Service Manual
5. Environment vs. Performance
What’s in this Chapter:
•
Overview
•
Shock and Vibration
•
Temperature
•
Humidity
•
Dust
•
Aging
Overview
The
Astra 1220U
offers excellent performance, but, (as with other high end products), in a limited range of
environments.
Astra 1220U
performance drops, and perhaps will fail, under adverse environmental
conditions. For correct diagnosis of malfunctions, it is important to understand the relationship between
environment and performance.
Shock and Vibration
The image sensing unit (chassis assembly) is precisely aligned by several adjustment procedures. This
guarantees maximum resolving power. This component is especially sensitive to shock and vibration. If the
scanner is unintentionally dropped, as may occur in the shipping process, the drop could cause some of the
optical components to become misaligned. Misalignment has a negative effect on the Modulation Transfer
Function (MTF) of the optical system. The following information might be useful in correcting a problem
caused by misalignment:
Make sure all the screws on the optical assembly are tight and all of the optical components
are firmly secured in their respective locations to avoid the dislocation of components such
as the optical assembly's guide shaft.
Temperature
Significant changes in temperature can cause thermal expansion. Under severe conditions, permanent
damage can be done because of irreversible changes in the physical properties of certain materials. For
example, the timing belt loses its creep resistance at temperatures below -40 degrees centigrade. After it
has reached this point, the belt will usually lengthen. The following information should be helpful to you in
maintaining the
Astra 1220U
:
1. Never expose the scanner to temperatures above 50 degrees centigrade or below -40 degrees centigrade.
2. Operation of the
Astra 1220U
in a low temperature situation could produce the following phenomena:
a. dim lamp
b. rough chassis assembly movement
c. unusually loose timing belt
29
Summary of Contents for Astra 1220U
Page 1: ...Astra 1220U Color Scanner Service Manual UMAX Data Systems Inc 0898 e...
Page 4: ...Pin Assignment 44 iv...
Page 14: ...Service Manual AD Pin Assignment 10...
Page 15: ...Service Manual Motor and To CCD Board Pin Assignment 11...
Page 16: ...Service Manual Power Code Pin Assignment 12...
Page 17: ...Service Manual EPP to USB Bridge Pin Assignment 13...
Page 19: ...Service Manual 3797P 15...
Page 37: ...Service Manual Appendix B Scanner Outline Diagram 312 83 98 471 33...