5 95 64QAM Strong 78 5 77 77 76 5 77 5 77 5 77 78 77 77 79 73 123 128QAM Strong 75 5 74 74 73 5 74 5 74 5 74 75 74 74 76 70 147 256QAM Strong 72 70 5 70 5 70 5 71 71 70 5 71 5 70 5 70 5 72 5 66 5 172 Weak 69 68 5 65 5 65 5 67 66 5 66 5 69 67 5 67 5 70 63 5 184 50 4QAM Strong 87 5 86 5 87 86 5 87 5 87 87 87...

Страница 13: ... 83 5 77 98 32QAM Strong 80 78 5 79 78 5 79 5 79 5 79 79 5 78 5 78 5 80 5 74 5 127 64QAM Strong 77 76 75 5 75 5 76 5 76 76 77 75 5 75 5 78 71 5 164 128QAM Strong 74 73 72 5 72 5 73 5 73 72 5 73 5 72 5 72 5 74 5 68 5 196 256QAM Strong 70 5 69 5 69 68 5 69 5 69 5 69 70 5 69 69 71 65 229 Weak 68 67 64 5 64 5 65 5 65 65 67 5 66 5 66 5 68 5 62 5 245 56 4QAM Strong 87 85 5 86 85 5 87 86 5 86 87 85 5 85 ...

Страница 14: ... fibre optics cable using default single mode 1310nm SFP module is up to 10 kilometres 6 2 miles SAF Tehnika JSC can provide pigtail cable with ODC LC connectors and length of 3 10 25 or 50 meters 10 33 82 164 ft Figure 1 9 CFIP Lumina ODC LC cable DC power cable CFIP Lumina power supply voltage must be between 40 5 57 V DC 2 wire outdoor cable with dedicated 2 pin LTW DC connector assembly is nee...

Страница 15: ...e antenna alignment a coaxial cable with BNC connector on one end and appropriate termination on other end can be used see example in Figure 1 4 Figure 1 11 Cable for connecting the voltmeter to the CFIP Lumina RSSI port 1 7 AC DC power adapter requirements Table below helps choosing the most appropriate power adapter from SAF Tehnika accessories list for standard and high power CFIP Lumina radios...

Страница 16: ...nm SM transceiver On demand CFIP Lumina at factory premises can be equipped with alternative SFP modules Specifications of available SFP modules CFIP Lumina high power Band GHz Max power consumption W Min recommended PSU power W 6 40 60 7 33 60 8 33 60 10 40 60 11 40 60 13 34 60 15 34 60 17 34 60 18 32 60 23 34 60 24 29 60 26 32 60 38 37 60 Band GHz Max power consumption W Min recommended PSU powe...

Страница 17: ...ustomer premises and appropriately sealing the weld 2 As Lumina FODU DC in port has a built in surge arrestor solution SAF only recommends to use surge arrestor at the DC source end of the cable Figure 1 13 Optical CFIP Lumina site 1 ODC LC cable 2 Surge arrestor on power cable 1 10 CFIP Lumina with RJ 45 Gigabit Ethernet Port Electrical Gigabit interface is vulnerable to overvoltage jumps thus el...

Страница 18: ...mina site 1 11 Labelling The label can be found on the front side of the unit The label contains the following information see samples in the picture below The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide Rev 1 10 SAF Tehnika JSC 2013 ...

Страница 19: ...8 GHz of the Unit G designates standard power CFIP Lumina with 20 56 MHz channel bandwidth support S high power CFIP Lumina with 20 56 MHz channel bandwidth support N standard power CFIP Lumina with 14 56 MHz channel bandwidth support H high power CFIP Lumina with 14 56 MHz channel bandwidth support H designates Gigabit Ethernet 1x Electrical E 2x electrical O 2x optical SM M 2x optical MM L 1x op...

Страница 20: ...al frequency of the first 20 MHz channel to the central frequency of the last 20 MHz channel see the Figure below Figure 1 17 Frequency range of low and high side CFIP Lumina 18 GHz FODUs The Figure explains Tx frequency range of low and high side CFIP Lumina 18 GHz radios The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide Rev 1 10 SAF Tehnika JSC 2013 ...

Страница 21: ...ASCII console connected to the serial port It is highly recommended to perform initial configuration in the lab using testing suite or bouncing signal from the ceiling 2 1 Assembling CFIP Lumina weatherproof DC Connector Assembling of weatherproof DC connector does not require any additional tools all below mentioned operations can be done manually 1 2 3 4 5 6 The CFIP Lumina Series Full Outdoor U...

Страница 22: ...e Ethernet cable Cat5e or better to CFIP Lumina FODU Instead of running two separate cables for power and Ethernet this solution allows to run just one cable from inside equipment to the radio outside The non IEEE PoE injector and splitter both have a built in lightning and surge protection preventing transient over voltages from damaging CFIP Lumina radio and user s indoor equipment Polarity layo...

