Installation:

This light should be installed at minimum 250-300mm (10-12”) below the light load water line with approximately a 20° down angle
by qualified/approved personnel using proper tools, welding procedures and materials. An access area of at least 75mm (3”)
should be left behind the light for servicing and general ventilation.
After selecting a location, cut an appropriate sized hole through the vessel hull. Note: Hole size will be defined by the specific weld-
in Front Flange (18) that came with the light. Caution! Check that no electrical wiring, fuel lines, oil lines, water lines etc., pass
near or through the intended hole location. Note: In order to allow proper heat dissipation from the installed lights it is important
to ensure that any hull insulation/cladding is not in contact with the thru hull or light body. It is recommended that a minimum of
30mm (1.2”) of clear space should be surrounding the fixture to allow for adequate cooling.
Place the supplied Front Flange (18) into said hole and following common ship building practices, permanently weld-in place. Note:
Leave the factory installed block-off disk and protective cap on the supplied Front Flange (18) until final light assembly.
Final light assembly - Remove Front Flange (18) block-off disk, protective cap and clean all surfaces. Install two Glass Gaskets (5)
(one gasket on either side of glass) Glass (4), Glass Retaining Ring (3) and six fasteners (13) tightened in a criss-cross pattern to 9
Nm (7 ft/lbs) using a 5mm allen wrench. Screw Connecting Ring (2) with attached Main Body (1) onto Front Flange (18) and
tighten to 40 Nm (30 ft/lbs). Note: Apply anti-seize compound to Connecting Ring (2) threads. Upon making proper electrical
connections (see driver box manual), connect Receptacle (16) to plug (17). Note: Upon completing light installation, it is highly
recommended that the Front Flange (18) be coated with antifouling paint.

Serviceable Parts:

This light is fully serviceable and all parts are replaceable. Please contact our technical support staff to discuss your individual
needs.
For Glass (4) replacement, disconnect Receptacle (16) from Plug (17), remove Connecting Ring (2) with attached Main Body (1),
remove six fasteners (13), Glass Retaining Ring (3) and Glass Gaskets (5). Upon thoroughly cleaning all surfaces, reverse said
procedure to assemble the new Glass (4) and Glass Gaskets (5). Note: Tighten all six fasteners (13) in a criss-cross pattern to 9
Nm (7 ft/lbs) using a 5mm allen wrench.

Caution! Never attempt to remove/replace Glass (4) while vessel is in the

water.

MODELS B15_12A41-12G32L, 120/230VAC (STEEL)

MODELS B15_10A41-12G32L, 120/230VAC (ALUMINUM)

BALLOON

PART

DESCRIPTION

1

14323

MAIN BODY / COFFERDAM

2

14002

CONNECTING RING

3

14004

GLASS RETAINING RING

4

14007

GLASS

5

14008

GLASS GASKET

6

14009

CONNECTING RING GASKET

7

14310

LED ARRAY

8

14321

THERMOSWITCH

9

14305

CABLE STRAIN RELIEF

10

14306

ELECTRICAL CABLE

11

14015

M6 x 1.0 x 14LG SST SHCS

12

14320

SILICONE LENS

13

14319

LENSE HOLDER

14

14322

M7 x 0.7 x 8LG SST PPHS

15

14307

M3 x 0.5 x 5LG SST PPHS

16

14316

RECEPTACLE ASSEMBLY, 2-WAY

17

14317

PLUG ASSEMBLY, 2-WAY

18

N/A

CALL TECHNICAL SUPPORT FOR     

APPROPRIATE FRONT FLANGE

SV14 LED Light

Underwater Lights USA, LLC

Underwater Lights Europe Sarl

3406 S.W. 26

th

Terrace, C 6/7

16, rue Rouaze

Fort Lauderdale, FL 33312 USA

06400 Cannes, France

Phone: 1-954-760-4447

Phone: 33-(0)-4-97-21-02-96

Fax: 1-954-525-3261

Fax: 33-(0)-4-97-21-10-96

Internet: www.seavision.com

Internet: www.seavision.com

Email: [email protected]

DOC:022412-4

Email: [email protected]

STEEL/ALUMINUM

Reviews: