ULVAC CRYOGENICS INCORPORATED

     

Band Heater 

(Silicon Rubber Heater)

Instruction Manual

Export Control Policy 

We recommend that ALL customers be sure to follow all 
rules and regulations such as Foreign Exchange and 
Foreign Trade Law when exporting or reexporting our 
products. 

Summary of Contents for Band Heater

Page 1: ...RATED Band Heater Silicon Rubber Heater Instruction Manual Export Control Policy We recommend that ALL customers be sure to follow all rules and regulations such as Foreign Exchange and Foreign Trade...

Page 2: ......

Page 3: ...where our product is used The personnel are also required to have specialized knowledge skills and qualification on the electricity the machinery the cargo handling and the vacuum Especially the perso...

Page 4: ...wns resulting from using the product outside the specified specifications of the product Breakdowns due to contamination or corrosion caused by user s use conditions Breakdowns due to natural disaster...

Page 5: ...splay Serial No Option Part Model Optional Part Serial No 4 Notes for repair and maintenance requests We may decline your request for the repair or the maintenance of our products if you refuse to giv...

Page 6: ...fer this instruction manual or any of its parts to a third person without written permission from ULVAC CRYOGENICS 2 Information in this document might be revised without a previous notice for the spe...

Page 7: ...ould result in severe injury or loss of life A caution describes safety hazards or unsafe practices which could result in personal injury or equipment damage Toxic gas or chemicals used There is a ris...

Page 8: ...F 6 ULVAC CRYOGENICS INCORPORATED This page intentionally left blank...

Page 9: ...onal and local laws and regulations We provide Safety Data Sheet SDS of our products upon your request Please contact us if necessary WARNING The cryopumps or cryocoolers may contain residue of hazard...

Page 10: ...IW 2 ULVAC CRYOGENICS INCORPORATED This page intentionally left blank...

Page 11: ...Characteristic 2 4 Operating Life 2 5 Connector Specifications 2 6 Installation 3 7 Operation 3 8 Troubleshooting 5 FIGURES TABLES Figure 1 Standard drawing 1 Figure 2 Standard temperature property 2...

Page 12: ...Band Heater for CRYO U 22P 1 Instruction Manual ULVAC CRYOGENICS INCORPORATED This page intentionally left blank...

Page 13: ...s also available with silicon sponge insulation 5mm or 10mm It is possible to design together with the form of the case 2 Specifications Table 1 Electricity specifications Specifications Rated Voltage...

Page 14: ...over when there is junction failure in the switching operation unit bimetal of the thermostat This is a high reliability product with a nominal 100 thousand switches possible However the operating lif...

Page 15: ...ee solder on the soldered portion Do not use together with lead solder This heater is made by covering the heating element nichrome wire with a silicon rubber sheet Do not cut or perform hole drilling...

Page 16: ...ing Compared to temperature increase conducted by injecting inert gas in atmospheric pressure in the event that temperature is increased in a vacuum it may take extra time as the heating is done solel...

Page 17: ...ch it should not be used If it freezes more frequent regeneration or reconsideration of heater specification is needed Insulation failure and dangerous Do not use Heater unit replacement is required D...

Page 18: ...Band Heater Silicon Rubber Heater Instruction Manual 6 ULVAC CRYOGENICS INCORPORATED This page intentionally left blank...

Page 19: ...Chigasaki Kanagawa 253 0085 Japan Sales Tel 81 467 85 8884 Service Engineering Division Tel 81 467 85 9366 Fax 81 467 83 4838 ULVAC CRYOGENICS KOREA INC www ulvac cryo co kr 107 Hyeongoksandan ro Che...

Page 20: ...CS 2 ULVAC CRYOGENICS INCORPORATED This page intentionally left blank...

Page 21: ...13 05 15 2013 09 26 2013 12 02 2018 03 06 2019 02 04 2013 05 2013SR01 2013DR02 2018MH03 2019FY04 First edition Introduction has been revised Contact information of Osaka office has been revised in Ser...

Page 22: ...Revision History R 2 ULVAC CRYOGENICS INCORPORATED This page intentionally left blank...