Страница 23: ...n and 4 side lockings for attachment Lockings should be tightened in diagonal sequence Licensed frequency bands 6 38 GHz Pair radios in licensed frequency bands 6 38 GHz use same polarization for Tx Rx channels on both ends of the link either horizontal or vertical Gigabit Ethernet DC Gigabit Ethernet DC DC Gigabit Ethernet The CFIP Lumina Series Full Outdoor Unit Technical Description and Configu...

Страница 24: ...Pair radios in unlicensed frequency bands 17 24 GHz use both polarizations simultaneously via circular flange radios on opposite side of the link should be installed with 90 degree offset Example of 24GHz antenna and FODU mating on local and remote sides of the link and appropriate indication in Web GUI Lockings should be positioned in way it is shown on picture The CFIP Lumina Series Full Outdoor...

Страница 25: ...dem and CPU of the management controller Resets all management counters 2 5 Web Interface This section describes operation of Web interface 2 5 1 ODC Port ODC port is used to connect the CFIP Lumina to a PC or Ethernet network for Web SNMP and Telnet management The length of single mode FO cable can be up to 10 kilometres 6 2 miles 2 5 2 Ethernet Management Connection Configuration Before you proc...

Страница 26: ...t Protocol TCP IP from the list in the dialog box and then click on Properties Figure 2 6 4 In the dialog box enter the following values so that your PC is in the same subnet as default CFIP Lumina addresses The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide Rev 1 10 SAF Tehnika JSC 2013 ...

Страница 27: ...selection open it and enter address of the FODU Figure 2 8 It is important to know the Side parameter of the FODU to which you want to connect whether the factory settings are loaded in FODU If Low Side IP 192 168 205 10 If High Side IP 192 168 205 11 Figure 2 8 CFIP Lumina IP address The default username and password for Web access are username admin password changeme The CFIP Lumina Series Full ...

Страница 28: ... configured values are not the same for Local and Remote or there is a problem with parameter value the appropriate cell will be highlighted in red colour Figure 2 9 Web Interface main window Note that CFIP Lumina 17 and 24 GHz unlicensed utilize both polarizations and radios must be installed with 90 degrees offset regarding remote side This as well as position of cables can be verified in Main s...

Страница 29: ...dicate that specific parameters do not comply with the norms of normal operation For example value is out of range local value is not equal to the remote value and vice versa only in some places no value data N D If the entry is highlighted in yellow this means warning condition If the value place reads N D this means No Data If the value place reads N A this means Not Available Figure 2 10 Web In...

Страница 30: ...ccessful configuration used Rollback will activate only if you lose connection to WEB interface of CFIP Lumina after configuration changes applied and reverting process will take approx 3 minutes After parameter value editing when the focus from this object is removed this parameter value edit box may be highlighted in red meaning that entered value is not valid If Execute configuration or Execute...

Страница 31: ...naging at the moment you can try both default IP addresses Currently supported browsers you can use are Internet Explorer Mozilla Firefox Apple Safari Opera and Google Chrome Figure 2 13 Supported browsers Internet Explorer Mozilla Firefox Apple Safari Opera and Google Chrome When you are connected to the CFIP Lumina you will see the window similar to the one shown in Figure 2 9 CFIP Lumina must b...

Страница 32: ... specify preferable system name passwords for guest and admin accounts The next time you will try to access the Web GUI management you will be asked to enter the user name guest or admin and user password By default system name is SAF Default password for admin account is changeme guest account is disabled by default It is highly recommended to name the system after its geographical location The C...

Страница 33: ...M downshifts or upshifts modulations and Tx frequency range depends on bandwidth chosen besides the modem and radio data status is being shown Enabling Fixed Tx power will not increase Tx power when ACM downshifts modulation order These configuration parameters will determine overall link capacity Figure 2 17 STEP 3 Defining modem bandwidth modulation Tx power and frequency For CFIP Lumina 17 and ...

Страница 34: ... is up 2 6 Command Prompt Interface CFIP equipment can be monitored and configured by using command interface described in this chapter This process is performed by connecting to Telnet terminal via Ethernet port Telnet management supports only one client Command line management interface offers wider configuration and monitoring functionality The available commands for Telnet management are found...

Страница 35: ...e PC to the RS232 serial port by means of straight through or modem serial cable null cable 2 Run Hyper Terminal program 3 Make a New connection and enter connection name Figure 2 20 Subcommands and keywords are in regular font Arguments in square brackets are optional but required arguments are in angle brackets Alternative keywords are grouped in braces and separated by vertical bars The purpose...

Страница 36: ...5 Set port settings bits per second 19200 data bits 8 parity none stop bits 1 data flow control none Figure 2 22 6 Press OK The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide Rev 1 10 SAF Tehnika JSC 2013 ...

Страница 37: ... management connection Please refer to Chapter 2 2 2 for Ethernet management port connection details When you are ready to connect to Telnet interface please follow these steps 1 Go to Start Run 2 Type in telnet ip_addr where ip_addr is IP address of the CFIP Lumina you want to connect to refer to CFIP Lumina label explanation in Chapter 1 8 The CFIP Lumina Series Full Outdoor Unit Technical Descr...

