![Uncle Albert's UAD-300 Quick Start Manual Download Page 3](http://html.mh-extra.com/html/uncle-alberts/uad-300/uad-300_quick-start-manual_838220003.webp)
· Switch 10 “ON” = # 1on the UAD·300.
· Switch 11 “ON” = #2on the UAD·300.
· Switch 12 “ON” = # 3on the UAD·300.
Set the switch "ON" for the message you want played.
NOTE: Whichever switch is set in the "ON" position, the two remaining switches must be turned "OFF".
Example: Switch 11 "ON", Switches 10 and 12 "OFF", the UAD· 300 will play Message #2 when activated. (see Recording and Erasing
Messages)
Repeat this for each extra UAT·1000 transmitter being used
Replace back cover on UAT·1000 and replace screw.
Learning Mode: UAT-100 to UAD-300
The following procedure will allow your UAT·1000 transmitter to communicate to your UAD·300 auto-dialer.
1
Press TEST on the UAD·300
2
Press (9) on the UAD·300
3
Press TEST on the UAD·300, you will hear one (1) long beep, and the green LED will flash
4. Touch the two contacts on the front of the UAT·1000 transmitter or across the silver sections of the sensor pad (you might have to
wet your finger), you will hear one (1) short beep, and the green LED will glow steadily.
5. Press CLR on the UAD-300.
6. Repeat this procedure for any additional UAT·1000 transmitters
Connecting the Remote Sensor
• Plug the molded end plug of the remote sensor into the two (2)
contacts on the front of the UAT·1000.
Mounting UAT·1000 Transmitter/Sensor
NOTE: Every home and business is going to be different, there are a few things to keep in mind when installing your transmitters:
●
The UAT·1000 is not waterproof, it must be mounted in a dry area.
●
The sensing pad circuit board must be placed in an area where it will come in contact with
UNWANTED water (ie: the lowest point on the laundry room floor, close to a basement drain,
or the top of a sump pump pit)
If false alarms become a problem in a high humidity area it might
be necessary to cut the silver pad off and use bared wire ends as the sensor.
●
You can use as many UAT·1000s as needed to monitor an area.
●
AS WITH ALL RADIO FREQUENCY DEVICES, TRANSMISSION
RANGE AND RECEPTION MAY VARY.
Mounting for Sump pump:
1. Using a cable tie, mount the circuit board pick-up to the sump outlet pipe.
Place it at a level just below the basement floor.
2 Using a cable tie, mount the UAT·1000 transmitter to the
sump outlet pipe, pull all of the slack out of the remote sensor cable
3. Cable tie the remote sensor cable to the sump outlet pipe
If false alarms become a problem in a high humidity area it might
be necessary to cut the silver pad off and use bared wire
ends as the sensor
.
Mounting for washing machine:
1. Using a cable tie, mount the UAT·1000 transmitter to one
of the washer hoses.
2. Place the circuit board pick-up on the floor behind the washer.