the   lifting   tool.      Remove   the   foot   valve   and   inspect   the   inlet   screen.      Clean   any   debris   
that   may   have   collected   in   the   bottom   of   the   foot   valve   filter   screen.         

   

8.2   Re-­‐Assembling   the   Sprinkler   

Prior   to   re-­‐assembling   the   sprinkler,   flush   the   sub-­‐lateral   line   thoroughly.      Securing   the   
upper   and   lower   portions   of   the   sprinkler   body   with   the   fasteners   and   using   the   special   
flushing   tool   p/n   RZG2   17623   (shown   as   31   in   the   Figure   8-­‐1   below),   can   accomplish   this   
task.      
   

   

   
   

   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   

   
   
   
   
   
   
   
   

   

Mirage   M-­‐125   /   M115   Flushing   Tool   

Figure   8-­‐1   

   
1)

 

Locate   the   foot   valve   and   thread   into   the   valve   sleeve   tool   p/n   RZK2   17623.      Insert   into   
the   lower   sprinkler   body   with   the   chamfered   surface   pointing   downward.      Grease   the   
rubber   edges   to   ease   of   insertion.         

2)

 

Align   the   valve   insert   with   manual   control   device   or   ventilating   screw,   as   the   foot   valve   
is   set   into   place.      This   may   require   some   slight   downward   blows   with   the   sleeve   tool   to   
seat   into   place.         

3)

 

Replace   the   retaining   snap   ring   by   placing   into   the   groove   with   the   snap   ring   tool   p/n   
RTC4   17839.      If   the   snap   ring   will   not   seat   properly,   confirm   the   foot   valve   is   seated   
properly.      This   may   require   the   foot   valve   to   be   removed   and   re-­‐seated.      

4)

 

Align   the   impact   drive   subassembly   with   its   guide   pins   in   any   small   groove.      Press   into   
place   and   secure   with   the   stainless   steel   fasteners.   Tighten   in   a   star   pattern   to   set   to   
secure   properly.      

 

Summary of Contents for Mirage M-125

Page 1: ...M 125 M 115 Operating and Maintenance Instructions Underhill International Corporation 20505 Crescent Bay Drive Lake Forest CA 92630 Phone 949 305 7050 Fax 949 305 7051 www uicorp net www underhill us...

Page 2: ...1 DEFINITION OF SYMBOLS 3 2 2 DANGER IF SAFETY INSTRUCTIONS ARE NOT OBSERVED 4 3 0 DESCRIPTION 4 4 0 INSTALLATION 4 5 0 COMMISSIONING 4 6 0 WINTERIZING 5 7 0 MAINTENANCE 5 8 0 INSPECTION AND DISASSEM...

Page 3: ...ull 3600 or part circle to a minimum of 300 The Mirage M 125 M 115 can be applied in both synthetic and natural turf applications Both products have a 1 1 2 BSP inlet threads and can be mated with Und...

Page 4: ...provided PVC or ductile iron swing joint assembly 5 Once the sprinkler head is installed set vertically and to adjacent finish grade Make the wire connections for valve in head models using approved...

Page 5: ...ater can be flushing from the solenoid plunger chambers 4 During the winter it is recommended to activate the solenoid for about 1 minute 2 times a week 7 0 Maintenance 1 Clean the interior cavity of...

Page 6: ...Mirage M 125 M 115 Operating Maintenance Instructions 6 M 125 M 115 Sprinkler Subassemblies Figure 6 1 1 2 3 5 4 6 7...

Page 7: ...s threaded plate to the side 2 Locate and unscrew the slotted head fasteners that secure the impact drive assembly to the lower portion of the sprinkler body Set the fasteners to the side and carefull...

Page 8: ...the valve sleeve tool p n RZK2 17623 Insert into the lower sprinkler body with the chamfered surface pointing downward Grease the rubber edges to ease of insertion 2 Align the valve insert with manua...

Page 9: ...impact drive assembly are set to arc pattern desired 6 Place the brass threaded plate and secure the top lid to the plate using the 2 qty Allen head fasteners 7 Operate the re assembled sprinkler eit...

Page 10: ...is inadequate De pressurize the mainline or sub lateral piping before attempting the last two possible root causes The solenoid is defective The plunger in the solenoid is stuck in the up position Re...

Page 11: ...compressed air blow the control pipe backwards to remove any clogged debris 3 Sprinkler will not turn off manually De pressurize the mainline or sub lateral piping before attempting the last two poss...

Page 12: ...possible root causes The bottom inlet filter is clogged with debris Verify delivery pressure with a Pitot tube and pressure gauge while the sprinkler is operating Is the operating pressure matching t...