Страница 38: ... 1 Check the system settings with command status 2 Configuration required parameters Before you set the parameters listed below you must know what frequency and bandwidth you are allowed to use and at what power you are allowed to transmit In the table below please see interdependence between antenna used and allowed CFIP Lumina 17 and 24 GHz Tx output power range Antenna size gain 17 GHz 24 GHz 3...

Страница 39: ...ystem name name Default name is SAF IP address with the command net ip addr addr if it is necessary IP mask with the command net ip mask mask if it is necessary IP default gateway with the command net ip gw gw if it is necessary 3 Save settings with the command cfg write restarting with the command system reset 4 Check the settings made modem and radio status with the commands status modem status ...

Страница 40: ... understanding of Main status page explanation of each parameter is provided below Figure 3 1 Main status page 1 Shows the name of CFIP Lumina you are connected to its IP address serial number and uptime since the last restart If uptime is displayed in red the connection to Web server was lost 2 Shows firmware version of CFIP Lumina you are connected to 3 Logout button allows ending current Web GU...

Страница 41: ...ommand line radio status 15 Rx frequency shows the receiving frequency command line radio status 16 Configuration file shows which configuration the modem is currently using It should match on both sides of the link command line modem configuration 17 Bandwidth shows width of currently utilized bandwidth in MHz command line modem status or status 18 Modulation shows modulation mode set command lin...

Страница 42: ...on of connectors and cables command line diagnostics 36 Name serial number shows system name and serial number command line system name and system inventory 37 License remaining time shows amount of time in seconds remaining for active time limited license if applicable in case of no license N A is being shown in case of unlimited time license Unlimited is being shown command line license status 3...

Страница 43: ...ilable in Alarm configuration page where it is possible to disable alarm if necessary For further details please refer to Chapter 5 1 3 3 Ethernet aggr prot status Ethernet aggregation protection status page shows summary of current 2 0 1 0 aggregation protection status if such is enabled In case of no configuration Aggregation protection is disabled will be shown 1 Clear max N D time clear maximu...

Страница 44: ...on Chapter 4 2 5 3 Download alarm log file allows saving alarm log file in separate txt file on your hard disk drive Same functionality is available in Performance Alarm log Alarm event log file Chapter 5 1 4 4 Download pm log 1 minute interval allows saving performance log file for 1 minute intervals in separate txt file on your hard disk drive Same functionality is available in Performance Perfo...

Страница 45: ...ntry will be disabled if ACM or and ATPC is enabled Please disable both in order to change the value command line radio txpower power dBm 4 Tx power mode Tx power will remain constant during ACM operation modulation downshifting upshifting if fixed mode is selected otherwise variable Tx power will be applied command line radio fixedpower disable enable or 0 1 5 Tx frequency allows you to enter pre...

Страница 46: ...correction limit allows defining the amount of dB ATPC will be able to correct regarding initial Tx power value command line atpc limit tx power correction limit 5 Remote device status shows if management CPU was able to read data from remote management CPU 6 Rx remote level maximum 60 20 dBm allows defining the maximum Rx level ATPC Tx power correction will be performed only in case of exceeding ...

Страница 47: ...CM profile Different algorithms can be implemented to achieve maximal spectral efficiency or minimal transmitted power using both features in combination One implementation could target maximal spectral efficacy by trying to reach the highest ACM profile while the other is willing to compromise on some of the spectral efficiency enabling CCI and ACI reduction In any chosen algorithm ATPC reduces t...

Страница 48: ...nd remote side CFIP Lumina link Adaptive code and modulation ACM technology allows operators to achieve high capacity data transmission over microwave links and improve the link utilization This reduces both operational and capital expenditures for maintaining high capacity links ACM can maintain the highest link spectral efficiency possible at any given time in any link condition In traditional v...

Страница 49: ...se of degradation in the link performance the new ACM profile will include lower modulation decreasing the link bitrate The ACM switching rate is measured in dB s and is a key feature of ACM systems In general the higher the switching rate the better the system s immunity to rapid Radial MSE changes When the switching is being executed the payload rate is being modified to fit the aggregated data ...

Страница 50: ...ynchronous TDM traffic to packet IP based traffic The FEC mode Weak or Strong allows increasing overall capacity of the link in terms of deteriorating RSL sensitivity threshold For more details refer to table in Section 1 6 4 1 4 Loopback Configuration Loopback tests are accessible using local or remote management methods For safety purposes all loopbacks local and remote can be set on a fixed tim...

Страница 51: ...wise it says Ok Radio frequency loopback In order to check performance of CFIP Lumina 17 and 24 GHz radio frequency loopback should be used a In Tools Command line enter command radio txpower 10 in order to set transmit output power to 10 dBm b In Tools Command line enter command loopback rf time_in_second where time_in_seconds should be substituted by sufficient time of loopback operation c Obser...

Страница 52: ... modem ipremote on off Allows enabling manual remote IP specifying modem ipremote off By default remote IP is being obtained automatically modem ipremote on modem counters show clear Shows modem performance counters according to G 826 standard radio factory max Resets radio settings to factory defaults By default Tx power will be turned off max option will switch Tx power to the maximum value afte...

