3. Installation and Storage
3.1 Cautions for Installation and Storage
See "Warning" (1), (2), (3), (4), (6), (7),
(8), (9), (10), (11), (12), (13), (14) and
(15) on p.04 and P.05.
See "Caution" (1), (2) and (3) on p.05
and P.06
See "Note" (1), (2), and (3) on p.07.
3.2 Environmental Conditions for Installation, Storage, and Operation
The fine clearances used in this pump require that the following conditions be satisfied during
storage, installation, and operation.
(1) Operating altitude less than 1,000m.
(2) Ambient temperature during operation : Ambient temperature range of product
specification .(refer to table1-1)
(3) Ambient humidity of 85% or less during operation
(4) Other conditions (during storage and operation)
a) Level floor of sufficient strength
b) No condensation
c) Dust-free environment
d) Well ventilated
e) Environment free of corrosive or explosive gas
f) Not subject to direct sunlight
g) No danger of fire
h) Do not exceed the maximum ambient temperature of the temperature range of
product specification at the time of pump installation. (refer to table1-1)
i) Sufficient space is available on all sides of the pump, and the pump cooling fan inlet
is not blocked.
3.3 Location
The pump should be installed level in a location with minimal dust and humidity.
This location should be selected in consideration of ease of installation and removal,
inspection, and cleaning.
When it incorporates a pump in equipment, please do not disturb the ventilation of the cooling
fan. Particular attention should be paid to ambient temperature when fitting the pump to
equipment.
Use anti-vibration rubbers to isolate the pump from vibrations in the equipment.
When it locks a pump to the direct equipment parts,
The touch circumference stress of the
pump opmoving element amplifies.
Therefore, it may cause an early trouble in a bearing and
!