LIST OF PRODUCT: 

 

SAL 35

 v.230/50-60Hz - v.400 ~/50-60Hz. - v.400 3~/50Hz.

 v.115/50Hz - v.48 ~/50Hz. - v.48 3~/50Hz. - v.460 ~/50Hz

SAL 40

 v.230/50-60Hz - v.400 ~/50-60Hz. - v.400 3~/50Hz.

 v.115/50Hz - v.48 ~/50Hz. - v.48 3~/50Hz. - v.460 ~/50Hz

SAL 45

 v.230/50-60Hz - v.400 ~/50Hz. - v.400 3~/50Hz.

SAL 80-80A

 v.230/50-60Hz - v.400 ~/50Hz. - v.400 3~/50Hz.

                               

 

CE  DECLARATION OF CONFORMITY 

 

 

 

 

 

 

                                                        MAGIONE 03/02/2021 

                                                        UMBRAPOMPE SRL 

                                                       I

l Legale Rappresentante 

 
 
 

 

UKCA  DECLARATION OF CONFORMITY 

 

The company Umbra Pompe Srl, Via G.Matteotti 16, Magione (PG) 

– Italy 

declared the above menthioned products comply with: 

 

-  Supply of Machinery (Safety) Regulations 2008; 

-  Electrical Equipment (Safety) Regulations 2016; 

-  Electromagnetic Compatibility Regulations 2016; 

-  RoHS, WEEE, REACH 

   

 

Harmonized Standards: 

BS EN 60335-1, BS EN 60335-2-41, BS EN 55014-1; - 2 BS EN 61000-3-2; -3-3 

           

 
 

                                                       MAGIONE 03/02/2021 

                                                        UMBRAPOMPE SRL 

                                                       

Legal Representative 

 

 

 

(GB) CONFORMITY DECLARATION

 

The Company Umbra Pompe Srl - Via G.Matteotti 16, Magione (PG) - Italy,

 

Declared that the above-mentioned products comply with:

 

2006/42/CE, LVD (2014/35/CE), EMC (2014/30/CE), RoHS (2015/863 UE),

 

RAEE (2012/19/CE),   Reg. REACH (1907/2006),   

 

Armonized Standards: CEI EN 60335-1, 60335-2-41, EN 55014-1, EN 55014-2 EN 61000-3-2; 3-3 

(I) DICHIARAZIONE DI CONFORMITA'

 

La Società Umbra Pompe Srl - Via G.Matteotti 16, Magione (PG) - Italia,

 

dichiara che i prodotti summenzionati sono conformi a:

 

2006/42/CE, LVD (2014/35/CE), EMC (2014/30/CE), RoHS (2015/863 UE),

 

RAEE (2012/19/CE),   Reg. REACH (1907/2006),   

 

Norme armonizzate CEI EN 60335-1, 60335-2-41, EN 55014-1, EN 55014-2 EN 61000-3-2; 3-3 

Summary of Contents for SAL 35

Page 1: ...SAL 35 40 45 MANUALE D ISTRUZIONE I OPERATING INSTRUCTIONS GB...

Page 2: ...e in the country where the products is installed As additional protection against lethal electric shock install an high sensitivity differential switch 0 03A For connection to the mains use a multiple...

Page 3: ...anufacturer to avoid impeller blockages In the SAL 35 self priming version the body pump must only be positioned with the suction and delivery upwards 4 TRANSPORT MANAGEMENT AND DISPOSAL 4 1 Transport...

Page 4: ...The proper direction of rotation corresponds to the type of operation that ensures greater delivery Do not operate the pump in the opposite direction of rotation any longer than 2 3min 6 INSTALLATION...

Page 5: ...of the pump component This operation is also raccomended in case of prolonged inactivity of the pump at normal temperature If the pump has been used with substances that tend to deposit rinse it afte...

Page 6: ...Contact the supplier to replace it c Check the sense of rotation and eventually invert it 4 PUMP DOESN T STOP a The supply switch is defective a Replace it 5 INTERMITTENT OPERATION a The pump is partl...

Page 7: ......

Page 8: ...izzatore non deve eseguire di propria iniziativa alcun intervento Decliniamo ogni responsabilit nella mancanza dell osservanza di quanto riportato nel presente manuale L utilizzo consentito solamente...

Page 9: ...Le elettropompa non deve funzionare in assenza di acqua per evitare il danneggiamento della tenuta meccanica L elettropompa non pu essere utilizzata in piscine stagni o bacini con presenza di persone...

Page 10: ...po Y secondo la norma CEI EN 60335 2 41 pertanto eventuali danni richiedono la sostituzione e non la riparazione dello stesso Nel caso di danneggiamento del cavo di alimentazione esso deve essere sost...

Page 11: ...lle prime fasi di funzionamento della pompa Le perdite dovrebbero risolversi nel giro di breve Qualora ci non accadesse consultare il capitolo 12 Possibili avarie motivi e soluzioni 7 2 Arresto Interr...

Page 12: ...assistenza per la sostituzione c Verificare che il senso di rotazione sia rispettato ed eventualmente invertirlo 4 LA POMPA NON SI ARRESTA a L interruttore di alimentazione difettoso a Sostituire l in...

Page 13: ...DIMENSIONS INGOMBRI CUNFIGURATIONS CONFIGURAZIONI...

Page 14: ...40 230 50 60 220 1 1 6 3 1 4 40 32 22 10 0 SAL 40 400 mono 50 60 230 0 8 5 1 4 40 32 22 10 0 SAL 40 400 trifase 50 200 0 7 1 4 40 32 22 10 0 SAL 40 115 50 230 2 8 20 1 4 40 32 22 10 0 SAL 40 48 mono 5...

Page 15: ...mpatibility Regulations 2016 RoHS WEEE REACH Harmonized Standards BS EN 60335 1 BS EN 60335 2 41 BS EN 55014 1 2 BS EN 61000 3 2 3 3 MAGIONE 03 02 2021 UMBRAPOMPE SRL Legal Representative GB CONFORMIT...