Страница 53: ... the user name cannot exceed 30 symbols By default password for admin account is changeme Admin account has full control of the CFIP configuration process 3 Hide password s Hides typed in password This option unchecked will display typed in password in plaintext 4 Pressing Execute configuration applies changes made to the corresponding section only for the local side CFIP Lumina If Rollback on is ...

Страница 54: ...or laptop from which you are connected to the Web interface command line system time yyyy mm dd hh mm ss 3 Pressing Execute configuration applies changes made to the corresponding section only for the local side CFIP Lumina If Rollback on is selected configuration will be reverted in case of erroneous configuration changes applied 4 Write to config file saves to configuration file all the changes ...

Страница 55: ...rmation is gathered and displayed Additional system commands in Telnet serial interface Command Description System status Displays the name of the device and its uptime System inventory show Displays the CFIP Lumina product code serial number and additional information System aliases list all basic off add remove clear list shows the alias list and whether the aliases are going to be used The user...

Страница 56: ...ified command line net ip gw gw 4 Ethernet MAC address shows the MAC address of CFIP Lumina you are currently connected to command line net mac 5 Remote IP Address shows IP address of remote far end CFIP Lumina to ensure communication between link sides command line net ip remaddr remaddr 6 Pressing Execute configuration applies changes made to the corresponding section only for the local side CFI...

Страница 57: ...tered parameter value or other problems on the whole page the info message is being shown here Otherwise it says Ok Do not make any changes to default route otherwise management connection to CFIP will be lost Additional network configuration commands in Telnet serial interface Command Description net ping ip This command is for troubleshooting purposes to verify the service channel connectivity i...

Страница 58: ... look in the following way Press Execute configuration 2 Enter the local side close end Web GUI and go to IP configuration The configuration will look in the following way Press Execute configuration 3 In MS Windows go to Control panel Network Connections In LAN Properties find Internet Protocol TCP IP and click on its Properties detailed description is in Chapter 2 2 3 Configuration of LAN Ethern...

Страница 59: ...and 2 correspond to optical Ethernet ports 1 and 2 second available for 2 port optical CFIP Lumina Port 3 and 4 correspond to electrical Ethernet ports 1 and 2 second available for 2 port electrical CFIP Lumina Unavailable CFIP Lumina ports appear as N A 3 Port state shows operation status of each port 4 Link shows whether link with appropriate port is established 5 Duplex actual shows if port is ...

Страница 60: ...it says Ok 4 5 Link aggregation and protection 4 5 1 Link aggregation 2 0 and protection 1 1 Link aggregation in 2 0 mode allows utilizing up to 732 Mbps Ethernet Layer 2 throughput 256QAM 56MHz by using independent frequency pair for each link Link protection in 1 1 HSB Hot Stand By mode allows utilizing up to 366Mbps by using single frequency pair for both links Traffic is being balanced 2 0 or ...

Страница 61: ...ses for each CFIP Lumina unit Please see example given in Figure 4 5 6 Remote IP address for all units should be entered manually In order to do that in Tools Command line should be entered modem ipremote off command and afterwards appropriate remote IP address entered in Configuration IP configuration 7 When you have configured both links proceed with 2 0 or 1 1 configuration Figure 4 5 Link aggr...

Страница 62: ...ses in order to force unit to Active state 6 Change state use only for testing purposes in order switch working link 7 Pressing Execute configuration applies changes made to the corresponding section only for the local side CFIP Lumina If Rollback on is selected configuration will be reverted in case of erroneous configuration changes applied 8 Writes to configuration file all the changes made on ...

Страница 63: ...fo message is being shown here Otherwise it says Ok 4 6 VLAN Configuration The VLAN configuration window provides configuration of port based Ethernet Virtual Local Area Networks VLANs allowing using up to 4095 different VLAN IDs It is possible to assign 2 modes to your VLANs Trunk VLAN tagged packets are passed through on egress and ingress directions and Access VLAN tagged packets are untagged o...

Страница 64: ...displays the list of set VLAN IDs and appropriate VLAN types on all available switch ports 7 Select Deselect all VLAN s Allows selecting or deselecting all VLANs of the corresponding port 8 You can delete single VLANs or VLAN ranges by entering preferable VID range and pressing Del button 9 Pressing Execute configuration applies changes made to the corresponding section only for the local side CFI...

Страница 65: ...is connected to Management CPU 4 6 2 Ethernet Switch VLAN Status and Settings Figure 4 7 System without VLANs When VLANs are not used Figure 4 7 user data and management data are not separated either logically or physically When using VLANs Figure 4 8 it is necessary to use external switch These switches add remove VLAN tags per port basis Thus management data and user data have different VLAN tag...

Страница 66: ...6 Ext switch 2 User data MM data Port 1 Port 2 Port 3 VLAN B VLAN A B VLAN B VLAN B VLAN B VLAN A VLAN A VLAN A B Figure 4 9 VLANs and ports membership LAN and WAN ports of Int switch 1 and switch 2 are sending and receiving packets according to VLAN IDs configured and adding VLAN tags for packets outgoing from Management port Additionally VLAN tag is removed at Management P6 port of Switch 1 and ...

Страница 67: ...s Only one VLAN with unique IDs is allowed When adding a different VLAN with the same IDs the old VLAN is deleted also the other types of VLANs Simultaneous use of Access and Trunk Type VLANs on LAN P1 P4 is not allowed After the VLAN table initialization is completed 802 1Q VLAN mode must be enabled WAN P5 allows using only Trunk VLAN Type and Management P6 only Access VLAN Type In order to pass ...

Страница 68: ...in QoS parameters accordingly allowing enabling or disabling QoS 802 1p DiffServ or port based priorities and change priority queuing mode 1 QoS 802 1p enables or disables 802 1p priorities for any available switch port LAN1 2 3 4 WAN or Mng command line ethernet QoS 802 1p enable disable Port map The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide Rev 1 10 SAF T...

Страница 69: ...anges made to the corresponding section only for the local side CFIP Lumina If Rollback on is selected configuration will be reverted in case of erroneous configuration changes applied 8 Writes to configuration file all the changes made on the whole page command line cfg write 9 Execution status in case of error or incorrectly entered parameter value or other problems on the whole page the info me...

Страница 70: ...o specific 802 1p values 2 Pressing Execute configuration applies changes made to the corresponding section only for the local side CFIP Lumina If Rollback on is selected configuration will be reverted in case of erroneous configuration changes applied 3 Writes to configuration file all the changes made on the whole page command line cfg write 4 System returned in case of error or incorrectly ente...

Страница 71: ... command line cfg write 4 System returned in case of error or incorrectly entered parameter value or other problems on the whole page the info message is being shown here Otherwise it says Ok 4 8 Spanning Tree Configuration Implementation of Standard IEEE 802 1D 2004 Spanning Tree Protocol is compatible with Rapid STP and Multiple STP Standard IEEE 802 1Q 2005 as well as having additional capabili...

Страница 72: ...le or Disable STP operation 7 Change between MST instances configuration when MSTP operation mode is enabled Root information displays the data only when STP RSTP MSTP is enabled 8 Regional Root ID displays the Bridge ID for instance 0 of current Root bridge 9 Regional Root Port currently selected root port for instance 0 is being shown 10 Root Path Cost displays the path cost port for instance 0 ...

Страница 73: ...sing Execute configuration changes made to the corresponding section apply only for the local side 20 Write to config file saves to configuration file all the changes made on the whole page command line cfg write 21 System returned in case of error or incorrectly entered parameter value or other problems on the whole page the info message is being shown here Otherwise it says Ok Instance 0 carries...

Страница 74: ...PDUs displays how many topology changing notification BPDUs packets received 5 Bad MSTP BPDUs displays how many bad MSTP BPDUs packets received 6 Bad RSTP BPDUs displays how many bad RSTP BPDUs packets received 7 Bad Conf BPDUs displays how many bad STP BPDUs packets received 8 Bad TCN BPDUs displays how many bad topology changing notifications BPDUs packets received 9 Tx MSTP BPDUs displays how m...

Страница 75: ...terminal with the installed Trap Manager software based on SNMP v1 v2 platform The CFIP Lumina management controller sends SNMP traps to the Trap Manager with IP address specified here The SNMP Trap Manager is a PC with installed SNMP trap management software The default Trap Manager IP address is 255 255 255 255 meaning that no trap packets are sent by the management controller 5 Allows to add or...

Страница 76: ...resses from the list command line snmp host add delete list reset ipaddr and snmp2 host add delete list reset ipaddr 3 Writes to configuration file all the changes made on the whole page command line cfg write 4 System returned in case of error or incorrectly entered parameter value or other problems on the whole page the info message is being shown here Otherwise it says Ok The CFIP Lumina Series...

Страница 77: ... ID Group ID Alarm Event name Description 1 1 System Start Software started Only rising 2 2 Invalid device license License is not valid 3 3 License expired License validity has expired 4 4 License will soon expire License validity will soon expire 5 5 Log was Cleared Entered when Log Clear command was called Only rising 6 6 Log ERROR Log data structure missing 7 7 Log TEST Log test was made 8 8 Co...

Страница 78: ...t of defined range 28 19 No data from RADIO No data from radio for future compatibility 29 20 Rx level alarm Rx alarm level is out of defined range 30 21 Tx PLL error alarm Tx PLL failure 31 22 Rx PLL error alarm Rx PLL failure 32 23 No data from MODEM No data from MODEM connected via UART interface 33 24 Acquire status alarm Modem acquire failure status 34 25 Last acquire error status Modem last ...

Страница 79: ... seen in the table above or using the command alarm list in the command prompt To configure representation of alarms refer to Chapter 5 1 5 Figure 5 2 Alarm status window 5 1 4 Alarm Log To view alarms history go to Performance Alarm log Alarm log shows 21 latest alarm entries per page and about 2000 latest alarm entries in total Alarm entries are mostly distributed in two groups Set when alarm ap...

Страница 80: ...ows you to configure alarm representation You have a choice to see specific alarm groups globally in alarm status Global in alarm log Log or in NMS system SNMP By default all alarms are enabled The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide Rev 1 10 SAF Tehnika JSC 2013 ...

