02
0.1
Checks When Opening Packaging
Check the following after opening the packaging.
(1) Whether the pump accords with requirement?
(2) Are the accessories and necessary parts included?
Standard accessories
・
Instruction manual
-------------------- x 1
・
Rubber plug (Inlet / Outlet Port)
-------------------- x 2
・
Rubber leg
-------------------- x 4
・
Screw (For rubber leg fixation)
-------------------- x 4
(3) Is the pump damaged in any way?
(4) Are any external screws or inlet and outlet pipes loose? Are any components missing?
Contact your agent or the sales division of the manufacturer if there are any problems with the
pump.
1. When take out a pump from a packing box, Do not grip the pipe of the upper of the pump.
In addition, please do not do an act bending by pushing.
A pipe is damaged, and pump performance decreases.
2. Always remove the rubber plug from Inlet / Outlet Port before using the pump.
3. Fit an inlet filter if there is a possibility of foreign matter or dust particles entering the pump.
4. Use ventilation holes, and fit a cooling fan, to reduce the temperature in the vicinity of the
pump. Ensure that the pump cooling fan inlet is not blocked. Ensure that a space of at
least 100mm is available on all sides of the pump.
5. Please attach a silencer to suppress the operating sound.
DOP-181S
Pipe
!
Note