Страница 81: ... levels to bound alarms to desirable values so that you are able to adapt alarm system to your individual needs Alarms in bold font represent group alarms and alarms in normal font individual alarms The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide Rev 1 10 SAF Tehnika JSC 2013 ...

Страница 82: ... log commands display the latest 20 log entries the log entries are numbered entry with the largest number is the latest event The log show command can be followed up with an entry number to display the latest 20 entries beginning from the entry specified by the number e g log show 100 will display entries 100 120 Log filter alarm ID num Filters event list by specific alarm ID start line works sim...

Страница 83: ...t register must be reset Some current register values are passed to the threshold crossing control unit for triggering threshold crossing notification Optionally the same values are output to the Message Communication Function MCF to be forwarded to the managing system Command Description Log file file name Makes event log file with specified filename Alarm stat Lists alarm groups currently set Al...

Страница 84: ...g of each measurement period The TM is therefore composed of two values the minimum and the maximum value Comparison between the current value and the minimum and maximum values is performed on a second basis 5 2 3 Performance Management in Web GUI The main performance management tool in the CFIP Lumina is Web interface allowing user to review performance measurements in a very convenient and visu...

Страница 85: ...f seconds in a chosen period 1min 15min or 1h when the parameter has been out of bounds set by performance thresholds in Configuration Performance log configuration To define thresholds from where TS threshold seconds will be counted you must go to Configuration Performance log configuration and enter preferable threshold values Refer to sections 5 2 1 and 5 2 2 for further details on threshold se...

Страница 86: ...tage and Power consumption and to view their graphs It is possible to choose between 8 scales from 12 last minutes to the maximum of 6 last days to be displayed in the graph It is also possible to choose time period to be displayed defining date and time till which the graph will be shown Figure 5 10 Performance graph showing system temperature and Rx level in period of last 6 hours 1 1 9 5 7 8 6 ...

Страница 87: ...nt 1 for the performance data available If no data is available for the according moment __ __ is shown 11 Legend for the curves of the performance graph Contains the color the name and the unit of measurement if available In case no performance data has been recorded or the period specified has no data No data is shown instead of points 9 10 11 5 2 4 Constellation Diagram A constellation diagram ...

Страница 88: ...re 5 13 Phase noise 4QAM 4 Amplitude compression causes the corner points to move towards the centre Figure 5 14 Amplitude compression 64QAM Examples of CFIP constellation diagrams under excellent conditions are shown below The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide Rev 1 10 SAF Tehnika JSC 2013 ...

Страница 89: ...erference between them In current CFIP device an adaptive equalizer is realized as complex arithmetic 24 taps digital FIR Finite Impulse Response filter In other words equalizer is a selective frequency amplifier and attenuator a device which application to IF Intermediate Frequency band limited signal is schematically shown in the picture below Equalizer graph Equalizer graph window shows adaptiv...

Страница 90: ...ust be inspected with use of precise and accurate path profiling An example of multipath caused equalization is shown on the picture below Taps mainly on the right side designate a weaker reflected signal in comparison with the main signal 5 2 6 Performance Management Commands It is also possible to view performance log in command prompt The list of available commands is the following The CFIP Lum...

Страница 91: ...rt time or date respectively pm select Up_TIME Rx_LEVEL Tx_LEVEL RADIAL_MSE LDPC_STRES MOD_TEMPER SYS_TEMPER PSU_U_IN PSU_POW ALL NOT Allows selecting the system parameters to be monitored and shown in the performance management log pm logclear Clears performance log pm threshold stat auto Rx_LEVEL Tx_LEVEL RADIAL_MSE LDPC_STRES MOD_TEMPER SYS_TEMPER PSU_U_IN PSU_POW min max value auto Sets thresh...

Страница 92: ...s but contained an Unknown Opcode 8 Pause frames frames received are control frames with valid PAUSE opcodes 9 Control frames frames received as control frames 10 Dribble nibbles indicates that following the end of the packet additional 1 to 7 bits are received A single nibble named the dribble nibble is formed but not sent to the system 11 Broadcasts packets which destination address contained br...

Страница 93: ...tes transmitted on the wire including all bytes from collided attempts 31 Underruns underruns occur during frame transmission 32 Giants frames having byte count greater than the MAXIMUM FRAME SIZE parameter 1516 1536 or 1916 bytes 33 Late collisions Collisions occurred beyond the collision window 512 bit times 34 Max collisions packets aborted after number of collisions exceeded the RETRANSMISSION...

Страница 94: ...ount 3 TxOctets The total number of good bytes of data transmitted by a port excluding preamble but including FCS 4 TxDropPkts This counter is incremented every time a transmit packet is dropped due to lack of resources e g transmit FIFO underflow or an internal MAC sublayer transmit error not counted by either the TxLateCollision or the TxExcessiveCollision counters 5 TxQ0PKT The total number of ...

Страница 95: ... is dropped on the flow control 16 TxPausePkts The number of PAUSE events at each port 17 TxQ1PKT The total number of good packets transmitted on COS1 which is specified in MIB queue select register when QoS is enabled 18 TxQ2PKT The total number of good packets transmitted on COS2 which is specified in MIB queue select register when QoS is enabled 19 TxQ3PKT The total number of good packets trans...

Страница 96: ...r does not include errored broadcast packets or valid multicast packets 38 RxSAChanges The number of times the SA of good receive packets has changed from the previous value A count greater than 1 generally indicates the port is connected to a repeater based network 39 RxFragments The number of packets received by a port that are less than 64 bytes excluding framing bits and have either an FCS err...

Страница 97: ...ored from EEPROM during next boot up time Example of script can be observed on the screenshot below The script can be edited string can be added to system configuration script by simply entering required string see Nr 10 on the screenshot below or by executing command in CLI or in the appropriate Web GUI section the script will be supplemented with the new string or the instant string entry will b...

Страница 98: ...load cfg file allows downloading system configuration file and saving it on your hard drive The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide Rev 1 10 SAF Tehnika JSC 2013 ...

Страница 99: ...string which you want to save in cfg allows you to enter desirable command which will be added to running system configuration file as the last line command line cfg add cmdline 11 Load factory configuration file Resets system configuration by loading in EEPROM the script with default settings This command performs the following actions in the following order 1 clears the currently saved system co...

Страница 100: ... specifying data transmission parameters and functionality for specific time period or for unlimited time CFIP without licensing option will operate with full functionality but CFIP with licensing option but without activated licenses will operate with minimum functionality 14 or 20 MHz channel bandwidth depending on model 4QAM modulation no ACM Functionality may be expanded using appropriate lice...

Страница 101: ... status 9 40000 KHz shows the maximum modulation that can be used together with 40 MHz channel bandwidth command line license status 10 50000 KHz shows the maximum modulation that can be used together with 50 MHz channel bandwidth command line license status 11 56000 KHz shows the maximum modulation that can be used together with 56 MHz channel bandwidth command line license status 12 ACM shows if...

Страница 102: ...rough serial telnet interface This dialog box translates commands to Telnet commands and sends them to the device The initial screen shows you the available commands To view help on a command type in command where command stands for the specific command Additional command prompt commands Command Description Cls Clears the screen Help command Provides help messages for commands The CFIP Lumina Seri...

Страница 103: ...t system The flash disk may store other files as well for example previous firmware versions configuration backup files up to 6 5 Mb about 6 firmware files The attribute flags for files are case sensitive The file names can be changed but it is very important that the file has the necessary attribute flags otherwise the file will not be used either as firmware or as boot ini type file There are no...

Страница 104: ...s General tips Telnet server supports one user only web server supports up to 32 users simultaneously By default the username and password for Web server FTP server and Telnet terminal is Username login admin Password changeme The username and password can be changed in Web GUI System configuration User configuration access set username password plaintext command Take note of upper case and lower ...

Страница 105: ...nd login page will appear Besides there are other various ways how the user can update the CFIP management software by uploading the appropriate firmware file to the CFIP Lumina flash disk and further editing boot configuration file if necessary The file upload can be performed via Ethernet management port using update package via Ethernet management port using FTP via Ethernet management port usi...

Страница 106: ...de CFIP Lumina traffic flow won t be interrupted in Configuration System configuration 8 2 File Upload via Ethernet Management Port TFTP Assuming that the CFIP IP settings are properly configured proceed as follows 1 Connect the CFIP to network or directly to PC 2 Make sure TFTP is running on CFIP by default the TFTP is switched off to run TFTP on CFIP connect to CFIP with Telnet client and enter ...

Страница 107: ...o edit boot ini file by deleting the entry with the old file name and to write file name of the new firmware file the boot ini file must be saved with B and e flags file attributes For more information how to edit files please refer to the chapter Working with files in Chapter 6 4 8 3 File Upload via Ethernet Management Port FTP Before uploading file via FTP make sure the CFIP FTP server is runnin...

Страница 108: ...Hyper Terminal program please refer to Chapter 2 3 1 for information how to make a connection 2 Type restartcpu and while CFIP is booting press any key when boot ini prompt appears This will stop executing script in boot ini file and the CFIP will remain in MicroMonitor mode This is the system start up mode which loads the management system firmware Note While you are in MicroMonitor mode the uMON...

Страница 109: ...played Figure 7 2 Figure 7 2 5 Enter reset command to exit from MicroMonitor mode and restart the CFIP 6 Proceed with steps 5 and 6 in Chapter 7 1 The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide Rev 1 10 SAF Tehnika JSC 2013 ...

Страница 110: ...f your PC Ethernet adapter connected to CFIP unit by executing the command ipconfig Navigate to the folder containing previously downloaded and unzipped Discovery Protocol using cd command Now the necessary Discovery Protocol command can be executed e g dp sight scan_addr where scan_addr should be substituted by Ethernet adapter IP address of your PC Discovery Protocol Commands Discovery protocol ...

Страница 111: ...e from the same subnet in order to manage the CFIP unit In the table below some examples are given for CIDR notation and subnet mask relation CIDR notation Network mask 24 255 255 255 0 25 255 255 255 128 26 255 255 255 192 27 255 255 255 224 28 255 255 255 240 29 255 255 255 248 30 255 255 255 252 Note that IP addresses of Ethernet adapter and CFIP units may belong to different subnets This comma...

Страница 112: ...o figure below for example Note that IP address of Ethernet adapter should belong to the same subnet as CFIP units i e the subnet of CFIP units should be known The subnet mask of Ethernet adapter and CFIP units may differ This command sends discovery messages on specified broadcast address to all devices in the specified subnet All CFIP devices from specified subnet are responding with its own IP ...

Страница 113: ... the remote CFIP units known to you Instead of scan_addr place the broadcast address Refer to figure below for example Note that one IP address of remote CFIP units should be known The remote host sends discovery packets to specified broadcast address and the responses are delivered to the local host This allows finding out the IP address and firmware version of neighboring devices of a known remo...

Страница 114: ...ort is DC voltage and varies depending on received signal level The following chart and table shows typical relationship of the received signal level Rx level displayed by CFIP vs RSSI port output voltage RSSI Received Signal Strength Indicator The RSSI port is located on FODU The evaluated Rx level has the error 2 dB Typical RSSI f RSL chart The CFIP Lumina Series Full Outdoor Unit Technical Desc...

Страница 115: ...in BNC Connector Twin BNC connector is used for RS 232 serial port RS 232 USB convector cable can be used Pinouts are shown in picture below Figure 9 3 RS 232 port pinouts pin numbers refer to DB9 female connector Tx Rx 1 Bi directional A 2 Bi directional A 3 Bi directional B 4 Bi directional C 5 Bi directional C 6 Bi directional B 7 Bi directional D 8 Bi directional D The CFIP Lumina Series Full ...

Страница 116: ...r DC power connector can be connected in any preferable layout Figure 9 4 DC power connector pinout 1 2 1 2 The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide Rev 1 10 SAF Tehnika JSC 2013 ...

Страница 117: ...1 2 O ring rubber gasket to be fitted between 0 25m antenna and FODU P N CLAOR001 CLAOR002 RSSI cable for ODU align 1m BNC 2 plug in P N CLGCRS01 CFIP FODU Mounting Bracket for 1xFODU P N CLGRFB05 for 2xFODU P N CLGRFB06 Indoor Power over Ethernet injector P N I0ATPI11 Outdoor Power over Ethernet splitter P N I0ATPS03 The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration...

Страница 118: ...ivator 0 3 0 6 0 99 1 2m antenna for dual pol For further details see Chapter 11 2 AC DC Power adapter 40 50V 1 5 1 2A 63W For further details see Chapter 11 1 ODU twin BNC RG108A connector for RS 232 console port for FODUs P N FOACNT01 Surge protection for CFIP Lumina 48VDC cable 2A P N I0ASP201 CFIP Lumina RJ 45 cable connector case The CFIP Lumina Series Full Outdoor Unit Technical Description ...

Страница 119: ... Test equipment 7 8 GHz P N C08TST02 7 8GHz test suite contains two waveguide to coaxial adapters two attenuators 40 dB coaxial cable 40 cm long Test equipment 10 11 GHz P N C11TST02 Test equipment 10 11 GHz Test equipment 13 15 GHz P N C15TST02 13 15GHz test suite contains two waveguide to coaxial adapters two attenuators 40 dB coaxial cable 40 cm long Test equipment 18 23GHz P N C22TST02 18 23GH...

Страница 120: ... SAF adapted for direct mount to Arkivator 0 3 0 6 0 99 and 1 2m antennas P N Name Description C07WF201 7 8GHz Flexible Waveguide 60cm UBR PBR Flexible Waveguide 2ft 60cm 7 8GHz for connection of ODU to antenna if installed separately for connection between splitter and antenna 1 1 protected installation C07WF301 7 8GHz Flexible Waveguide 90cm UBR PBR 7 8GHz Flexible Waveguide 90cm UBR PBR C11WF30...

Страница 121: ...cs FODU Full Outdoor Unit FTP File Transfer Protocol GFP Generic Framing Procedure GND Ground GUI Graphical User Interface IEEE Institute of Electrical and Electronics Engineers IF Intermediate Frequency ISP Internet Service Provider ITU T International Telecommunication Union Telecommunication Standardization Sector LAN Local Area Network LDPC Low Density Parity Check Code LED Light Emitting Diod...

Страница 122: ...M Time Division Multiplexing TFTP Trivial File Transfer Protocol TM Tide Mark TP Twisted Pair TS Threshold Seconds Tx Transmission UART Universal Asynchronous Receiver Transmitter USB Universal Serial Bus VLAN Virtual Local Area Network WAN Wide Area Network The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide Rev 1 10 SAF Tehnika JSC 2013 ...

Страница 123: ...hnika A S technical support can be reached by Email techsupport saftehnika com Telephone 371 67046840 Fax 371 67046809 The CFIP Lumina Series Full Outdoor Unit Technical Description and Configuration Guide Rev 1 10 SAF Tehnika JSC 2013 ...